- home
- Advanced Search
- Energy Research
- Open Access
- Closed Access
- Restricted
- Open Source
- 7. Clean energy
- GB
- FR
- CA
- Energy Research
- Open Access
- Closed Access
- Restricted
- Open Source
- 7. Clean energy
- GB
- FR
- CA
description Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Siddig Omer; Elamin Mohamed; Rami Zeinelabdein; Rami Zeinelabdein;© 2020 Elsevier Ltd Free cooling of buildings uses the nocturnal outdoor air as a heat sink via a ventilation process. This could be performed by storing the night coolness for use during the daytime as appropriate. Due to the latent heat capacity, phase change material (PCM) could play anessential role in the effective operation of the free cooling systems by shifting the daytime peak load to the night. However, there is a scarceness on the technology application in hot climates. This paper presents results of a parametric investigation into the application of PCMs as thermal energy storage (TES) to provide sustainable cooling to buildings in hot arid climate by making use of the night-time free cooling. The proposed TES medium comprises an arrangement of metallic modules filled with RT28HC PCM. Numerous geometrical configurations and operational parameters have been assessed. A transient CFD simulation has been employed using ANSYS Fluent software. Validation of the numerical results with experimental data has shown a good agreement. The results have demonstrated that the temperature difference between the PCM and the air, at appropriate air flow rate would have a significant impact on the performance of the system. A free cooling system based on the proposed arrangement has the potential to meet around 42% of a typical building cooling load and has the ability to save up to 67% of building cooling energy load in summer season compared to conventional air-conditioning systems in hot arid climates.
Journal of Energy St... arrow_drop_down Journal of Energy StorageArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.est.2020.101972&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 26 citations 26 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Journal of Energy St... arrow_drop_down Journal of Energy StorageArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.est.2020.101972&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV Ahmed, Asam; Ge, Tianshu; Peng, Jinqing; Yan, Wei-Cheng; Tee, Boon Tuan; You, Siming;Decarbonizing the building sector is extremely important to mitigating climate change as the sector contributes 40% of the overall energy consumption and 36% of the total greenhouse gas emissions in the world. Net-zero energy buildings are one of the promising decarbonization attempts due to their potential of decreasing the use of energy and increasing the total share of renewable energy. To achieve a net-zero energy building, it is necessary to decrease the energy demand by applying efficiency enhancement measures and using renewable energy sources. Net-zero energy buildings can be classified into four models (Net-Zero Site Energy buildings, Net-Zero Emissions buildings, Net-Zero Source Energy buildings, and Net-Zero Cost Energy buildings). A variety of technical, financial, and environmental factors should be considered during the decision-making process of net-zero energy building development, justifying the use of multi-criteria decision analysis methods for the design of net-zero energy buildings. This paper also discussed the contributions of renewable energy generation (hydropower, wind energy, solar, heat pumps, and bioenergy) to the development of net-zero energy buildings and reviewed its role in tackling the decarbonization challenge. Cost-benefit analysis and life cycle assessment of building designs were reviewed to shape the priorities of future development. It is important to develop a universal decision instrument for optimum design and operation of net-zero energy buildings.
CORE arrow_drop_down CORE (RIOXX-UK Aggregator)Article . 2022License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111755&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 263 citations 263 popularity Top 1% influence Top 1% impulse Top 0.1% Powered by BIP!
more_vert CORE arrow_drop_down CORE (RIOXX-UK Aggregator)Article . 2022License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111755&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 CanadaPublisher:Elsevier BV Authors: Hassan Z. Al Garni; Hassan Z. Al Garni; David Wright; Anjali Awasthi;Abstract This paper uses research-quality, ground measurements of irradiance and temperature that are accurate to ±2% to estimate the electric energy yield of fixed solar modules for utility-scale solar power plants at 18 sites in Saudi Arabia. The calculation is performed for a range of tilt and azimuth angles and the orientation that gives the optimum annual energy yield is determined. A detailed analysis is presented for Riyadh including the impact of non-optimal tilt and azimuth angles on annual energy yield. It is also found that energy yield in March and October are higher than in April and September, due to milder operating temperatures of the modules. A similar optimization of tilt and azimuth is performed each month separately. Adjusting the orientation each month increases energy yield by 4.01% compared to the annual optimum, but requires considerable labour cost. Further analysis shows that an increase in energy yield of 3.63% can be obtained by adjusting the orientation at five selected times during the year, thus significantly reducing the labour requirement. The optimal orientation and corresponding energy yield for all 18 sites is combined with a site suitability analysis taking into account climate, topography and proximity to roads, transmission lines and protected areas. Six sites are selected as having high suitability and high energy yield: Albaha, Arar, Hail, Riyadh, Tabuk and Taif. For these cities the optimal tilt is only slightly higher than the latitude, however the optimum azimuth is from 20° to 53° west of south due to an asymmetrical daily irradiance profile.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2018.10.048&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 89 citations 89 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2018.10.048&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2005Publisher:Elsevier BV Jenny M. Jones; R.I. Backreedy; Lin Ma; Alan Williams; Mohamed Pourkashanian; L. M. Fletcher;Abstract A CFD modelling study has been undertaken to examine the co-firing of pulverised coal and biomass with particular regard to the burnout of the larger diameter biomass particles. Computations were based on a research combustion facility that replicates an industrial coal-fired power station. Three percent, by mass, of pinewood was blended with a bituminous UK coal, and the effects of the wood particle size and shape on the burnout of the combined wood and coal char were investigated. The effect of varying the devolatilisation and char combustion rate constants for the biomass component in the blend was also investigated. It was concluded that the combustion of small (200 μm) wood particles was rapid but the rate of combustion of larger particles was dependent on their composition, size, and shape.
Proceedings of the C... arrow_drop_down Proceedings of the Combustion InstituteArticle . 2005 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.proci.2004.08.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu131 citations 131 popularity Top 10% influence Top 1% impulse Top 10% Powered by BIP!
more_vert Proceedings of the C... arrow_drop_down Proceedings of the Combustion InstituteArticle . 2005 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.proci.2004.08.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014Publisher:Elsevier BV Authors: Juntao Zhou; Shunqi Pan; Roger Alexander Falconer;The Severn Estuary has the world's second largest tide range and a barrage across the estuary, located just seawards of Cardiff in Wales and Weston in the South West England, has been proposed for over half a century, with the objective of extracting large amounts of tidal energy. A Severn Barrage, as previously proposed by the Severn Tidal Power Group (STPG), would be the largest renewable energy project for tidal power generation in the world, if built as proposed, and would generate approximately 5% of the UK's electricity needs. However, concerns have been raised over the environmental impacts of such a barrage, including potential increase in flood risk, loss of intertidal habitats etc. In addressing the challenges of maximizing the energy output and minimizing the environmental impacts of such a barrage, this research study has focused on using a Continental Shelf model, based on the modified Environmental Fluid Dynamics Code (EFDC) with a barrage operation module (EFDC_B), to investigate both the far and near field hydrodynamic impacts of a barrage for different operating scenarios. Three scenarios have been considered to simulate the Severn Barrage, operating via two-way generation and using different combinations of turbines and sluices. The first scenario consisted of 216 turbines and 166 sluices installed along the barrage; the second consisted of 382 turbines with no sluices; and the third consisted of 764 turbines and no sluices. The specification of the sluice gates and turbines are the same for all scenarios. The model results indicate that the third scenario has the best mitigating effects for the far-field and near-field flood risks caused by a barrage and produces the most similar results of minimum water depth and maximum velocity distributions to those obtained from simulating the natural conditions of the estuary, i.e. the current conditions. The results also show that the flow patterns around the barrage are closest to those for the existing natural conditions with minimal slight changes in the estuary. Thus, the results clearly indicate that the environmental impacts of a Severn Barrage can be minimized if the barrage is operated for two-way generation and under the third scenario. Although it appears that the energy output for the third scenario is less than that obtained for the other two scenarios, if very low head (VLH) turbines are used, then the third scenario could generate more energy as more turbines could be cited along the barrage structure. Therefore, the study shows that a Severn Barrage, operating in two-way generation and with 764 turbines (ideally VLH turbines), would be the best option to meet the needs of maximizing the energy output, but having a minimal impact on environmental changes in the estuary and far-field.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2014.07.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu16 citations 16 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2014.07.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2010Publisher:Oxford University Press (OUP) Authors: Hao Liu; Guoquan Qiu; Yingjuan Shao; Saffa B. Riffat;doi: 10.1093/ijlct/ctq006
Biomass plays an important role in the world primary energy supplies, currently providing ∼14% of the world's primary energy needs and being the fourth largest contributor following coal, oil and natural gas. Over the past decade, domestic biomass heating has received more governmental and public supports than ever before in many developed countries, such as the UK. Although biomass combustion releases some combustion pollutants, biomass is renewable and produces little net CO 2 emissions to the atmosphere. Owing to the low sulphur and low nitrogen contents of many biomass materials, substituting biomass for fossil fuels, particularly coal, can reduce SO x and NO x emissions. This study investigated flue gas emissions, particularly carbon monoxide and nitrogen oxides, of a domestic biomass boiler under various operating conditions. The biomass boiler used in this study satisfies the current EU regulation (EN 303-05) on emissions of domestic biomass boilers. Emissions of the boiler had been measured not only under normal combustion conditions, but also under 'idle' combustion conditions when the boiler was not in but was ready for full operation. The experimental results are analysed and presented in this paper. Copyright The Author 2010. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org, Oxford University Press.
International Journa... arrow_drop_down International Journal of Low-Carbon TechnologiesArticle . 2010 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1093/ijlct/ctq006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 14 citations 14 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Low-Carbon TechnologiesArticle . 2010 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1093/ijlct/ctq006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Elsevier BV Authors: Maya Papineau;Abstract The adoption rate and stringency of building energy standards in the U.S. have been increasing since the mid-1990s as a result of the Energy Policy Act mandate of 1992 (EPAct). Current evidence on the energy savings that accrue from commercial building energy standards is based on engineering simulations, which do not account for realized behaviour once a standard is actually adopted. This paper uses quasi-experimental variation in commercial building energy standard adoptions to estimate their effect on realized electricity consumption and cost-effectiveness. In states induced by EPAct to adopt an energy standard where all new nonresidential construction was erected under a commercial standard, electricity consumption per service worker is lower by about 12%, and total commercial electricity consumption is lower by 10%. Including early adopters and never-adopters to the analysis leads to a downward bias in the treatment effect. The realized electricity savings in the EPAct states represent three quarters of predicted simulated savings, and electricity saved in 2010 came at a cost of approximately 7.7 cents per kWh.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.eneco.2017.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu11 citations 11 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.eneco.2017.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013 France, ItalyPublisher:Elsevier BV Authors: EVOLA, GIANPIERO; Le Pierrès, N; Boudehenn, F.; Papillon, P.;handle: 20.500.11769/311862
Abstract In this paper, a general mathematical model for the dynamic simulation of a single-effect LiBr/water absorption chiller is presented. The model is based on mass and energy balances applied to the internal components of the machine, and it accounts for the non-steady behaviour due to thermal and mass storage in the components. The validation of the mathematical model is performed through experimental data collected on a commercial small-capacity water-cooled unit. Due to the peculiar technology adopted in the real chiller, a special effort was made to identify the appropriate values of the main physical parameters. The validation of the model is based on the values of the water temperature at the outlet of the machine, as no measurement inside the machine was possible; anyway, a consistency analysis applied to the internal parameters is also presented. The agreement between experimental and simulated results is very good, both on a daily and on a seasonal basis.
Hyper Article en Lig... arrow_drop_down IRIS - Università degli Studi di CataniaArticle . 2013Data sources: IRIS - Università degli Studi di CataniaInternational Journal of RefrigerationArticle . 2013 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversité Savoie Mont Blanc: HALArticle . 2013Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijrefrig.2012.10.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu72 citations 72 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Hyper Article en Lig... arrow_drop_down IRIS - Università degli Studi di CataniaArticle . 2013Data sources: IRIS - Università degli Studi di CataniaInternational Journal of RefrigerationArticle . 2013 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversité Savoie Mont Blanc: HALArticle . 2013Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijrefrig.2012.10.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Elsevier BV Authors: Kristen S. Cetin; Youngme Seo; Jasmeet Singh; Jongho Im;Abstract For 118 million residential housing units in the U.S., there is currently a gap between the potential energy savings that can be achieved through the use of existing energy efficiency technologies, and the actual level of energy savings realized, particularly for the 37% of housing units that are considered residential rental properties. Additional quantifiable benefits are needed beyond energy savings to help further motivate residential property owners to invest in energy efficiency upgrades. This research focuses on assessing the adoption of energy efficient upgrades in U.S. residential housing and the impact on rental prices. Ten U.S. cities are chosen for analysis; these cities vary in size across multiple climate zones, and represent a diverse set of housing market conditions. Data was collected for over 159,000 rental property listings, their characteristics, and their energy efficiency measures listed in rental housing postings across each city. Following an extensive data quality control process, over thirty different types energy efficient features were identified. The level of adoption was determined for each city, ranging from 5.3% to 21.6%. Efficient lighting and appliances were among the most common, with many features doubling as energy efficient and other desirable aesthetic or comfort improvements. Then using propensity score matching and conditional mean comparison methods, the relative impact on rent charged in each city was calculated, which ranged from a 6% to 14.1% increase in rent for properties with energy efficient features, demonstrating a positive economic impact of these features, particularly for property owners. This was further subdivided into five types of energy efficiency upgrade and three housing types. Single family homes generally demanded higher premiums with energy efficient features, however there was not a consistent pattern across the types of efficient upgrades. The results of this work demonstrate that investment in energy efficient technologies has quantifiable benefits for rental property owners in the U.S. beyond just energy savings. This methodology and results can also be used in other cities and by property owners, utility companies, or others, ultimately encouraging further investment and positive economic impact in residential energy efficiency and in turn improving energy and resource conservation in the building sector.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.047&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu36 citations 36 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.047&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Elsevier BV Funded by:NSERCNSERCAuthors: Mikhail Sorin; Nicolas Galanis; Oumar Samaké;Abstract A new formulation for the evaporation, flashing, condensation processes taking place in the effects of thermal desalination systems which simulates the operation of both forward and parallel/cross configurations is coupled with an exergo-economic model based on the SPECO method. The thermo-economic model uses accurate properties for the seawater, brine, pure water and vapour and is solved with an equation solver which does not require the development of a specific solution algorithm as in most previous studies. This flexible model is used to analyze the influence of the number of effects N and the temperature difference ΔT e between effects on the technical and economic performance of multi-effect desalination systems with ejector vapour compression. In particular, it is shown that the performance calculated by an earlier black-box approach is not attainable by technically and economically realistic systems. It is also shown that for each feed configuration and a given number of effects there exists an optimum value of ΔT e which minimizes the cost of the produced potable water. This last result forms the basis of a procedure that combines black-box results with the optimum value of ΔT e and can be used to select the appropriate system for any specific application.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.12.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu27 citations 27 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.12.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Siddig Omer; Elamin Mohamed; Rami Zeinelabdein; Rami Zeinelabdein;© 2020 Elsevier Ltd Free cooling of buildings uses the nocturnal outdoor air as a heat sink via a ventilation process. This could be performed by storing the night coolness for use during the daytime as appropriate. Due to the latent heat capacity, phase change material (PCM) could play anessential role in the effective operation of the free cooling systems by shifting the daytime peak load to the night. However, there is a scarceness on the technology application in hot climates. This paper presents results of a parametric investigation into the application of PCMs as thermal energy storage (TES) to provide sustainable cooling to buildings in hot arid climate by making use of the night-time free cooling. The proposed TES medium comprises an arrangement of metallic modules filled with RT28HC PCM. Numerous geometrical configurations and operational parameters have been assessed. A transient CFD simulation has been employed using ANSYS Fluent software. Validation of the numerical results with experimental data has shown a good agreement. The results have demonstrated that the temperature difference between the PCM and the air, at appropriate air flow rate would have a significant impact on the performance of the system. A free cooling system based on the proposed arrangement has the potential to meet around 42% of a typical building cooling load and has the ability to save up to 67% of building cooling energy load in summer season compared to conventional air-conditioning systems in hot arid climates.
Journal of Energy St... arrow_drop_down Journal of Energy StorageArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.est.2020.101972&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 26 citations 26 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Journal of Energy St... arrow_drop_down Journal of Energy StorageArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.est.2020.101972&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV Ahmed, Asam; Ge, Tianshu; Peng, Jinqing; Yan, Wei-Cheng; Tee, Boon Tuan; You, Siming;Decarbonizing the building sector is extremely important to mitigating climate change as the sector contributes 40% of the overall energy consumption and 36% of the total greenhouse gas emissions in the world. Net-zero energy buildings are one of the promising decarbonization attempts due to their potential of decreasing the use of energy and increasing the total share of renewable energy. To achieve a net-zero energy building, it is necessary to decrease the energy demand by applying efficiency enhancement measures and using renewable energy sources. Net-zero energy buildings can be classified into four models (Net-Zero Site Energy buildings, Net-Zero Emissions buildings, Net-Zero Source Energy buildings, and Net-Zero Cost Energy buildings). A variety of technical, financial, and environmental factors should be considered during the decision-making process of net-zero energy building development, justifying the use of multi-criteria decision analysis methods for the design of net-zero energy buildings. This paper also discussed the contributions of renewable energy generation (hydropower, wind energy, solar, heat pumps, and bioenergy) to the development of net-zero energy buildings and reviewed its role in tackling the decarbonization challenge. Cost-benefit analysis and life cycle assessment of building designs were reviewed to shape the priorities of future development. It is important to develop a universal decision instrument for optimum design and operation of net-zero energy buildings.
CORE arrow_drop_down CORE (RIOXX-UK Aggregator)Article . 2022License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111755&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 263 citations 263 popularity Top 1% influence Top 1% impulse Top 0.1% Powered by BIP!
more_vert CORE arrow_drop_down CORE (RIOXX-UK Aggregator)Article . 2022License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111755&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 CanadaPublisher:Elsevier BV Authors: Hassan Z. Al Garni; Hassan Z. Al Garni; David Wright; Anjali Awasthi;Abstract This paper uses research-quality, ground measurements of irradiance and temperature that are accurate to ±2% to estimate the electric energy yield of fixed solar modules for utility-scale solar power plants at 18 sites in Saudi Arabia. The calculation is performed for a range of tilt and azimuth angles and the orientation that gives the optimum annual energy yield is determined. A detailed analysis is presented for Riyadh including the impact of non-optimal tilt and azimuth angles on annual energy yield. It is also found that energy yield in March and October are higher than in April and September, due to milder operating temperatures of the modules. A similar optimization of tilt and azimuth is performed each month separately. Adjusting the orientation each month increases energy yield by 4.01% compared to the annual optimum, but requires considerable labour cost. Further analysis shows that an increase in energy yield of 3.63% can be obtained by adjusting the orientation at five selected times during the year, thus significantly reducing the labour requirement. The optimal orientation and corresponding energy yield for all 18 sites is combined with a site suitability analysis taking into account climate, topography and proximity to roads, transmission lines and protected areas. Six sites are selected as having high suitability and high energy yield: Albaha, Arar, Hail, Riyadh, Tabuk and Taif. For these cities the optimal tilt is only slightly higher than the latitude, however the optimum azimuth is from 20° to 53° west of south due to an asymmetrical daily irradiance profile.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2018.10.048&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 89 citations 89 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2018.10.048&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2005Publisher:Elsevier BV Jenny M. Jones; R.I. Backreedy; Lin Ma; Alan Williams; Mohamed Pourkashanian; L. M. Fletcher;Abstract A CFD modelling study has been undertaken to examine the co-firing of pulverised coal and biomass with particular regard to the burnout of the larger diameter biomass particles. Computations were based on a research combustion facility that replicates an industrial coal-fired power station. Three percent, by mass, of pinewood was blended with a bituminous UK coal, and the effects of the wood particle size and shape on the burnout of the combined wood and coal char were investigated. The effect of varying the devolatilisation and char combustion rate constants for the biomass component in the blend was also investigated. It was concluded that the combustion of small (200 μm) wood particles was rapid but the rate of combustion of larger particles was dependent on their composition, size, and shape.
Proceedings of the C... arrow_drop_down Proceedings of the Combustion InstituteArticle . 2005 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.proci.2004.08.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu131 citations 131 popularity Top 10% influence Top 1% impulse Top 10% Powered by BIP!
more_vert Proceedings of the C... arrow_drop_down Proceedings of the Combustion InstituteArticle . 2005 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.proci.2004.08.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014Publisher:Elsevier BV Authors: Juntao Zhou; Shunqi Pan; Roger Alexander Falconer;The Severn Estuary has the world's second largest tide range and a barrage across the estuary, located just seawards of Cardiff in Wales and Weston in the South West England, has been proposed for over half a century, with the objective of extracting large amounts of tidal energy. A Severn Barrage, as previously proposed by the Severn Tidal Power Group (STPG), would be the largest renewable energy project for tidal power generation in the world, if built as proposed, and would generate approximately 5% of the UK's electricity needs. However, concerns have been raised over the environmental impacts of such a barrage, including potential increase in flood risk, loss of intertidal habitats etc. In addressing the challenges of maximizing the energy output and minimizing the environmental impacts of such a barrage, this research study has focused on using a Continental Shelf model, based on the modified Environmental Fluid Dynamics Code (EFDC) with a barrage operation module (EFDC_B), to investigate both the far and near field hydrodynamic impacts of a barrage for different operating scenarios. Three scenarios have been considered to simulate the Severn Barrage, operating via two-way generation and using different combinations of turbines and sluices. The first scenario consisted of 216 turbines and 166 sluices installed along the barrage; the second consisted of 382 turbines with no sluices; and the third consisted of 764 turbines and no sluices. The specification of the sluice gates and turbines are the same for all scenarios. The model results indicate that the third scenario has the best mitigating effects for the far-field and near-field flood risks caused by a barrage and produces the most similar results of minimum water depth and maximum velocity distributions to those obtained from simulating the natural conditions of the estuary, i.e. the current conditions. The results also show that the flow patterns around the barrage are closest to those for the existing natural conditions with minimal slight changes in the estuary. Thus, the results clearly indicate that the environmental impacts of a Severn Barrage can be minimized if the barrage is operated for two-way generation and under the third scenario. Although it appears that the energy output for the third scenario is less than that obtained for the other two scenarios, if very low head (VLH) turbines are used, then the third scenario could generate more energy as more turbines could be cited along the barrage structure. Therefore, the study shows that a Severn Barrage, operating in two-way generation and with 764 turbines (ideally VLH turbines), would be the best option to meet the needs of maximizing the energy output, but having a minimal impact on environmental changes in the estuary and far-field.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2014.07.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu16 citations 16 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.renene.2014.07.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2010Publisher:Oxford University Press (OUP) Authors: Hao Liu; Guoquan Qiu; Yingjuan Shao; Saffa B. Riffat;doi: 10.1093/ijlct/ctq006
Biomass plays an important role in the world primary energy supplies, currently providing ∼14% of the world's primary energy needs and being the fourth largest contributor following coal, oil and natural gas. Over the past decade, domestic biomass heating has received more governmental and public supports than ever before in many developed countries, such as the UK. Although biomass combustion releases some combustion pollutants, biomass is renewable and produces little net CO 2 emissions to the atmosphere. Owing to the low sulphur and low nitrogen contents of many biomass materials, substituting biomass for fossil fuels, particularly coal, can reduce SO x and NO x emissions. This study investigated flue gas emissions, particularly carbon monoxide and nitrogen oxides, of a domestic biomass boiler under various operating conditions. The biomass boiler used in this study satisfies the current EU regulation (EN 303-05) on emissions of domestic biomass boilers. Emissions of the boiler had been measured not only under normal combustion conditions, but also under 'idle' combustion conditions when the boiler was not in but was ready for full operation. The experimental results are analysed and presented in this paper. Copyright The Author 2010. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org, Oxford University Press.
International Journa... arrow_drop_down International Journal of Low-Carbon TechnologiesArticle . 2010 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1093/ijlct/ctq006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 14 citations 14 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Low-Carbon TechnologiesArticle . 2010 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1093/ijlct/ctq006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Elsevier BV Authors: Maya Papineau;Abstract The adoption rate and stringency of building energy standards in the U.S. have been increasing since the mid-1990s as a result of the Energy Policy Act mandate of 1992 (EPAct). Current evidence on the energy savings that accrue from commercial building energy standards is based on engineering simulations, which do not account for realized behaviour once a standard is actually adopted. This paper uses quasi-experimental variation in commercial building energy standard adoptions to estimate their effect on realized electricity consumption and cost-effectiveness. In states induced by EPAct to adopt an energy standard where all new nonresidential construction was erected under a commercial standard, electricity consumption per service worker is lower by about 12%, and total commercial electricity consumption is lower by 10%. Including early adopters and never-adopters to the analysis leads to a downward bias in the treatment effect. The realized electricity savings in the EPAct states represent three quarters of predicted simulated savings, and electricity saved in 2010 came at a cost of approximately 7.7 cents per kWh.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.eneco.2017.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu11 citations 11 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.eneco.2017.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013 France, ItalyPublisher:Elsevier BV Authors: EVOLA, GIANPIERO; Le Pierrès, N; Boudehenn, F.; Papillon, P.;handle: 20.500.11769/311862
Abstract In this paper, a general mathematical model for the dynamic simulation of a single-effect LiBr/water absorption chiller is presented. The model is based on mass and energy balances applied to the internal components of the machine, and it accounts for the non-steady behaviour due to thermal and mass storage in the components. The validation of the mathematical model is performed through experimental data collected on a commercial small-capacity water-cooled unit. Due to the peculiar technology adopted in the real chiller, a special effort was made to identify the appropriate values of the main physical parameters. The validation of the model is based on the values of the water temperature at the outlet of the machine, as no measurement inside the machine was possible; anyway, a consistency analysis applied to the internal parameters is also presented. The agreement between experimental and simulated results is very good, both on a daily and on a seasonal basis.
Hyper Article en Lig... arrow_drop_down IRIS - Università degli Studi di CataniaArticle . 2013Data sources: IRIS - Università degli Studi di CataniaInternational Journal of RefrigerationArticle . 2013 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversité Savoie Mont Blanc: HALArticle . 2013Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijrefrig.2012.10.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu72 citations 72 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Hyper Article en Lig... arrow_drop_down IRIS - Università degli Studi di CataniaArticle . 2013Data sources: IRIS - Università degli Studi di CataniaInternational Journal of RefrigerationArticle . 2013 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversité Savoie Mont Blanc: HALArticle . 2013Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijrefrig.2012.10.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Elsevier BV Authors: Kristen S. Cetin; Youngme Seo; Jasmeet Singh; Jongho Im;Abstract For 118 million residential housing units in the U.S., there is currently a gap between the potential energy savings that can be achieved through the use of existing energy efficiency technologies, and the actual level of energy savings realized, particularly for the 37% of housing units that are considered residential rental properties. Additional quantifiable benefits are needed beyond energy savings to help further motivate residential property owners to invest in energy efficiency upgrades. This research focuses on assessing the adoption of energy efficient upgrades in U.S. residential housing and the impact on rental prices. Ten U.S. cities are chosen for analysis; these cities vary in size across multiple climate zones, and represent a diverse set of housing market conditions. Data was collected for over 159,000 rental property listings, their characteristics, and their energy efficiency measures listed in rental housing postings across each city. Following an extensive data quality control process, over thirty different types energy efficient features were identified. The level of adoption was determined for each city, ranging from 5.3% to 21.6%. Efficient lighting and appliances were among the most common, with many features doubling as energy efficient and other desirable aesthetic or comfort improvements. Then using propensity score matching and conditional mean comparison methods, the relative impact on rent charged in each city was calculated, which ranged from a 6% to 14.1% increase in rent for properties with energy efficient features, demonstrating a positive economic impact of these features, particularly for property owners. This was further subdivided into five types of energy efficiency upgrade and three housing types. Single family homes generally demanded higher premiums with energy efficient features, however there was not a consistent pattern across the types of efficient upgrades. The results of this work demonstrate that investment in energy efficient technologies has quantifiable benefits for rental property owners in the U.S. beyond just energy savings. This methodology and results can also be used in other cities and by property owners, utility companies, or others, ultimately encouraging further investment and positive economic impact in residential energy efficiency and in turn improving energy and resource conservation in the building sector.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.047&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu36 citations 36 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.047&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Elsevier BV Funded by:NSERCNSERCAuthors: Mikhail Sorin; Nicolas Galanis; Oumar Samaké;Abstract A new formulation for the evaporation, flashing, condensation processes taking place in the effects of thermal desalination systems which simulates the operation of both forward and parallel/cross configurations is coupled with an exergo-economic model based on the SPECO method. The thermo-economic model uses accurate properties for the seawater, brine, pure water and vapour and is solved with an equation solver which does not require the development of a specific solution algorithm as in most previous studies. This flexible model is used to analyze the influence of the number of effects N and the temperature difference ΔT e between effects on the technical and economic performance of multi-effect desalination systems with ejector vapour compression. In particular, it is shown that the performance calculated by an earlier black-box approach is not attainable by technically and economically realistic systems. It is also shown that for each feed configuration and a given number of effects there exists an optimum value of ΔT e which minimizes the cost of the produced potable water. This last result forms the basis of a procedure that combines black-box results with the optimum value of ΔT e and can be used to select the appropriate system for any specific application.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.12.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu27 citations 27 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.12.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu