- home
- Advanced Search
- Energy Research
- Open Access
- Closed Access
- Restricted
- DK
- IT University of Copenhagen
- Energy Research
- Open Access
- Closed Access
- Restricted
- DK
- IT University of Copenhagen
description Publicationkeyboard_double_arrow_right Article , Journal 2021 DenmarkPublisher:Springer Science and Business Media LLC Laura H. Rasmussen; Wenxin Zhang; Per Ambus; Anders Michelsen; Per-Erik Jansson; Barbara Kitzler; Bo Elberling;Understanding N budgets of tundra ecosystems is crucial for projecting future changes in plant community composition, greenhouse gas balances and soil N stocks. Winter warming can lead to higher tundra winter nitrogen (N) mineralization rates, while summer warming may increase both growing season N mineralization and plant N demand. The undulating tundra landscape is inter-connected through water and solute movement on top of and within near-surface soil, but the importance of lateral N fluxes for tundra N budgets is not well known. We studied the size of lateral N fluxes and the fate of lateral N input in the snowmelt period with a shallow thaw layer, and in the late growing season with a deeper thaw layer. We used 15N to trace inorganic lateral N movement in a Low-arctic mesic tundra heath slope in West Greenland and to quantify the fate of N in the receiving area. We found that half of the early-season lateral N input was retained by the receiving ecosystem, whereas half was transported downslope. Plants appear as poor utilizers of early-season N, indicating that higher winter N mineralization may influence plant growth and carbon (C) sequestration less than expected. Still, evergreen plants were better at utilizing early-season N, highlighting how changes in N availability may impact plant community composition. In contrast, later growing season lateral N input was deeper and offered an advantage to deeper-rooted deciduous plants. The measurements suggest that N input driven by future warming at the study site will have no significant impact on the overall N2O emissions. Our work underlines how tundra ecosystem N allocation, C budgets and plant community composition vary in their response to lateral N inputs, which may help us understand future responses in a warmer Arctic. (Less)
Biogeochemistry arrow_drop_down University of Copenhagen: ResearchArticle . 2021Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10533-021-00855-y&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 12 citations 12 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Biogeochemistry arrow_drop_down University of Copenhagen: ResearchArticle . 2021Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10533-021-00855-y&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2019 DenmarkPublisher:Institute of Electrical and Electronics Engineers (IEEE) Subham Sahoo; Sukumar Mishra; Seyed Mahdi Fazeli; Furong Li; Tomislav Dragičević;Dans des scénarios réalistes, la performance dynamique d'un cluster de micro-réseaux est largement affectée par la puissance intermittente des sources d'énergie renouvelables et les changements de charge fréquents. Pour résoudre ce problème, un contrôleur secondaire à double couche basé sur le temps fixe distribué est conçu pour améliorer les performances dynamiques inter-microgrid et intra-microgrid dans un temps de stabilisation fixe. Le contrôleur proposé est indépendant des valeurs de fonctionnement initiales par opposition à la loi de contrôle à temps fini. Chaque agent global dans un micro-réseau fonctionne pour atténuer le décalage de charge entre les autres agents globaux, tandis que chaque agent local dans un micro-réseau fonctionne pour réaliser un partage de courant de charge proportionnel et une régulation de tension moyenne entre eux dans un temps fixe. Cependant, comme l'atténuation de la non-concordance de chargement dans des conditions de charge légère affecte l'efficacité du système en raison de pertes de ligne importantes, le fonctionnement du cluster passe à une approche de minimisation des pertes distribuées, qui fonctionne en utilisant des mesures en ligne des micro-réseaux voisins. Pour caractériser le mode de fonctionnement dans la cyber-couche globale, un seuil de point de chargement critique pour le cluster est ainsi déterminé. La performance du cluster utilisant la stratégie proposée est simulée dans l'environnement MATLAB/SIMULINK pour divers scénarios afin de démontrer sa fiabilité et son efficacité. En escenarios realistas, el rendimiento dinámico de un grupo de microrredes se ve afectado en gran medida por la potencia intermitente de las fuentes de energía renovables y los frecuentes cambios de carga. Para abordar este problema, un controlador secundario de doble capa basado en tiempo fijo distribuido está diseñado para mejorar el rendimiento dinámico entre microrredes y entre microrredes dentro de un tiempo de asentamiento fijo. El controlador propuesto es independiente de los valores operativos iniciales en oposición a la ley de control de tiempo finito. Cada agente global en una microrred opera para mitigar el desajuste de carga entre otros agentes globales, mientras que cada agente local en una microrred opera para lograr un reparto de corriente de carga proporcional y una regulación de voltaje promedio entre ellos en un tiempo fijo. Sin embargo, como la mitigación de la falta de coincidencia de carga durante condiciones de carga ligera afecta la eficiencia del sistema debido a pérdidas de línea significativas, la operación del clúster cambia a un enfoque de minimización de pérdidas distribuidas, que opera utilizando mediciones en línea de las microrredes vecinas. Para caracterizar el modo de operación en la capa cibernética global, se determina así un punto crítico de umbral de carga para el clúster. El rendimiento del clúster que emplea la estrategia propuesta se simula en el entorno MATLAB/SIMULINK para varios escenarios para demostrar su confiabilidad y eficiencia. In realistic scenarios, the dynamic performance of a microgrid cluster is largely affected by the intermittent power of renewable energy sources and frequent load changes. To address this issue, a distributed fixed-time based dual layer secondary controller is designed to improve inter-microgrid and intra-microgrid dynamic performance within a fixed settling time. The proposed controller is independent of initial operating values as opposed to the finite time control law. Each global agent in a microgrid operates to mitigate loading mismatch between other global agents, whereas each local agent in a microgrid operates to achieve proportionate load current sharing and average voltage regulation between them in fixed time. However, as loading mismatch mitigation during light load conditions affects the system efficiency due to significant line losses, the cluster operation switches to a distributed loss minimization approach, which operates using online measurements from the neighboring microgrids. To characterize the mode of operation in the global cyber layer, a critical point of loading threshold for the cluster is thus determined. The performance of the cluster employing the proposed strategy is simulated in MATLAB/SIMULINK environment for various scenarios to demonstrate its reliability and efficiency. في السيناريوهات الواقعية، يتأثر الأداء الديناميكي لمجموعة الشبكات الصغيرة إلى حد كبير بالطاقة المتقطعة لمصادر الطاقة المتجددة والتغيرات المتكررة في الحمل. لمعالجة هذه المشكلة، تم تصميم وحدة تحكم ثانوية ثنائية الطبقة موزعة على أساس الوقت الثابت لتحسين الأداء الديناميكي بين الشبكات الدقيقة وداخلها في غضون وقت استقرار ثابت. وحدة التحكم المقترحة مستقلة عن قيم التشغيل الأولية بدلاً من قانون التحكم في الوقت المحدود. يعمل كل عامل عالمي في شبكة صغرى على التخفيف من عدم تطابق التحميل بين العوامل العالمية الأخرى، في حين يعمل كل عامل محلي في شبكة صغرى على تحقيق مشاركة تيار الحمل المتناسب ومتوسط تنظيم الجهد بينهما في وقت محدد. ومع ذلك، نظرًا لأن تخفيف عدم تطابق التحميل أثناء ظروف الحمل الخفيف يؤثر على كفاءة النظام بسبب الخسائر الكبيرة في الخطوط، تتحول عملية المجموعة إلى نهج تقليل الخسارة الموزعة، والذي يعمل باستخدام القياسات عبر الإنترنت من الشبكات الصغيرة المجاورة. لتوصيف طريقة التشغيل في الطبقة السيبرانية العالمية، يتم تحديد نقطة حرجة لعتبة التحميل للمجموعة. تتم محاكاة أداء المجموعة التي تستخدم الاستراتيجية المقترحة في بيئة ماتلاب/سيمولينك لسيناريوهات مختلفة لإثبات موثوقيتها وكفاءتها.
VBN arrow_drop_down IEEE Transactions on Energy ConversionArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tec.2019.2934905&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 29 citations 29 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert VBN arrow_drop_down IEEE Transactions on Energy ConversionArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tec.2019.2934905&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 DenmarkPublisher:Elsevier BV Authors: Poul Alberg Østergaard; Anders N. Andersen;Abstract District heating (DH) enables the utilisation and distribution of heating from sources unfeasible for stand-alone applications and combined with cogeneration of heat and power (CHP), has been the cornerstone of Denmark’s realisation of a steady national primary energy supply over the last four decades. However, progressively more energy-efficient houses and a steadily improving heat pump (HP) performance for individual dwellings is straining the competitive advantage of the CHP–DH combination as DH grid losses are growing in relative terms due to decreasing heating demands of buildings and relatively high DH supply temperatures. A main driver for the DH water temperature is the requirements for domestic hot water (DHW) production. This article investigates two alternatives for DHW supply: (a) DH based on central HPs combined with a heat exchanger, and (b) a combination of DH based on central HPs and a small booster HP using DH water as low-temperature source for DHW production. The analyses are conducted using the energyPRO simulation model and are conducted with hourly varying factors; heating demands, DH grid losses, HP coefficient of performance (COP) and spot market prices in order to be able to analyse the relative performance of the two options and their performance over the year. Results are also compared to individual boilers and individual HPs. The results indicate that applying booster HPs enables the DH system to operate at substantially lower temperature levels, improving the COP of central DH HPs while simultaneously lowering DH grid losses significantly. Thus, DH performance is increased significantly. Additionally, performance for the DH HP with booster combination is considerably better than individual boiler or HP solutions.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.02.144&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 146 citations 146 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.02.144&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 DenmarkPublisher:Elsevier BV Authors: Pedro Cabrera; Henrik Lund; José A. Carta;This paper presents a new method, based on the Smart Energy Systems concept. The aim is to increase the share of renewable energy penetration on islands. The method is applied to the island of Gran Canaria (Spain), considering the entire energy system of the island. Several smart renewable energy strategies are proposed following a cross-sectoral approach between the electricity, heating/cooling, desalination, transport and gas sectors. The different smart renewable energy strategies were applied in a series of steps, while looking for a transition from the current energy system to a nearly 100% renewable energy system. Based on the results, the study concludes that the suggested method is applicable for increasing renewable integration on islands and can potentially be used in helping energy planners to take decisions about priorities in development of the sector to improve such integration. The results indicate that, for the case of Gran Canaria, a 75.9% renewable energy system could be attained with technologies that can be implemented at present. Furthermore, it is shown that a nearly 100% renewable energy system in Gran Canaria is technically feasible and could be achieved if certain technologies acquire greater maturity. © 2018 Elsevier Ltd 443 421 2,048 5,537 Q1 Q1 SCIE
Energy arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2018Data sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.08.020&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 87 citations 87 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2018Data sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.08.020&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Soroush Oshnoei; Arman Oshnoei; Arman Oshnoei; Ali Mosallanejad; Farhad Haghjoo;Abstract This paper presents a novel load frequency control (LFC) model for an interconnected thermal two-area power system in the presence of wind turbine generation and redox flow battery (RFB). The study model includes frequency and voltage excitation loops with needed interactions between them along with the power system stabilizer. A two-degree of freedom (2DOF)-based controller called 2DOF-Hybrid controller is developed as secondary controller in automatic generation control (AGC) to adjust the power outputs of generator and RFB. Also, the dynamic performance of the proposed controller in the RFB loop is evaluated. The Hybrid controller comprises a fractional-order proportional-integral-derivative (FOPID) controller and a tilt-integral-derivative (TID) controller. In order to obtain accurate and realistic results, the outputs of thermal power plants are restricted by considering the limitations of the governor dead-band and generation rate constraint. Since the controller performance depends on its parameters, these parameters are optimized using a modified sine–cosine algorithm (MSCA). The dynamic performance of the proposed 2DOF-Hybrid controller as secondary controller of the AGC loop is compared with integral-double-derivative (IDD), integral-tilt-derivative, proportion-integral–derivative (PID)-DD, 2DOF-PID, 2DOF-TID, and 2DOF-FOPID ones under different scenarios. In addition, the superiority of the MSCA is compared with benchmark metaheuristic methods including an SCA, a genetic algorithm, a particle swarm optimization, and a differential evolution. The sensitivity analysis is also carried out to show the robustness of the proposed controller versus the changes of the parameters. The simulation studies on two-area and New England 39-bus power systems are carried out to examine the advantage of the presented LFC scheme. A range of power system signals such as frequencies of areas, terminal voltages, and tie-line power flow is demonstrated to compare the controllers. The results disclose that the proposed LFC scheme provides better dynamic performance compared to other ones. Moreover, RFB modeling based on the proposed controller is superior to conventional RFB modeling in reducing the amplitude of the oscillations.
International Journa... arrow_drop_down International Journal of Electrical Power & Energy SystemsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefInternational Journal of Electrical Power & Energy SystemsJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijepes.2021.107033&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 71 citations 71 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Electrical Power & Energy SystemsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefInternational Journal of Electrical Power & Energy SystemsJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijepes.2021.107033&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2009 DenmarkPublisher:Institute of Electrical and Electronics Engineers (IEEE) Authors: Chen, Zhe; Wang, L.; Yeh, T-H.; Lee, W.-J;Due to the recent price spike of the international oil and the concern of global warming, the development and deployment of renewable energy become one of the most important energy policies around the globe. Currently, there are different capacities and hub heights for commercial wind turbine generators (WTGs). To fully capture wind energy, different wind farms (WFs) should select adequate capacity of WTGs to effectively harvest wind energy and maximize their economic benefit. To establish selection criterion, this paper first derives the equations for capacity factor (CF) and pairing performance (PP) of WTGs using Weibull and Rayleigh distribution functions. Five commercial WFs in Taiwan are used as sample systems for comparative analyses. This paper combines Weibull function, cubic mean wind speed, and four existing economic-analysis methods to study different values of capacity and hub height for WTGs that have been installed in Taiwan. Important outcomes affecting wind cost of energy in comparison with economic results using the proposed economic-analysis methods for different WFs are also presented.
Research at ASB arrow_drop_down IEEE Transactions on Power SystemsArticle . 2009 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2009.2016519&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 46 citations 46 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Research at ASB arrow_drop_down IEEE Transactions on Power SystemsArticle . 2009 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2009.2016519&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Authors: Amjad Anvari-Moghaddam; Amjad Anvari-Moghaddam; M.J. Vahid-Pakdel; Behnam Mohammadi-Ivatloo; +2 AuthorsAmjad Anvari-Moghaddam; Amjad Anvari-Moghaddam; M.J. Vahid-Pakdel; Behnam Mohammadi-Ivatloo; Behnam Mohammadi-Ivatloo; Farnaz Sohrabi;Abstract This paper proposes an approach for optimal planning of the power to gas energy storage facilities faced by a strategic investor in an electricity market while considering the network constraints. The proposed approach relies on a bi-level programming model whose upper-level problem determines both investment and bidding decisions to maximize the expected profit of the investor and the lower-level problem corresponds to the electricity market clearing. The bi-level model is transferred into a mathematical program with equilibrium constraints through replacing the lower-level problem by its optimality conditions. The resulting nonlinear mathematical program with equilibrium constraints is linearized by using the duality theory and Karush-Kuhn-Tucker optimality conditions. The mixed-integer linear programming problem is solved using GAMS with CPLEX solver. Results pertaining to an illustrative example and a case study are reported and discussed, which validate the proposed approach.
Sustainable Energy T... arrow_drop_down Sustainable Energy Technologies and AssessmentsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.seta.2021.101238&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert Sustainable Energy T... arrow_drop_down Sustainable Energy Technologies and AssessmentsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.seta.2021.101238&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014 DenmarkPublisher:Springer Science and Business Media LLC Authors: Egel, Richard;pmid: 25208738
Self-replicating molecules, in particular RNA, have long been assumed as key to origins of life on Earth. This notion, however, is not very secure since the reduction of life's complexity to self-replication alone relies on thermodynamically untenable assumptions. Alternative, earlier hypotheses about peptide-dominated colloid self-assembly should be revived. Such macromolecular conglomerates presumably existed in a dynamic equilibrium between confluent growth in sessile films and microspheres detached in turbulent suspension. The first organic syntheses may have been driven by mineral-assisted photoactivation at terrestrial geothermal fields, allowing photo-dependent heterotrophic origins of life. Inherently endowed with rudimentary catalyst activities, mineral-associated organic microstructures can have evolved adaptively toward cooperative 'protolife' communities, in which 'protoplasmic continuity' was maintained throughout a graded series of 'proto-biofilms', 'protoorganisms' and 'protocells' toward modern life. The proneness of organic microspheres to merge back into the bulk of sessile films by spontaneous fusion can have made large populations promiscuous from the beginning, which was important for the speed of collective evolution early on. In this protein-centered scenario, the emergent coevolution of uncoded peptides, metabolic cofactors and oligoribonucleotides was primarily optimized for system-supporting catalytic capabilities arising from nonribosomal peptide synthesis and nonreplicative ribonucleotide polymerization, which in turn incorporated other reactive micromolecular organics as vitamins and cofactors into composite macromolecular colloid films and microspheres. Template-dependent replication and gene-encoded protein synthesis emerged as secondary means for further optimization of overall efficieny later on. Eventually, Darwinian speciation of cell-like lineages commenced after minimal gene sets had been bundled in transmissible genomes from multigenomic protoorganisms.
Origins of Life and ... arrow_drop_down Origins of Life and Evolution of BiospheresArticle . 2014 . Peer-reviewedLicense: Springer Nature TDMData sources: CrossrefUniversity of Copenhagen: ResearchArticle . 2014Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s11084-014-9363-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 12 citations 12 popularity Average influence Average impulse Average Powered by BIP!
more_vert Origins of Life and ... arrow_drop_down Origins of Life and Evolution of BiospheresArticle . 2014 . Peer-reviewedLicense: Springer Nature TDMData sources: CrossrefUniversity of Copenhagen: ResearchArticle . 2014Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s11084-014-9363-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020 DenmarkPublisher:Elsevier BV Bin Zhang; Weihao Hu; Jinghua Li; Di Cao; Rui Huang; Qi Huang; Zhe Chen; Frede Blaabjerg;Abstract With the application of advanced information technology for the integration of electricity and natural gas systems, formulating an excellent energy conversion and management strategy has become an effective method to achieve established goals. Differing from previous works, this paper proposes a peak load shifting model to smooth the net load curve of an integrated electricity and natural gas system by coordinating the operations of the power-to-gas unit and generators. Moreover, the study aims to achieve multi-objective optimization while considering the economy of the system. A dynamic energy conversion and management strategy is proposed, which coordinates both the economic cost target and the peak load shifting target by adjusting an economic coefficient. To illustrate the complex energy conversion process, deep reinforcement learning is used to formulate the dynamic energy conversion and management problem as a discrete Markov decision process, and a deep deterministic policy gradient is adopted to solve the decision-making problem. By using the deep reinforcement learning method, the system operator can adaptively determine the conversion ratio of wind power, power-to-gas and gas turbine operations, and generator output through an online process, where the flexibility of wind power generation, wholesale gas price, and the uncertainties of energy demand are considered. Simulation results show that the proposed algorithm can increase the profit of the system operator, reduce wind power curtailment, and smooth the net load curves effectively in real time.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2020.113063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 83 citations 83 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2020.113063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 DenmarkPublisher:Springer Science and Business Media LLC Olivier Dumont; Carolina Carmo; Emelines Georges; Sylvain Quoilin; Vincent Lemort;Net zero energy buildings and positive energy buildings are gaining more and more interest. This paper evaluates the impact of the integration of a battery in a positive energy building used to increase its self-consumption of electricity. Parametric studies are carried out by varying the building envelope characteristics, the power supply system, the climate, the lighting and appliances profiles, the roof tilt angle, the battery size and the electricity tariffs, leading to 3200 cases. The analysis is performed on an annual basis in terms of self-consumption and self-production rate and payback period. It is shown that the battery size leading to the minimum payback period within the input range is comprised between 2.6 and 4.5 kWh. The lowest payback periods, (~7 years), are reached with a well-insulated building envelope, a high lightning and appliance consumption, a low feed-in tariff and a 3.7 kWh battery. Finally, simple correlations (based on the feed-in tariff, the annual electrical consumption and production) to predict the optimal size of battery and the lowest payback period are proposed.
International Journa... arrow_drop_down International Journal of Energy and Environmental EngineeringArticle . 2016 . Peer-reviewedLicense: CC BYData sources: CrossrefInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: UnpayWallInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: COREInternational Journal of Energy and Environmental EngineeringJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s40095-016-0224-2&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 11 citations 11 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Energy and Environmental EngineeringArticle . 2016 . Peer-reviewedLicense: CC BYData sources: CrossrefInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: UnpayWallInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: COREInternational Journal of Energy and Environmental EngineeringJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s40095-016-0224-2&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2021 DenmarkPublisher:Springer Science and Business Media LLC Laura H. Rasmussen; Wenxin Zhang; Per Ambus; Anders Michelsen; Per-Erik Jansson; Barbara Kitzler; Bo Elberling;Understanding N budgets of tundra ecosystems is crucial for projecting future changes in plant community composition, greenhouse gas balances and soil N stocks. Winter warming can lead to higher tundra winter nitrogen (N) mineralization rates, while summer warming may increase both growing season N mineralization and plant N demand. The undulating tundra landscape is inter-connected through water and solute movement on top of and within near-surface soil, but the importance of lateral N fluxes for tundra N budgets is not well known. We studied the size of lateral N fluxes and the fate of lateral N input in the snowmelt period with a shallow thaw layer, and in the late growing season with a deeper thaw layer. We used 15N to trace inorganic lateral N movement in a Low-arctic mesic tundra heath slope in West Greenland and to quantify the fate of N in the receiving area. We found that half of the early-season lateral N input was retained by the receiving ecosystem, whereas half was transported downslope. Plants appear as poor utilizers of early-season N, indicating that higher winter N mineralization may influence plant growth and carbon (C) sequestration less than expected. Still, evergreen plants were better at utilizing early-season N, highlighting how changes in N availability may impact plant community composition. In contrast, later growing season lateral N input was deeper and offered an advantage to deeper-rooted deciduous plants. The measurements suggest that N input driven by future warming at the study site will have no significant impact on the overall N2O emissions. Our work underlines how tundra ecosystem N allocation, C budgets and plant community composition vary in their response to lateral N inputs, which may help us understand future responses in a warmer Arctic. (Less)
Biogeochemistry arrow_drop_down University of Copenhagen: ResearchArticle . 2021Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10533-021-00855-y&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 12 citations 12 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Biogeochemistry arrow_drop_down University of Copenhagen: ResearchArticle . 2021Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10533-021-00855-y&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2019 DenmarkPublisher:Institute of Electrical and Electronics Engineers (IEEE) Subham Sahoo; Sukumar Mishra; Seyed Mahdi Fazeli; Furong Li; Tomislav Dragičević;Dans des scénarios réalistes, la performance dynamique d'un cluster de micro-réseaux est largement affectée par la puissance intermittente des sources d'énergie renouvelables et les changements de charge fréquents. Pour résoudre ce problème, un contrôleur secondaire à double couche basé sur le temps fixe distribué est conçu pour améliorer les performances dynamiques inter-microgrid et intra-microgrid dans un temps de stabilisation fixe. Le contrôleur proposé est indépendant des valeurs de fonctionnement initiales par opposition à la loi de contrôle à temps fini. Chaque agent global dans un micro-réseau fonctionne pour atténuer le décalage de charge entre les autres agents globaux, tandis que chaque agent local dans un micro-réseau fonctionne pour réaliser un partage de courant de charge proportionnel et une régulation de tension moyenne entre eux dans un temps fixe. Cependant, comme l'atténuation de la non-concordance de chargement dans des conditions de charge légère affecte l'efficacité du système en raison de pertes de ligne importantes, le fonctionnement du cluster passe à une approche de minimisation des pertes distribuées, qui fonctionne en utilisant des mesures en ligne des micro-réseaux voisins. Pour caractériser le mode de fonctionnement dans la cyber-couche globale, un seuil de point de chargement critique pour le cluster est ainsi déterminé. La performance du cluster utilisant la stratégie proposée est simulée dans l'environnement MATLAB/SIMULINK pour divers scénarios afin de démontrer sa fiabilité et son efficacité. En escenarios realistas, el rendimiento dinámico de un grupo de microrredes se ve afectado en gran medida por la potencia intermitente de las fuentes de energía renovables y los frecuentes cambios de carga. Para abordar este problema, un controlador secundario de doble capa basado en tiempo fijo distribuido está diseñado para mejorar el rendimiento dinámico entre microrredes y entre microrredes dentro de un tiempo de asentamiento fijo. El controlador propuesto es independiente de los valores operativos iniciales en oposición a la ley de control de tiempo finito. Cada agente global en una microrred opera para mitigar el desajuste de carga entre otros agentes globales, mientras que cada agente local en una microrred opera para lograr un reparto de corriente de carga proporcional y una regulación de voltaje promedio entre ellos en un tiempo fijo. Sin embargo, como la mitigación de la falta de coincidencia de carga durante condiciones de carga ligera afecta la eficiencia del sistema debido a pérdidas de línea significativas, la operación del clúster cambia a un enfoque de minimización de pérdidas distribuidas, que opera utilizando mediciones en línea de las microrredes vecinas. Para caracterizar el modo de operación en la capa cibernética global, se determina así un punto crítico de umbral de carga para el clúster. El rendimiento del clúster que emplea la estrategia propuesta se simula en el entorno MATLAB/SIMULINK para varios escenarios para demostrar su confiabilidad y eficiencia. In realistic scenarios, the dynamic performance of a microgrid cluster is largely affected by the intermittent power of renewable energy sources and frequent load changes. To address this issue, a distributed fixed-time based dual layer secondary controller is designed to improve inter-microgrid and intra-microgrid dynamic performance within a fixed settling time. The proposed controller is independent of initial operating values as opposed to the finite time control law. Each global agent in a microgrid operates to mitigate loading mismatch between other global agents, whereas each local agent in a microgrid operates to achieve proportionate load current sharing and average voltage regulation between them in fixed time. However, as loading mismatch mitigation during light load conditions affects the system efficiency due to significant line losses, the cluster operation switches to a distributed loss minimization approach, which operates using online measurements from the neighboring microgrids. To characterize the mode of operation in the global cyber layer, a critical point of loading threshold for the cluster is thus determined. The performance of the cluster employing the proposed strategy is simulated in MATLAB/SIMULINK environment for various scenarios to demonstrate its reliability and efficiency. في السيناريوهات الواقعية، يتأثر الأداء الديناميكي لمجموعة الشبكات الصغيرة إلى حد كبير بالطاقة المتقطعة لمصادر الطاقة المتجددة والتغيرات المتكررة في الحمل. لمعالجة هذه المشكلة، تم تصميم وحدة تحكم ثانوية ثنائية الطبقة موزعة على أساس الوقت الثابت لتحسين الأداء الديناميكي بين الشبكات الدقيقة وداخلها في غضون وقت استقرار ثابت. وحدة التحكم المقترحة مستقلة عن قيم التشغيل الأولية بدلاً من قانون التحكم في الوقت المحدود. يعمل كل عامل عالمي في شبكة صغرى على التخفيف من عدم تطابق التحميل بين العوامل العالمية الأخرى، في حين يعمل كل عامل محلي في شبكة صغرى على تحقيق مشاركة تيار الحمل المتناسب ومتوسط تنظيم الجهد بينهما في وقت محدد. ومع ذلك، نظرًا لأن تخفيف عدم تطابق التحميل أثناء ظروف الحمل الخفيف يؤثر على كفاءة النظام بسبب الخسائر الكبيرة في الخطوط، تتحول عملية المجموعة إلى نهج تقليل الخسارة الموزعة، والذي يعمل باستخدام القياسات عبر الإنترنت من الشبكات الصغيرة المجاورة. لتوصيف طريقة التشغيل في الطبقة السيبرانية العالمية، يتم تحديد نقطة حرجة لعتبة التحميل للمجموعة. تتم محاكاة أداء المجموعة التي تستخدم الاستراتيجية المقترحة في بيئة ماتلاب/سيمولينك لسيناريوهات مختلفة لإثبات موثوقيتها وكفاءتها.
VBN arrow_drop_down IEEE Transactions on Energy ConversionArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tec.2019.2934905&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 29 citations 29 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert VBN arrow_drop_down IEEE Transactions on Energy ConversionArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tec.2019.2934905&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 DenmarkPublisher:Elsevier BV Authors: Poul Alberg Østergaard; Anders N. Andersen;Abstract District heating (DH) enables the utilisation and distribution of heating from sources unfeasible for stand-alone applications and combined with cogeneration of heat and power (CHP), has been the cornerstone of Denmark’s realisation of a steady national primary energy supply over the last four decades. However, progressively more energy-efficient houses and a steadily improving heat pump (HP) performance for individual dwellings is straining the competitive advantage of the CHP–DH combination as DH grid losses are growing in relative terms due to decreasing heating demands of buildings and relatively high DH supply temperatures. A main driver for the DH water temperature is the requirements for domestic hot water (DHW) production. This article investigates two alternatives for DHW supply: (a) DH based on central HPs combined with a heat exchanger, and (b) a combination of DH based on central HPs and a small booster HP using DH water as low-temperature source for DHW production. The analyses are conducted using the energyPRO simulation model and are conducted with hourly varying factors; heating demands, DH grid losses, HP coefficient of performance (COP) and spot market prices in order to be able to analyse the relative performance of the two options and their performance over the year. Results are also compared to individual boilers and individual HPs. The results indicate that applying booster HPs enables the DH system to operate at substantially lower temperature levels, improving the COP of central DH HPs while simultaneously lowering DH grid losses significantly. Thus, DH performance is increased significantly. Additionally, performance for the DH HP with booster combination is considerably better than individual boiler or HP solutions.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.02.144&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 146 citations 146 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.02.144&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 DenmarkPublisher:Elsevier BV Authors: Pedro Cabrera; Henrik Lund; José A. Carta;This paper presents a new method, based on the Smart Energy Systems concept. The aim is to increase the share of renewable energy penetration on islands. The method is applied to the island of Gran Canaria (Spain), considering the entire energy system of the island. Several smart renewable energy strategies are proposed following a cross-sectoral approach between the electricity, heating/cooling, desalination, transport and gas sectors. The different smart renewable energy strategies were applied in a series of steps, while looking for a transition from the current energy system to a nearly 100% renewable energy system. Based on the results, the study concludes that the suggested method is applicable for increasing renewable integration on islands and can potentially be used in helping energy planners to take decisions about priorities in development of the sector to improve such integration. The results indicate that, for the case of Gran Canaria, a 75.9% renewable energy system could be attained with technologies that can be implemented at present. Furthermore, it is shown that a nearly 100% renewable energy system in Gran Canaria is technically feasible and could be achieved if certain technologies acquire greater maturity. © 2018 Elsevier Ltd 443 421 2,048 5,537 Q1 Q1 SCIE
Energy arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2018Data sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.08.020&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 87 citations 87 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2018Data sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.08.020&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Soroush Oshnoei; Arman Oshnoei; Arman Oshnoei; Ali Mosallanejad; Farhad Haghjoo;Abstract This paper presents a novel load frequency control (LFC) model for an interconnected thermal two-area power system in the presence of wind turbine generation and redox flow battery (RFB). The study model includes frequency and voltage excitation loops with needed interactions between them along with the power system stabilizer. A two-degree of freedom (2DOF)-based controller called 2DOF-Hybrid controller is developed as secondary controller in automatic generation control (AGC) to adjust the power outputs of generator and RFB. Also, the dynamic performance of the proposed controller in the RFB loop is evaluated. The Hybrid controller comprises a fractional-order proportional-integral-derivative (FOPID) controller and a tilt-integral-derivative (TID) controller. In order to obtain accurate and realistic results, the outputs of thermal power plants are restricted by considering the limitations of the governor dead-band and generation rate constraint. Since the controller performance depends on its parameters, these parameters are optimized using a modified sine–cosine algorithm (MSCA). The dynamic performance of the proposed 2DOF-Hybrid controller as secondary controller of the AGC loop is compared with integral-double-derivative (IDD), integral-tilt-derivative, proportion-integral–derivative (PID)-DD, 2DOF-PID, 2DOF-TID, and 2DOF-FOPID ones under different scenarios. In addition, the superiority of the MSCA is compared with benchmark metaheuristic methods including an SCA, a genetic algorithm, a particle swarm optimization, and a differential evolution. The sensitivity analysis is also carried out to show the robustness of the proposed controller versus the changes of the parameters. The simulation studies on two-area and New England 39-bus power systems are carried out to examine the advantage of the presented LFC scheme. A range of power system signals such as frequencies of areas, terminal voltages, and tie-line power flow is demonstrated to compare the controllers. The results disclose that the proposed LFC scheme provides better dynamic performance compared to other ones. Moreover, RFB modeling based on the proposed controller is superior to conventional RFB modeling in reducing the amplitude of the oscillations.
International Journa... arrow_drop_down International Journal of Electrical Power & Energy SystemsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefInternational Journal of Electrical Power & Energy SystemsJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijepes.2021.107033&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 71 citations 71 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Electrical Power & Energy SystemsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefInternational Journal of Electrical Power & Energy SystemsJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijepes.2021.107033&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2009 DenmarkPublisher:Institute of Electrical and Electronics Engineers (IEEE) Authors: Chen, Zhe; Wang, L.; Yeh, T-H.; Lee, W.-J;Due to the recent price spike of the international oil and the concern of global warming, the development and deployment of renewable energy become one of the most important energy policies around the globe. Currently, there are different capacities and hub heights for commercial wind turbine generators (WTGs). To fully capture wind energy, different wind farms (WFs) should select adequate capacity of WTGs to effectively harvest wind energy and maximize their economic benefit. To establish selection criterion, this paper first derives the equations for capacity factor (CF) and pairing performance (PP) of WTGs using Weibull and Rayleigh distribution functions. Five commercial WFs in Taiwan are used as sample systems for comparative analyses. This paper combines Weibull function, cubic mean wind speed, and four existing economic-analysis methods to study different values of capacity and hub height for WTGs that have been installed in Taiwan. Important outcomes affecting wind cost of energy in comparison with economic results using the proposed economic-analysis methods for different WFs are also presented.
Research at ASB arrow_drop_down IEEE Transactions on Power SystemsArticle . 2009 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2009.2016519&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 46 citations 46 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Research at ASB arrow_drop_down IEEE Transactions on Power SystemsArticle . 2009 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2009.2016519&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Authors: Amjad Anvari-Moghaddam; Amjad Anvari-Moghaddam; M.J. Vahid-Pakdel; Behnam Mohammadi-Ivatloo; +2 AuthorsAmjad Anvari-Moghaddam; Amjad Anvari-Moghaddam; M.J. Vahid-Pakdel; Behnam Mohammadi-Ivatloo; Behnam Mohammadi-Ivatloo; Farnaz Sohrabi;Abstract This paper proposes an approach for optimal planning of the power to gas energy storage facilities faced by a strategic investor in an electricity market while considering the network constraints. The proposed approach relies on a bi-level programming model whose upper-level problem determines both investment and bidding decisions to maximize the expected profit of the investor and the lower-level problem corresponds to the electricity market clearing. The bi-level model is transferred into a mathematical program with equilibrium constraints through replacing the lower-level problem by its optimality conditions. The resulting nonlinear mathematical program with equilibrium constraints is linearized by using the duality theory and Karush-Kuhn-Tucker optimality conditions. The mixed-integer linear programming problem is solved using GAMS with CPLEX solver. Results pertaining to an illustrative example and a case study are reported and discussed, which validate the proposed approach.
Sustainable Energy T... arrow_drop_down Sustainable Energy Technologies and AssessmentsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.seta.2021.101238&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert Sustainable Energy T... arrow_drop_down Sustainable Energy Technologies and AssessmentsArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.seta.2021.101238&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014 DenmarkPublisher:Springer Science and Business Media LLC Authors: Egel, Richard;pmid: 25208738
Self-replicating molecules, in particular RNA, have long been assumed as key to origins of life on Earth. This notion, however, is not very secure since the reduction of life's complexity to self-replication alone relies on thermodynamically untenable assumptions. Alternative, earlier hypotheses about peptide-dominated colloid self-assembly should be revived. Such macromolecular conglomerates presumably existed in a dynamic equilibrium between confluent growth in sessile films and microspheres detached in turbulent suspension. The first organic syntheses may have been driven by mineral-assisted photoactivation at terrestrial geothermal fields, allowing photo-dependent heterotrophic origins of life. Inherently endowed with rudimentary catalyst activities, mineral-associated organic microstructures can have evolved adaptively toward cooperative 'protolife' communities, in which 'protoplasmic continuity' was maintained throughout a graded series of 'proto-biofilms', 'protoorganisms' and 'protocells' toward modern life. The proneness of organic microspheres to merge back into the bulk of sessile films by spontaneous fusion can have made large populations promiscuous from the beginning, which was important for the speed of collective evolution early on. In this protein-centered scenario, the emergent coevolution of uncoded peptides, metabolic cofactors and oligoribonucleotides was primarily optimized for system-supporting catalytic capabilities arising from nonribosomal peptide synthesis and nonreplicative ribonucleotide polymerization, which in turn incorporated other reactive micromolecular organics as vitamins and cofactors into composite macromolecular colloid films and microspheres. Template-dependent replication and gene-encoded protein synthesis emerged as secondary means for further optimization of overall efficieny later on. Eventually, Darwinian speciation of cell-like lineages commenced after minimal gene sets had been bundled in transmissible genomes from multigenomic protoorganisms.
Origins of Life and ... arrow_drop_down Origins of Life and Evolution of BiospheresArticle . 2014 . Peer-reviewedLicense: Springer Nature TDMData sources: CrossrefUniversity of Copenhagen: ResearchArticle . 2014Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s11084-014-9363-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 12 citations 12 popularity Average influence Average impulse Average Powered by BIP!
more_vert Origins of Life and ... arrow_drop_down Origins of Life and Evolution of BiospheresArticle . 2014 . Peer-reviewedLicense: Springer Nature TDMData sources: CrossrefUniversity of Copenhagen: ResearchArticle . 2014Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s11084-014-9363-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020 DenmarkPublisher:Elsevier BV Bin Zhang; Weihao Hu; Jinghua Li; Di Cao; Rui Huang; Qi Huang; Zhe Chen; Frede Blaabjerg;Abstract With the application of advanced information technology for the integration of electricity and natural gas systems, formulating an excellent energy conversion and management strategy has become an effective method to achieve established goals. Differing from previous works, this paper proposes a peak load shifting model to smooth the net load curve of an integrated electricity and natural gas system by coordinating the operations of the power-to-gas unit and generators. Moreover, the study aims to achieve multi-objective optimization while considering the economy of the system. A dynamic energy conversion and management strategy is proposed, which coordinates both the economic cost target and the peak load shifting target by adjusting an economic coefficient. To illustrate the complex energy conversion process, deep reinforcement learning is used to formulate the dynamic energy conversion and management problem as a discrete Markov decision process, and a deep deterministic policy gradient is adopted to solve the decision-making problem. By using the deep reinforcement learning method, the system operator can adaptively determine the conversion ratio of wind power, power-to-gas and gas turbine operations, and generator output through an online process, where the flexibility of wind power generation, wholesale gas price, and the uncertainties of energy demand are considered. Simulation results show that the proposed algorithm can increase the profit of the system operator, reduce wind power curtailment, and smooth the net load curves effectively in real time.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2020.113063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 83 citations 83 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2020.113063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 DenmarkPublisher:Springer Science and Business Media LLC Olivier Dumont; Carolina Carmo; Emelines Georges; Sylvain Quoilin; Vincent Lemort;Net zero energy buildings and positive energy buildings are gaining more and more interest. This paper evaluates the impact of the integration of a battery in a positive energy building used to increase its self-consumption of electricity. Parametric studies are carried out by varying the building envelope characteristics, the power supply system, the climate, the lighting and appliances profiles, the roof tilt angle, the battery size and the electricity tariffs, leading to 3200 cases. The analysis is performed on an annual basis in terms of self-consumption and self-production rate and payback period. It is shown that the battery size leading to the minimum payback period within the input range is comprised between 2.6 and 4.5 kWh. The lowest payback periods, (~7 years), are reached with a well-insulated building envelope, a high lightning and appliance consumption, a low feed-in tariff and a 3.7 kWh battery. Finally, simple correlations (based on the feed-in tariff, the annual electrical consumption and production) to predict the optimal size of battery and the lowest payback period are proposed.
International Journa... arrow_drop_down International Journal of Energy and Environmental EngineeringArticle . 2016 . Peer-reviewedLicense: CC BYData sources: CrossrefInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: UnpayWallInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: COREInternational Journal of Energy and Environmental EngineeringJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s40095-016-0224-2&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 11 citations 11 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Energy and Environmental EngineeringArticle . 2016 . Peer-reviewedLicense: CC BYData sources: CrossrefInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: UnpayWallInternational Journal of Energy and Environmental EngineeringArticleLicense: CC BYData sources: COREInternational Journal of Energy and Environmental EngineeringJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s40095-016-0224-2&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu