- home
- Advanced Search
- Energy Research
- Restricted
- Embargo
- other engineering and technologies
- IT
- ES
- PK
- Energy Research
- Restricted
- Embargo
- other engineering and technologies
- IT
- ES
- PK
description Publicationkeyboard_double_arrow_right Article , Journal 2016 ItalyPublisher:Elsevier BV Authors: Costa, G.; POLETTINI, Alessandra; POMI, Raffaella; STRAMAZZO, ALESSIO;In the present work the influence of accelerated mineral carbonation on the leaching behaviour of basic oxygen furnace steel slag was investigated. The environmental behaviour of the material as evaluated through the release of major elements and toxic metals under varying pH conditions was the main focus of the study. Geochemical modelling of the eluates was used to derive a theoretical description of the underlying leaching phenomena for the carbonated material as compared to the original slag. Among the investigated elements, Ca and Si were most appreciably affected by carbonation. A very clear effect of carbonation on leaching was observed for silicate phases, and lower-Ca/Si-ratio minerals were found to control leaching in carbonated slag eluates as compared to the corresponding untreated slag sample as a result of Ca depletion from the residual slag particles. Clear evidence was also gained of solubility control for Ca, Mg and Mn by a number of carbonate minerals, indicating a significant involvement of the original slag constituents in the carbonation process. The release of toxic metals (Zn, V, Cr, Mo) was found to be variously affected by carbonation, owing to different mechanisms including pH changes, dissolution/precipitation of carbonates as well as sorption onto reactive mineral surfaces. The leaching test results were used to derive further considerations on the expected metal release levels on the basis of specific assumptions on the relevant pH domains for the untreated and carbonated slag.
Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu40 citations 40 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 ItalyPublisher:Elsevier BV Authors: Costa, G.; POLETTINI, Alessandra; POMI, Raffaella; STRAMAZZO, ALESSIO;In the present work the influence of accelerated mineral carbonation on the leaching behaviour of basic oxygen furnace steel slag was investigated. The environmental behaviour of the material as evaluated through the release of major elements and toxic metals under varying pH conditions was the main focus of the study. Geochemical modelling of the eluates was used to derive a theoretical description of the underlying leaching phenomena for the carbonated material as compared to the original slag. Among the investigated elements, Ca and Si were most appreciably affected by carbonation. A very clear effect of carbonation on leaching was observed for silicate phases, and lower-Ca/Si-ratio minerals were found to control leaching in carbonated slag eluates as compared to the corresponding untreated slag sample as a result of Ca depletion from the residual slag particles. Clear evidence was also gained of solubility control for Ca, Mg and Mn by a number of carbonate minerals, indicating a significant involvement of the original slag constituents in the carbonation process. The release of toxic metals (Zn, V, Cr, Mo) was found to be variously affected by carbonation, owing to different mechanisms including pH changes, dissolution/precipitation of carbonates as well as sorption onto reactive mineral surfaces. The leaching test results were used to derive further considerations on the expected metal release levels on the basis of specific assumptions on the relevant pH domains for the untreated and carbonated slag.
Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu40 citations 40 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2007 ItalyPublisher:Elsevier BV Authors: VACCARO A; VILLACCI D;handle: 11588/871069
The safeguard of power equipments is assuming a major role in the deregulated electricity market, where a malfunctioning power system could be responsible for serious damages to a large number of system operators having access to the shared energy resource. In this context thermal monitoring of power cables represents a key issue in evaluating the risks associated with a given load management policy especially during emergency conditions. In particular this demands for reliable assessment models that should be able to predict the transient thermal behaviour when the load exceeds the nameplate value. In this connection the application of both simplified and detailed power cable thermal models is often complicated by the presence of uncertainties affecting the tolerances of the input data. The effect of these uncertainties could influence the final solution to a considerable extent. A comprehensive tolerance analysis is therefore required in order to incorporate the effect of data uncertainties into the thermal modelling process. To address this problem, in the paper the employment of interval mathematic is proposed. Several numerical results are presented and discussed in order to assess the effectiveness of the proposed methodology which offer a rough qualitative insight of the solution in a very short time, comparable to the time required for a deterministic numerical simulation.
Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2007 ItalyPublisher:Elsevier BV Authors: VACCARO A; VILLACCI D;handle: 11588/871069
The safeguard of power equipments is assuming a major role in the deregulated electricity market, where a malfunctioning power system could be responsible for serious damages to a large number of system operators having access to the shared energy resource. In this context thermal monitoring of power cables represents a key issue in evaluating the risks associated with a given load management policy especially during emergency conditions. In particular this demands for reliable assessment models that should be able to predict the transient thermal behaviour when the load exceeds the nameplate value. In this connection the application of both simplified and detailed power cable thermal models is often complicated by the presence of uncertainties affecting the tolerances of the input data. The effect of these uncertainties could influence the final solution to a considerable extent. A comprehensive tolerance analysis is therefore required in order to incorporate the effect of data uncertainties into the thermal modelling process. To address this problem, in the paper the employment of interval mathematic is proposed. Several numerical results are presented and discussed in order to assess the effectiveness of the proposed methodology which offer a rough qualitative insight of the solution in a very short time, comparable to the time required for a deterministic numerical simulation.
Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2023 SpainPublisher:Elsevier BV Authors: Sarabia Escrivà, Emilio José; Soto Francés, Víctor Manuel; Pinazo Ojer, José Manuel; Acha, Salvador;handle: 10251/211984
[EN] The objective of this article is to compare the behaviour of the most representative domestic hot water systems (DHW) in single-family buildings. The study evaluates the energy consumption, equivalent CO2 emissions and cost for each system over a 15-year life period. This analysis is carried out in four cli- matic zones across Europe to observe the influence of climatic conditions on the results. The four climatic zones are located in the cities of Athens, Madrid, London and Berlin. The analysed systems are: a) natural gas-fired instantaneous water heaters, b) electric storage water heater, c) solar thermal system with gas- fired instantaneous, d) solar thermal system with electric storage water heater, e) air-source heat pump, f) photovoltaic system with electric storage water heater, and g) photovoltaic system with air-source heat pump. This range of technologies covers the most likely solutions to be implemented across domestic buildings in Europe.The heat pump system (HPWH) with PV considering self-consumption shows the lowest environmen- tal impact in all zones, but is not an attractive investment in the coldest zones due to lower natural gas prices. Thermal solar systems have a high purchase and maintenance costs which do not compensate their energy savings. The PV HPWH system has a greater reduction of emissions and a lower cost than HPWH across a 15-year life. The gas boiler system has the lowest cost in a 15-year period in the coldest areas, despite having a greater environmental impact than the heat pump.(c) 2023 Elsevier B.V. All rights reserved.
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 7 citations 7 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
visibility 6visibility views 6 Powered bymore_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2023 SpainPublisher:Elsevier BV Authors: Sarabia Escrivà, Emilio José; Soto Francés, Víctor Manuel; Pinazo Ojer, José Manuel; Acha, Salvador;handle: 10251/211984
[EN] The objective of this article is to compare the behaviour of the most representative domestic hot water systems (DHW) in single-family buildings. The study evaluates the energy consumption, equivalent CO2 emissions and cost for each system over a 15-year life period. This analysis is carried out in four cli- matic zones across Europe to observe the influence of climatic conditions on the results. The four climatic zones are located in the cities of Athens, Madrid, London and Berlin. The analysed systems are: a) natural gas-fired instantaneous water heaters, b) electric storage water heater, c) solar thermal system with gas- fired instantaneous, d) solar thermal system with electric storage water heater, e) air-source heat pump, f) photovoltaic system with electric storage water heater, and g) photovoltaic system with air-source heat pump. This range of technologies covers the most likely solutions to be implemented across domestic buildings in Europe.The heat pump system (HPWH) with PV considering self-consumption shows the lowest environmen- tal impact in all zones, but is not an attractive investment in the coldest zones due to lower natural gas prices. Thermal solar systems have a high purchase and maintenance costs which do not compensate their energy savings. The PV HPWH system has a greater reduction of emissions and a lower cost than HPWH across a 15-year life. The gas boiler system has the lowest cost in a 15-year period in the coldest areas, despite having a greater environmental impact than the heat pump.(c) 2023 Elsevier B.V. All rights reserved.
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 7 citations 7 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
visibility 6visibility views 6 Powered bymore_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013Publisher:Elsevier BV Authors: Luisa F. Cabeza; Albert Castell; Antoni Gil; Eduard Oró;Abstract Thermal energy storage (TES) systems are growing to a relevant role in solar cooling applications. Hence, high energy density is a desirable property of the TES system. Phase change materials (PCM) helps to increase this characteristic. A high temperature pilot plant able to test different types of TES systems and materials was designed and built at the University of Lleida (Spain). This pilot plant is composed mainly of three parts: heating system, cooling system, and different storage tanks. Two identical storage tanks based on the shell-and-tubes heat exchanger, one of them including 196 squared fins in the bundle of the tubes and the other without, were experimentally tested. Hydroquinone was selected as the storage material, having a latent heat of 205 kJ/kg and a phase change temperature between 168 and 173 °C. The aim of this paper is to test experimentally, and compare the average effectiveness of the TES systems analyzed using PCM for solar cooling and refrigeration applications. It was found out that for the same tank configurations (shell-and-tubes) even changing drastically the dimensions of the tank or the number and the diameter of the tubes, the average effectiveness curve proposed in the literature fits well with the results showed here.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu52 citations 52 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013Publisher:Elsevier BV Authors: Luisa F. Cabeza; Albert Castell; Antoni Gil; Eduard Oró;Abstract Thermal energy storage (TES) systems are growing to a relevant role in solar cooling applications. Hence, high energy density is a desirable property of the TES system. Phase change materials (PCM) helps to increase this characteristic. A high temperature pilot plant able to test different types of TES systems and materials was designed and built at the University of Lleida (Spain). This pilot plant is composed mainly of three parts: heating system, cooling system, and different storage tanks. Two identical storage tanks based on the shell-and-tubes heat exchanger, one of them including 196 squared fins in the bundle of the tubes and the other without, were experimentally tested. Hydroquinone was selected as the storage material, having a latent heat of 205 kJ/kg and a phase change temperature between 168 and 173 °C. The aim of this paper is to test experimentally, and compare the average effectiveness of the TES systems analyzed using PCM for solar cooling and refrigeration applications. It was found out that for the same tank configurations (shell-and-tubes) even changing drastically the dimensions of the tank or the number and the diameter of the tubes, the average effectiveness curve proposed in the literature fits well with the results showed here.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu52 citations 52 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2014 SpainPublisher:Wiley Authors: Whittlesey, Michael K.; Peris, Eduardo;AbstractReview: 105 refs.
Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu148 citations 148 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
visibility 22visibility views 22 Powered bymore_vert Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2014 SpainPublisher:Wiley Authors: Whittlesey, Michael K.; Peris, Eduardo;AbstractReview: 105 refs.
Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu148 citations 148 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
visibility 22visibility views 22 Powered bymore_vert Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 SpainPublisher:Elsevier BV Marta Chàfer; Marta Chàfer; Luisa F. Cabeza; Julià Coma; Gabriel Pérez;handle: 10459.1/71694
The building and construction sector is a large contributor to anthropogenic greenhouse gas emissions and consumes vast natural resources. Improvements in this sector are of fundamental importance for national and global targets to combat climate change. In this context, vertical greenery systems (VGS) in buildings have become popular in urban areas to restore green space in cities and be an adaptation strategy for challenges such as climate change. However, only a small amount of knowledge is available on the different VGS environmental impacts. This paper discusses a comparative life cycle assessment (LCA) between a building with green walls, a building with green facades and a reference building without any greenery system in the continental Mediterranean climate. This life cycle assessment is carried according to ISO 14040/44 using ReCiPe and GWP indicators. Moreover, this study fills this gap by thoroughly tracking and quantifying all impacts in all phases of the building life cycle related to the manufacturing and construction stage, maintenance, use stage (operational energy use experimentally tested), and final disposal. The adopted functional unit is the square meter of the facade. Results showed that the operational stage had the highest impact contributing by up to 90% of the total environmental impacts during its 50 years life cycle. Moreover, when considering VGS, there is an annual reduction of about 1% in the environmental burdens. However, in summer, the reduction is almost 50%. Finally, if the use stage is excluded, the manufacturing and the maintenance stage are the most significant contributors, especially in the green wall system.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu32 citations 32 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 SpainPublisher:Elsevier BV Marta Chàfer; Marta Chàfer; Luisa F. Cabeza; Julià Coma; Gabriel Pérez;handle: 10459.1/71694
The building and construction sector is a large contributor to anthropogenic greenhouse gas emissions and consumes vast natural resources. Improvements in this sector are of fundamental importance for national and global targets to combat climate change. In this context, vertical greenery systems (VGS) in buildings have become popular in urban areas to restore green space in cities and be an adaptation strategy for challenges such as climate change. However, only a small amount of knowledge is available on the different VGS environmental impacts. This paper discusses a comparative life cycle assessment (LCA) between a building with green walls, a building with green facades and a reference building without any greenery system in the continental Mediterranean climate. This life cycle assessment is carried according to ISO 14040/44 using ReCiPe and GWP indicators. Moreover, this study fills this gap by thoroughly tracking and quantifying all impacts in all phases of the building life cycle related to the manufacturing and construction stage, maintenance, use stage (operational energy use experimentally tested), and final disposal. The adopted functional unit is the square meter of the facade. Results showed that the operational stage had the highest impact contributing by up to 90% of the total environmental impacts during its 50 years life cycle. Moreover, when considering VGS, there is an annual reduction of about 1% in the environmental burdens. However, in summer, the reduction is almost 50%. Finally, if the use stage is excluded, the manufacturing and the maintenance stage are the most significant contributors, especially in the green wall system.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu32 citations 32 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004 ItalyPublisher:Elsevier BV Authors: S Cattarin; M Musiani;handle: 20.500.14243/53041
The electrodissolution of p-Ge in aqueous NaOH solutions (pH 12-13) has been investigated with steady-state and impedance techniques. In the potential region where the process is under kinetic control, the impedance patterns are characterised by a high frequency capacitive loop, associated with the space charge, largely merged with another due to charge transfer resistance and double layer capacitance, and two low frequency loops changing from inductive to capacitive upon increasing the potential. At larger potential, under mixed control, the same high frequency features are observed, while a convection diffusion impedance dominates the low frequency response. The data relevant to pure kinetic control are interpreted with a simplified kinetic model, based on the classical scheme of Beck and Gerischer [Z. Electrochem., Ber. Bunsenges. Physik. Chem. 63 (1959) 500], neglecting transport effects and assuming only three electrochemical steps: (i) oxidation, involving water molecules, of Ge(0) to dihydroxylated Ge(II) by two holes; (ii) oxidation by one hole of Ge(II)-Ge(III) in a step requiring OH-; (iii) oxidative dissolution of Ge(III) proceeding either by hole capture or electron injection, leaving behind a surface Ge(0) species. Diagrams calculated for the limiting cases of pure depletion layer control reproduce the essential features of the experimental ones.
IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu5 citations 5 popularity Average influence Average impulse Average Powered by BIP!
more_vert IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004 ItalyPublisher:Elsevier BV Authors: S Cattarin; M Musiani;handle: 20.500.14243/53041
The electrodissolution of p-Ge in aqueous NaOH solutions (pH 12-13) has been investigated with steady-state and impedance techniques. In the potential region where the process is under kinetic control, the impedance patterns are characterised by a high frequency capacitive loop, associated with the space charge, largely merged with another due to charge transfer resistance and double layer capacitance, and two low frequency loops changing from inductive to capacitive upon increasing the potential. At larger potential, under mixed control, the same high frequency features are observed, while a convection diffusion impedance dominates the low frequency response. The data relevant to pure kinetic control are interpreted with a simplified kinetic model, based on the classical scheme of Beck and Gerischer [Z. Electrochem., Ber. Bunsenges. Physik. Chem. 63 (1959) 500], neglecting transport effects and assuming only three electrochemical steps: (i) oxidation, involving water molecules, of Ge(0) to dihydroxylated Ge(II) by two holes; (ii) oxidation by one hole of Ge(II)-Ge(III) in a step requiring OH-; (iii) oxidative dissolution of Ge(III) proceeding either by hole capture or electron injection, leaving behind a surface Ge(0) species. Diagrams calculated for the limiting cases of pure depletion layer control reproduce the essential features of the experimental ones.
IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu5 citations 5 popularity Average influence Average impulse Average Powered by BIP!
more_vert IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2012 SpainPublisher:Elsevier BV Authors: Cerisola Lopez De Haro, Santiago; Latorre Canteli, Jesús María; Ramos Galán, Andrés;handle: 11531/5041
Artículos en revistas In this paper we apply stochastic dual dynamic programming decomposition to a nonconvex multistage stochastic hydrothermal model where the nonlinear water head effects on production and the nonlinear dependence between the reservoir head and the reservoir volume are modeled. The nonconvex constraints that represent the production function of a hydro plant are approximated by McCormick envelopes. These constraints are split into smaller regions and the McCormick envelopes are used for each region. We use binary variables for this disjunctive programming approach and solve the problem with a decomposition method. We resort to a variant of the L-shaped method for solving the MIP subproblem with binary variables at any stage inside the stochastic dual dynamic programming algorithm. A realistic large-scale case study is presented. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu78 citations 78 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2012 SpainPublisher:Elsevier BV Authors: Cerisola Lopez De Haro, Santiago; Latorre Canteli, Jesús María; Ramos Galán, Andrés;handle: 11531/5041
Artículos en revistas In this paper we apply stochastic dual dynamic programming decomposition to a nonconvex multistage stochastic hydrothermal model where the nonlinear water head effects on production and the nonlinear dependence between the reservoir head and the reservoir volume are modeled. The nonconvex constraints that represent the production function of a hydro plant are approximated by McCormick envelopes. These constraints are split into smaller regions and the McCormick envelopes are used for each region. We use binary variables for this disjunctive programming approach and solve the problem with a decomposition method. We resort to a variant of the L-shaped method for solving the MIP subproblem with binary variables at any stage inside the stochastic dual dynamic programming algorithm. A realistic large-scale case study is presented. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu78 citations 78 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, Spain, ItalyPublisher:Elsevier BV Authors: Gaspari, Michele; Lorenzoni, Arturo; Frías, Pablo; Reneses, Javier;handle: 11577/3261557 , 11531/17382
Artículos en revistas Liberalization policies, the challenges of integrating distributed generation resources, and the recent flattening of electricity demand due to the economic crisis and technological change have led to lower returns for European electricity suppliers. Innovative and sustainable business models are needed to serve electricity customers while reflecting the operational needs of the system and maintaining supplier financial viability. This paper describes a novel model of Integrated Energy Services that encompasses distributed generation (DG) and demand response (DR) resources for industrial customers. We further reflect on some of the market opportunities and regulatory drivers for the development of similar schemes across Europe. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, Spain, ItalyPublisher:Elsevier BV Authors: Gaspari, Michele; Lorenzoni, Arturo; Frías, Pablo; Reneses, Javier;handle: 11577/3261557 , 11531/17382
Artículos en revistas Liberalization policies, the challenges of integrating distributed generation resources, and the recent flattening of electricity demand due to the economic crisis and technological change have led to lower returns for European electricity suppliers. Innovative and sustainable business models are needed to serve electricity customers while reflecting the operational needs of the system and maintaining supplier financial viability. This paper describes a novel model of Integrated Energy Services that encompasses distributed generation (DG) and demand response (DR) resources for industrial customers. We further reflect on some of the market opportunities and regulatory drivers for the development of similar schemes across Europe. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2016 ItalyPublisher:Elsevier BV Authors: Costa, G.; POLETTINI, Alessandra; POMI, Raffaella; STRAMAZZO, ALESSIO;In the present work the influence of accelerated mineral carbonation on the leaching behaviour of basic oxygen furnace steel slag was investigated. The environmental behaviour of the material as evaluated through the release of major elements and toxic metals under varying pH conditions was the main focus of the study. Geochemical modelling of the eluates was used to derive a theoretical description of the underlying leaching phenomena for the carbonated material as compared to the original slag. Among the investigated elements, Ca and Si were most appreciably affected by carbonation. A very clear effect of carbonation on leaching was observed for silicate phases, and lower-Ca/Si-ratio minerals were found to control leaching in carbonated slag eluates as compared to the corresponding untreated slag sample as a result of Ca depletion from the residual slag particles. Clear evidence was also gained of solubility control for Ca, Mg and Mn by a number of carbonate minerals, indicating a significant involvement of the original slag constituents in the carbonation process. The release of toxic metals (Zn, V, Cr, Mo) was found to be variously affected by carbonation, owing to different mechanisms including pH changes, dissolution/precipitation of carbonates as well as sorption onto reactive mineral surfaces. The leaching test results were used to derive further considerations on the expected metal release levels on the basis of specific assumptions on the relevant pH domains for the untreated and carbonated slag.
Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu40 citations 40 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 ItalyPublisher:Elsevier BV Authors: Costa, G.; POLETTINI, Alessandra; POMI, Raffaella; STRAMAZZO, ALESSIO;In the present work the influence of accelerated mineral carbonation on the leaching behaviour of basic oxygen furnace steel slag was investigated. The environmental behaviour of the material as evaluated through the release of major elements and toxic metals under varying pH conditions was the main focus of the study. Geochemical modelling of the eluates was used to derive a theoretical description of the underlying leaching phenomena for the carbonated material as compared to the original slag. Among the investigated elements, Ca and Si were most appreciably affected by carbonation. A very clear effect of carbonation on leaching was observed for silicate phases, and lower-Ca/Si-ratio minerals were found to control leaching in carbonated slag eluates as compared to the corresponding untreated slag sample as a result of Ca depletion from the residual slag particles. Clear evidence was also gained of solubility control for Ca, Mg and Mn by a number of carbonate minerals, indicating a significant involvement of the original slag constituents in the carbonation process. The release of toxic metals (Zn, V, Cr, Mo) was found to be variously affected by carbonation, owing to different mechanisms including pH changes, dissolution/precipitation of carbonates as well as sorption onto reactive mineral surfaces. The leaching test results were used to derive further considerations on the expected metal release levels on the basis of specific assumptions on the relevant pH domains for the untreated and carbonated slag.
Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu40 citations 40 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Journal of Hazardous MaterialsArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Archivio della Ricerca - Università di Roma Tor vergataArchivio della Ricerca - Università di Roma Tor vergataArticle . 2016Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jhazmat.2015.10.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2007 ItalyPublisher:Elsevier BV Authors: VACCARO A; VILLACCI D;handle: 11588/871069
The safeguard of power equipments is assuming a major role in the deregulated electricity market, where a malfunctioning power system could be responsible for serious damages to a large number of system operators having access to the shared energy resource. In this context thermal monitoring of power cables represents a key issue in evaluating the risks associated with a given load management policy especially during emergency conditions. In particular this demands for reliable assessment models that should be able to predict the transient thermal behaviour when the load exceeds the nameplate value. In this connection the application of both simplified and detailed power cable thermal models is often complicated by the presence of uncertainties affecting the tolerances of the input data. The effect of these uncertainties could influence the final solution to a considerable extent. A comprehensive tolerance analysis is therefore required in order to incorporate the effect of data uncertainties into the thermal modelling process. To address this problem, in the paper the employment of interval mathematic is proposed. Several numerical results are presented and discussed in order to assess the effectiveness of the proposed methodology which offer a rough qualitative insight of the solution in a very short time, comparable to the time required for a deterministic numerical simulation.
Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2007 ItalyPublisher:Elsevier BV Authors: VACCARO A; VILLACCI D;handle: 11588/871069
The safeguard of power equipments is assuming a major role in the deregulated electricity market, where a malfunctioning power system could be responsible for serious damages to a large number of system operators having access to the shared energy resource. In this context thermal monitoring of power cables represents a key issue in evaluating the risks associated with a given load management policy especially during emergency conditions. In particular this demands for reliable assessment models that should be able to predict the transient thermal behaviour when the load exceeds the nameplate value. In this connection the application of both simplified and detailed power cable thermal models is often complicated by the presence of uncertainties affecting the tolerances of the input data. The effect of these uncertainties could influence the final solution to a considerable extent. A comprehensive tolerance analysis is therefore required in order to incorporate the effect of data uncertainties into the thermal modelling process. To address this problem, in the paper the employment of interval mathematic is proposed. Several numerical results are presented and discussed in order to assess the effectiveness of the proposed methodology which offer a rough qualitative insight of the solution in a very short time, comparable to the time required for a deterministic numerical simulation.
Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert Archivio della ricer... arrow_drop_down Electric Power Systems ResearchArticle . 2007 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.epsr.2006.03.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2023 SpainPublisher:Elsevier BV Authors: Sarabia Escrivà, Emilio José; Soto Francés, Víctor Manuel; Pinazo Ojer, José Manuel; Acha, Salvador;handle: 10251/211984
[EN] The objective of this article is to compare the behaviour of the most representative domestic hot water systems (DHW) in single-family buildings. The study evaluates the energy consumption, equivalent CO2 emissions and cost for each system over a 15-year life period. This analysis is carried out in four cli- matic zones across Europe to observe the influence of climatic conditions on the results. The four climatic zones are located in the cities of Athens, Madrid, London and Berlin. The analysed systems are: a) natural gas-fired instantaneous water heaters, b) electric storage water heater, c) solar thermal system with gas- fired instantaneous, d) solar thermal system with electric storage water heater, e) air-source heat pump, f) photovoltaic system with electric storage water heater, and g) photovoltaic system with air-source heat pump. This range of technologies covers the most likely solutions to be implemented across domestic buildings in Europe.The heat pump system (HPWH) with PV considering self-consumption shows the lowest environmen- tal impact in all zones, but is not an attractive investment in the coldest zones due to lower natural gas prices. Thermal solar systems have a high purchase and maintenance costs which do not compensate their energy savings. The PV HPWH system has a greater reduction of emissions and a lower cost than HPWH across a 15-year life. The gas boiler system has the lowest cost in a 15-year period in the coldest areas, despite having a greater environmental impact than the heat pump.(c) 2023 Elsevier B.V. All rights reserved.
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 7 citations 7 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
visibility 6visibility views 6 Powered bymore_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2023 SpainPublisher:Elsevier BV Authors: Sarabia Escrivà, Emilio José; Soto Francés, Víctor Manuel; Pinazo Ojer, José Manuel; Acha, Salvador;handle: 10251/211984
[EN] The objective of this article is to compare the behaviour of the most representative domestic hot water systems (DHW) in single-family buildings. The study evaluates the energy consumption, equivalent CO2 emissions and cost for each system over a 15-year life period. This analysis is carried out in four cli- matic zones across Europe to observe the influence of climatic conditions on the results. The four climatic zones are located in the cities of Athens, Madrid, London and Berlin. The analysed systems are: a) natural gas-fired instantaneous water heaters, b) electric storage water heater, c) solar thermal system with gas- fired instantaneous, d) solar thermal system with electric storage water heater, e) air-source heat pump, f) photovoltaic system with electric storage water heater, and g) photovoltaic system with air-source heat pump. This range of technologies covers the most likely solutions to be implemented across domestic buildings in Europe.The heat pump system (HPWH) with PV considering self-consumption shows the lowest environmen- tal impact in all zones, but is not an attractive investment in the coldest zones due to lower natural gas prices. Thermal solar systems have a high purchase and maintenance costs which do not compensate their energy savings. The PV HPWH system has a greater reduction of emissions and a lower cost than HPWH across a 15-year life. The gas boiler system has the lowest cost in a 15-year period in the coldest areas, despite having a greater environmental impact than the heat pump.(c) 2023 Elsevier B.V. All rights reserved.
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 7 citations 7 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
visibility 6visibility views 6 Powered bymore_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2023License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.112925&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013Publisher:Elsevier BV Authors: Luisa F. Cabeza; Albert Castell; Antoni Gil; Eduard Oró;Abstract Thermal energy storage (TES) systems are growing to a relevant role in solar cooling applications. Hence, high energy density is a desirable property of the TES system. Phase change materials (PCM) helps to increase this characteristic. A high temperature pilot plant able to test different types of TES systems and materials was designed and built at the University of Lleida (Spain). This pilot plant is composed mainly of three parts: heating system, cooling system, and different storage tanks. Two identical storage tanks based on the shell-and-tubes heat exchanger, one of them including 196 squared fins in the bundle of the tubes and the other without, were experimentally tested. Hydroquinone was selected as the storage material, having a latent heat of 205 kJ/kg and a phase change temperature between 168 and 173 °C. The aim of this paper is to test experimentally, and compare the average effectiveness of the TES systems analyzed using PCM for solar cooling and refrigeration applications. It was found out that for the same tank configurations (shell-and-tubes) even changing drastically the dimensions of the tank or the number and the diameter of the tubes, the average effectiveness curve proposed in the literature fits well with the results showed here.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu52 citations 52 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013Publisher:Elsevier BV Authors: Luisa F. Cabeza; Albert Castell; Antoni Gil; Eduard Oró;Abstract Thermal energy storage (TES) systems are growing to a relevant role in solar cooling applications. Hence, high energy density is a desirable property of the TES system. Phase change materials (PCM) helps to increase this characteristic. A high temperature pilot plant able to test different types of TES systems and materials was designed and built at the University of Lleida (Spain). This pilot plant is composed mainly of three parts: heating system, cooling system, and different storage tanks. Two identical storage tanks based on the shell-and-tubes heat exchanger, one of them including 196 squared fins in the bundle of the tubes and the other without, were experimentally tested. Hydroquinone was selected as the storage material, having a latent heat of 205 kJ/kg and a phase change temperature between 168 and 173 °C. The aim of this paper is to test experimentally, and compare the average effectiveness of the TES systems analyzed using PCM for solar cooling and refrigeration applications. It was found out that for the same tank configurations (shell-and-tubes) even changing drastically the dimensions of the tank or the number and the diameter of the tubes, the average effectiveness curve proposed in the literature fits well with the results showed here.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu52 citations 52 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2013.02.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2014 SpainPublisher:Wiley Authors: Whittlesey, Michael K.; Peris, Eduardo;AbstractReview: 105 refs.
Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu148 citations 148 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
visibility 22visibility views 22 Powered bymore_vert Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2014 SpainPublisher:Wiley Authors: Whittlesey, Michael K.; Peris, Eduardo;AbstractReview: 105 refs.
Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu148 citations 148 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
visibility 22visibility views 22 Powered bymore_vert Repositori Instituci... arrow_drop_down Repositori Institucional de la Universitat Jaume IArticle . 2014Data sources: Repositori Institucional de la Universitat Jaume IChemInformArticle . 2014 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/chin.201444261&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 SpainPublisher:Elsevier BV Marta Chàfer; Marta Chàfer; Luisa F. Cabeza; Julià Coma; Gabriel Pérez;handle: 10459.1/71694
The building and construction sector is a large contributor to anthropogenic greenhouse gas emissions and consumes vast natural resources. Improvements in this sector are of fundamental importance for national and global targets to combat climate change. In this context, vertical greenery systems (VGS) in buildings have become popular in urban areas to restore green space in cities and be an adaptation strategy for challenges such as climate change. However, only a small amount of knowledge is available on the different VGS environmental impacts. This paper discusses a comparative life cycle assessment (LCA) between a building with green walls, a building with green facades and a reference building without any greenery system in the continental Mediterranean climate. This life cycle assessment is carried according to ISO 14040/44 using ReCiPe and GWP indicators. Moreover, this study fills this gap by thoroughly tracking and quantifying all impacts in all phases of the building life cycle related to the manufacturing and construction stage, maintenance, use stage (operational energy use experimentally tested), and final disposal. The adopted functional unit is the square meter of the facade. Results showed that the operational stage had the highest impact contributing by up to 90% of the total environmental impacts during its 50 years life cycle. Moreover, when considering VGS, there is an annual reduction of about 1% in the environmental burdens. However, in summer, the reduction is almost 50%. Finally, if the use stage is excluded, the manufacturing and the maintenance stage are the most significant contributors, especially in the green wall system.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu32 citations 32 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 SpainPublisher:Elsevier BV Marta Chàfer; Marta Chàfer; Luisa F. Cabeza; Julià Coma; Gabriel Pérez;handle: 10459.1/71694
The building and construction sector is a large contributor to anthropogenic greenhouse gas emissions and consumes vast natural resources. Improvements in this sector are of fundamental importance for national and global targets to combat climate change. In this context, vertical greenery systems (VGS) in buildings have become popular in urban areas to restore green space in cities and be an adaptation strategy for challenges such as climate change. However, only a small amount of knowledge is available on the different VGS environmental impacts. This paper discusses a comparative life cycle assessment (LCA) between a building with green walls, a building with green facades and a reference building without any greenery system in the continental Mediterranean climate. This life cycle assessment is carried according to ISO 14040/44 using ReCiPe and GWP indicators. Moreover, this study fills this gap by thoroughly tracking and quantifying all impacts in all phases of the building life cycle related to the manufacturing and construction stage, maintenance, use stage (operational energy use experimentally tested), and final disposal. The adopted functional unit is the square meter of the facade. Results showed that the operational stage had the highest impact contributing by up to 90% of the total environmental impacts during its 50 years life cycle. Moreover, when considering VGS, there is an annual reduction of about 1% in the environmental burdens. However, in summer, the reduction is almost 50%. Finally, if the use stage is excluded, the manufacturing and the maintenance stage are the most significant contributors, especially in the green wall system.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu32 citations 32 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2021.111236&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004 ItalyPublisher:Elsevier BV Authors: S Cattarin; M Musiani;handle: 20.500.14243/53041
The electrodissolution of p-Ge in aqueous NaOH solutions (pH 12-13) has been investigated with steady-state and impedance techniques. In the potential region where the process is under kinetic control, the impedance patterns are characterised by a high frequency capacitive loop, associated with the space charge, largely merged with another due to charge transfer resistance and double layer capacitance, and two low frequency loops changing from inductive to capacitive upon increasing the potential. At larger potential, under mixed control, the same high frequency features are observed, while a convection diffusion impedance dominates the low frequency response. The data relevant to pure kinetic control are interpreted with a simplified kinetic model, based on the classical scheme of Beck and Gerischer [Z. Electrochem., Ber. Bunsenges. Physik. Chem. 63 (1959) 500], neglecting transport effects and assuming only three electrochemical steps: (i) oxidation, involving water molecules, of Ge(0) to dihydroxylated Ge(II) by two holes; (ii) oxidation by one hole of Ge(II)-Ge(III) in a step requiring OH-; (iii) oxidative dissolution of Ge(III) proceeding either by hole capture or electron injection, leaving behind a surface Ge(0) species. Diagrams calculated for the limiting cases of pure depletion layer control reproduce the essential features of the experimental ones.
IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu5 citations 5 popularity Average influence Average impulse Average Powered by BIP!
more_vert IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004 ItalyPublisher:Elsevier BV Authors: S Cattarin; M Musiani;handle: 20.500.14243/53041
The electrodissolution of p-Ge in aqueous NaOH solutions (pH 12-13) has been investigated with steady-state and impedance techniques. In the potential region where the process is under kinetic control, the impedance patterns are characterised by a high frequency capacitive loop, associated with the space charge, largely merged with another due to charge transfer resistance and double layer capacitance, and two low frequency loops changing from inductive to capacitive upon increasing the potential. At larger potential, under mixed control, the same high frequency features are observed, while a convection diffusion impedance dominates the low frequency response. The data relevant to pure kinetic control are interpreted with a simplified kinetic model, based on the classical scheme of Beck and Gerischer [Z. Electrochem., Ber. Bunsenges. Physik. Chem. 63 (1959) 500], neglecting transport effects and assuming only three electrochemical steps: (i) oxidation, involving water molecules, of Ge(0) to dihydroxylated Ge(II) by two holes; (ii) oxidation by one hole of Ge(II)-Ge(III) in a step requiring OH-; (iii) oxidative dissolution of Ge(III) proceeding either by hole capture or electron injection, leaving behind a surface Ge(0) species. Diagrams calculated for the limiting cases of pure depletion layer control reproduce the essential features of the experimental ones.
IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu5 citations 5 popularity Average influence Average impulse Average Powered by BIP!
more_vert IRIS Cnr arrow_drop_down Journal of Electroanalytical ChemistryArticle . 2004 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jelechem.2003.11.036&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2012 SpainPublisher:Elsevier BV Authors: Cerisola Lopez De Haro, Santiago; Latorre Canteli, Jesús María; Ramos Galán, Andrés;handle: 11531/5041
Artículos en revistas In this paper we apply stochastic dual dynamic programming decomposition to a nonconvex multistage stochastic hydrothermal model where the nonlinear water head effects on production and the nonlinear dependence between the reservoir head and the reservoir volume are modeled. The nonconvex constraints that represent the production function of a hydro plant are approximated by McCormick envelopes. These constraints are split into smaller regions and the McCormick envelopes are used for each region. We use binary variables for this disjunctive programming approach and solve the problem with a decomposition method. We resort to a variant of the L-shaped method for solving the MIP subproblem with binary variables at any stage inside the stochastic dual dynamic programming algorithm. A realistic large-scale case study is presented. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu78 citations 78 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2012 SpainPublisher:Elsevier BV Authors: Cerisola Lopez De Haro, Santiago; Latorre Canteli, Jesús María; Ramos Galán, Andrés;handle: 11531/5041
Artículos en revistas In this paper we apply stochastic dual dynamic programming decomposition to a nonconvex multistage stochastic hydrothermal model where the nonlinear water head effects on production and the nonlinear dependence between the reservoir head and the reservoir volume are modeled. The nonconvex constraints that represent the production function of a hydro plant are approximated by McCormick envelopes. These constraints are split into smaller regions and the McCormick envelopes are used for each region. We use binary variables for this disjunctive programming approach and solve the problem with a decomposition method. We resort to a variant of the L-shaped method for solving the MIP subproblem with binary variables at any stage inside the stochastic dual dynamic programming algorithm. A realistic large-scale case study is presented. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu78 citations 78 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2016Data sources: Recolector de Ciencia Abierta, RECOLECTAEuropean Journal of Operational ResearchArticle . 2012 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ejor.2011.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, Spain, ItalyPublisher:Elsevier BV Authors: Gaspari, Michele; Lorenzoni, Arturo; Frías, Pablo; Reneses, Javier;handle: 11577/3261557 , 11531/17382
Artículos en revistas Liberalization policies, the challenges of integrating distributed generation resources, and the recent flattening of electricity demand due to the economic crisis and technological change have led to lower returns for European electricity suppliers. Innovative and sustainable business models are needed to serve electricity customers while reflecting the operational needs of the system and maintaining supplier financial viability. This paper describes a novel model of Integrated Energy Services that encompasses distributed generation (DG) and demand response (DR) resources for industrial customers. We further reflect on some of the market opportunities and regulatory drivers for the development of similar schemes across Europe. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, Spain, ItalyPublisher:Elsevier BV Authors: Gaspari, Michele; Lorenzoni, Arturo; Frías, Pablo; Reneses, Javier;handle: 11577/3261557 , 11531/17382
Artículos en revistas Liberalization policies, the challenges of integrating distributed generation resources, and the recent flattening of electricity demand due to the economic crisis and technological change have led to lower returns for European electricity suppliers. Innovative and sustainable business models are needed to serve electricity customers while reflecting the operational needs of the system and maintaining supplier financial viability. This paper describes a novel model of Integrated Energy Services that encompasses distributed generation (DG) and demand response (DR) resources for industrial customers. We further reflect on some of the market opportunities and regulatory drivers for the development of similar schemes across Europe. info:eu-repo/semantics/publishedVersion
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2017Data sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jup.2017.03.002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu