- home
- Advanced Search
- Energy Research
- natural sciences
- PL
- Russian
- Energy Research
- natural sciences
- PL
- Russian
description Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:Zenodo Authors: S. Hrushko; L. Titarenko; A. Barkalov; I. Zeleneva;The purpose of this research is to determine the effective way of implementation of the control algorithm, as an important functional part of information and control computer systems. The search criterion is the minimum of internal hardware FPGA resources required for the control unit implementation. This criterion allows miniaturization of dimensions, improves reliability by reducing the number of interconnections inside the chip, and ensures the possibility of a compact arrangement of various system components, which is especially important when using the “system-on-chip” design technology. The control unit holds a prominent place in the digital information and control systems. A comparative analysis of two control unit models represented as a finite state machine with either hard or programmable logic was proposed. Advantages and disadvantages of both models were determined according to the peculiarities of the information and control system algorithms, and, it was proved that the FSM model with a programmable logic matched these peculiarities in a greater degree. The purpose of this study was achieved due to the application of the proposed method for the implementation of the FSM with the programmable logic using the embedded memory of the FPGA and ProASIC chips. The main result was a substantial decrease in the LUT number used. The experimental results were obtained applying the chips of the world's top manufacturers - Xilinx, Altera/Intel, Microsemi. The studies were carried out based on the onboard computing complex control algorithm.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
visibility 5visibility views 5 download downloads 3 Powered bymore_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:Zenodo Authors: S. Hrushko; L. Titarenko; A. Barkalov; I. Zeleneva;The purpose of this research is to determine the effective way of implementation of the control algorithm, as an important functional part of information and control computer systems. The search criterion is the minimum of internal hardware FPGA resources required for the control unit implementation. This criterion allows miniaturization of dimensions, improves reliability by reducing the number of interconnections inside the chip, and ensures the possibility of a compact arrangement of various system components, which is especially important when using the “system-on-chip” design technology. The control unit holds a prominent place in the digital information and control systems. A comparative analysis of two control unit models represented as a finite state machine with either hard or programmable logic was proposed. Advantages and disadvantages of both models were determined according to the peculiarities of the information and control system algorithms, and, it was proved that the FSM model with a programmable logic matched these peculiarities in a greater degree. The purpose of this study was achieved due to the application of the proposed method for the implementation of the FSM with the programmable logic using the embedded memory of the FPGA and ProASIC chips. The main result was a substantial decrease in the LUT number used. The experimental results were obtained applying the chips of the world's top manufacturers - Xilinx, Altera/Intel, Microsemi. The studies were carried out based on the onboard computing complex control algorithm.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
visibility 5visibility views 5 download downloads 3 Powered bymore_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2018Publisher:Zenodo Authors: Patiuk V.;Consider the propagation of electromagnetic energy through multiconductor three-phase high-voltage transmission line with arbitrary number of conductors. The mathematical formulation of the problem represents the system of partial differential equations known as transmission line equations. When constructing the capacitance matrix of an electric line, it is necessary to solve the boundary problems for the Laplace equation with nonlocal boundary conditions. The aim of this research is to develop a new method for constructing a potential coefficients matrix, which allows us to express the voltage vector in the wires through the charge vector. The application of this method leads to the necessity of solving a boundary value problem for Laplace equations with nonlocal boundary conditions. A new type of non-local boundary conditions has been identified, which has not been previously investigated. The boundary conditions of this type are represented by the contour integral over the boundary of the region from an unknown potential. In the general case, the obtained problem does not have a unique solution. The theorem of existence and uniqueness of the solution for the boundary value problem for the Laplace equation with nonlocal boundary conditions is proved. However, the requirement that the potential on the wire surface is constant allows us to prove the existence and uniqueness of the solution for considered problem. In order to illustrate the application of the developed approach we have solved numerically the problem for the sector-shaped cable with three cores. The values of potential and capacitive coefficients obtained by calculation are given. The error of the values of the diagonal elements of the matrices of potential and capacitive coefficients is estimated as less than 0.1%.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2018Publisher:Zenodo Authors: Patiuk V.;Consider the propagation of electromagnetic energy through multiconductor three-phase high-voltage transmission line with arbitrary number of conductors. The mathematical formulation of the problem represents the system of partial differential equations known as transmission line equations. When constructing the capacitance matrix of an electric line, it is necessary to solve the boundary problems for the Laplace equation with nonlocal boundary conditions. The aim of this research is to develop a new method for constructing a potential coefficients matrix, which allows us to express the voltage vector in the wires through the charge vector. The application of this method leads to the necessity of solving a boundary value problem for Laplace equations with nonlocal boundary conditions. A new type of non-local boundary conditions has been identified, which has not been previously investigated. The boundary conditions of this type are represented by the contour integral over the boundary of the region from an unknown potential. In the general case, the obtained problem does not have a unique solution. The theorem of existence and uniqueness of the solution for the boundary value problem for the Laplace equation with nonlocal boundary conditions is proved. However, the requirement that the potential on the wire surface is constant allows us to prove the existence and uniqueness of the solution for considered problem. In order to illustrate the application of the developed approach we have solved numerically the problem for the sector-shaped cable with three cores. The values of potential and capacitive coefficients obtained by calculation are given. The error of the values of the diagonal elements of the matrices of potential and capacitive coefficients is estimated as less than 0.1%.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2019Publisher:Zenodo Authors: Tirsu M.S.; Lupu M.L.; Postoronca Sv.A.;The paper aims to provide argumentation of centralized district heating system use from the consideration of harmlessness for both public health and environment, in comparison with the use of individual heating units, installed in residential areas of the Chisinau municipality. Proposed goal have been reached performing the comparison on quantitative harmful emissions resulting from the operation of these two types of heating, using emissions factors, deducted from the specific consumption of thermal energy. The issue's relevance is proved by the existence of considerable number of disconnected users from the centralized heating, though last years, this trend is decreasing. As regard to new buildings, they continue to give priority to the individual heating. Statistical data provided by specialized institutions of the municipality underlines the increased share of incidents of intoxication with combustion products, namely carbon oxide, followed by poisoning from gas leaks, shingles caused by explosions in violation of the operating rules of such equipment, also registering lethal cases. New results are the determination of the difference in emission values for both cases. The importance of the obtained results is that for the generation of thermal energy in a centralized heating system using cogeneration technology, harmful emissions into the environment are 28% less than when using individual heat supply systems. This received ascertainment could serve as an important argumentation for the obvious priority of the centralized heating system in the municipality versus the use of individual units.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2019Publisher:Zenodo Authors: Tirsu M.S.; Lupu M.L.; Postoronca Sv.A.;The paper aims to provide argumentation of centralized district heating system use from the consideration of harmlessness for both public health and environment, in comparison with the use of individual heating units, installed in residential areas of the Chisinau municipality. Proposed goal have been reached performing the comparison on quantitative harmful emissions resulting from the operation of these two types of heating, using emissions factors, deducted from the specific consumption of thermal energy. The issue's relevance is proved by the existence of considerable number of disconnected users from the centralized heating, though last years, this trend is decreasing. As regard to new buildings, they continue to give priority to the individual heating. Statistical data provided by specialized institutions of the municipality underlines the increased share of incidents of intoxication with combustion products, namely carbon oxide, followed by poisoning from gas leaks, shingles caused by explosions in violation of the operating rules of such equipment, also registering lethal cases. New results are the determination of the difference in emission values for both cases. The importance of the obtained results is that for the generation of thermal energy in a centralized heating system using cogeneration technology, harmful emissions into the environment are 28% less than when using individual heat supply systems. This received ascertainment could serve as an important argumentation for the obvious priority of the centralized heating system in the municipality versus the use of individual units.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:Zenodo Authors: S. Hrushko; L. Titarenko; A. Barkalov; I. Zeleneva;The purpose of this research is to determine the effective way of implementation of the control algorithm, as an important functional part of information and control computer systems. The search criterion is the minimum of internal hardware FPGA resources required for the control unit implementation. This criterion allows miniaturization of dimensions, improves reliability by reducing the number of interconnections inside the chip, and ensures the possibility of a compact arrangement of various system components, which is especially important when using the “system-on-chip” design technology. The control unit holds a prominent place in the digital information and control systems. A comparative analysis of two control unit models represented as a finite state machine with either hard or programmable logic was proposed. Advantages and disadvantages of both models were determined according to the peculiarities of the information and control system algorithms, and, it was proved that the FSM model with a programmable logic matched these peculiarities in a greater degree. The purpose of this study was achieved due to the application of the proposed method for the implementation of the FSM with the programmable logic using the embedded memory of the FPGA and ProASIC chips. The main result was a substantial decrease in the LUT number used. The experimental results were obtained applying the chips of the world's top manufacturers - Xilinx, Altera/Intel, Microsemi. The studies were carried out based on the onboard computing complex control algorithm.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
visibility 5visibility views 5 download downloads 3 Powered bymore_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:Zenodo Authors: S. Hrushko; L. Titarenko; A. Barkalov; I. Zeleneva;The purpose of this research is to determine the effective way of implementation of the control algorithm, as an important functional part of information and control computer systems. The search criterion is the minimum of internal hardware FPGA resources required for the control unit implementation. This criterion allows miniaturization of dimensions, improves reliability by reducing the number of interconnections inside the chip, and ensures the possibility of a compact arrangement of various system components, which is especially important when using the “system-on-chip” design technology. The control unit holds a prominent place in the digital information and control systems. A comparative analysis of two control unit models represented as a finite state machine with either hard or programmable logic was proposed. Advantages and disadvantages of both models were determined according to the peculiarities of the information and control system algorithms, and, it was proved that the FSM model with a programmable logic matched these peculiarities in a greater degree. The purpose of this study was achieved due to the application of the proposed method for the implementation of the FSM with the programmable logic using the embedded memory of the FPGA and ProASIC chips. The main result was a substantial decrease in the LUT number used. The experimental results were obtained applying the chips of the world's top manufacturers - Xilinx, Altera/Intel, Microsemi. The studies were carried out based on the onboard computing complex control algorithm.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
visibility 5visibility views 5 download downloads 3 Powered bymore_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3239172&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2018Publisher:Zenodo Authors: Patiuk V.;Consider the propagation of electromagnetic energy through multiconductor three-phase high-voltage transmission line with arbitrary number of conductors. The mathematical formulation of the problem represents the system of partial differential equations known as transmission line equations. When constructing the capacitance matrix of an electric line, it is necessary to solve the boundary problems for the Laplace equation with nonlocal boundary conditions. The aim of this research is to develop a new method for constructing a potential coefficients matrix, which allows us to express the voltage vector in the wires through the charge vector. The application of this method leads to the necessity of solving a boundary value problem for Laplace equations with nonlocal boundary conditions. A new type of non-local boundary conditions has been identified, which has not been previously investigated. The boundary conditions of this type are represented by the contour integral over the boundary of the region from an unknown potential. In the general case, the obtained problem does not have a unique solution. The theorem of existence and uniqueness of the solution for the boundary value problem for the Laplace equation with nonlocal boundary conditions is proved. However, the requirement that the potential on the wire surface is constant allows us to prove the existence and uniqueness of the solution for considered problem. In order to illustrate the application of the developed approach we have solved numerically the problem for the sector-shaped cable with three cores. The values of potential and capacitive coefficients obtained by calculation are given. The error of the values of the diagonal elements of the matrices of potential and capacitive coefficients is estimated as less than 0.1%.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2018Publisher:Zenodo Authors: Patiuk V.;Consider the propagation of electromagnetic energy through multiconductor three-phase high-voltage transmission line with arbitrary number of conductors. The mathematical formulation of the problem represents the system of partial differential equations known as transmission line equations. When constructing the capacitance matrix of an electric line, it is necessary to solve the boundary problems for the Laplace equation with nonlocal boundary conditions. The aim of this research is to develop a new method for constructing a potential coefficients matrix, which allows us to express the voltage vector in the wires through the charge vector. The application of this method leads to the necessity of solving a boundary value problem for Laplace equations with nonlocal boundary conditions. A new type of non-local boundary conditions has been identified, which has not been previously investigated. The boundary conditions of this type are represented by the contour integral over the boundary of the region from an unknown potential. In the general case, the obtained problem does not have a unique solution. The theorem of existence and uniqueness of the solution for the boundary value problem for the Laplace equation with nonlocal boundary conditions is proved. However, the requirement that the potential on the wire surface is constant allows us to prove the existence and uniqueness of the solution for considered problem. In order to illustrate the application of the developed approach we have solved numerically the problem for the sector-shaped cable with three cores. The values of potential and capacitive coefficients obtained by calculation are given. The error of the values of the diagonal elements of the matrices of potential and capacitive coefficients is estimated as less than 0.1%.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.2222387&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2019Publisher:Zenodo Authors: Tirsu M.S.; Lupu M.L.; Postoronca Sv.A.;The paper aims to provide argumentation of centralized district heating system use from the consideration of harmlessness for both public health and environment, in comparison with the use of individual heating units, installed in residential areas of the Chisinau municipality. Proposed goal have been reached performing the comparison on quantitative harmful emissions resulting from the operation of these two types of heating, using emissions factors, deducted from the specific consumption of thermal energy. The issue's relevance is proved by the existence of considerable number of disconnected users from the centralized heating, though last years, this trend is decreasing. As regard to new buildings, they continue to give priority to the individual heating. Statistical data provided by specialized institutions of the municipality underlines the increased share of incidents of intoxication with combustion products, namely carbon oxide, followed by poisoning from gas leaks, shingles caused by explosions in violation of the operating rules of such equipment, also registering lethal cases. New results are the determination of the difference in emission values for both cases. The importance of the obtained results is that for the generation of thermal energy in a centralized heating system using cogeneration technology, harmful emissions into the environment are 28% less than when using individual heat supply systems. This received ascertainment could serve as an important argumentation for the obvious priority of the centralized heating system in the municipality versus the use of individual units.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2019Publisher:Zenodo Authors: Tirsu M.S.; Lupu M.L.; Postoronca Sv.A.;The paper aims to provide argumentation of centralized district heating system use from the consideration of harmlessness for both public health and environment, in comparison with the use of individual heating units, installed in residential areas of the Chisinau municipality. Proposed goal have been reached performing the comparison on quantitative harmful emissions resulting from the operation of these two types of heating, using emissions factors, deducted from the specific consumption of thermal energy. The issue's relevance is proved by the existence of considerable number of disconnected users from the centralized heating, though last years, this trend is decreasing. As regard to new buildings, they continue to give priority to the individual heating. Statistical data provided by specialized institutions of the municipality underlines the increased share of incidents of intoxication with combustion products, namely carbon oxide, followed by poisoning from gas leaks, shingles caused by explosions in violation of the operating rules of such equipment, also registering lethal cases. New results are the determination of the difference in emission values for both cases. The importance of the obtained results is that for the generation of thermal energy in a centralized heating system using cogeneration technology, harmful emissions into the environment are 28% less than when using individual heat supply systems. This received ascertainment could serve as an important argumentation for the obvious priority of the centralized heating system in the municipality versus the use of individual units.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.5281/zenodo.3367069&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu