- home
- Advanced Search
- Energy Research
- clinical medicine
- 7. Clean energy
- Energy Research
- clinical medicine
- 7. Clean energy
description Publicationkeyboard_double_arrow_right Article , Journal 2021 United KingdomPublisher:Elsevier BV Authors: Stewart, Arthur D.; Gardiner, Matthew; MacDonald, Jonathan; Williams, Hector;pmid: 32871351
Building, bridge or wind turbine maintenance requires manual dexterity tasks by a specialist rope-access trained workforce via two principal means: harness suspension of individual workers from above, or deployment of a suspended platform or cradle from which workers access the structure to be maintained. Currently no published research compares accuracy and efficiency of simulated maintenance tasks between these modalities. This study investigated manual dexterity task performance of peg placement and shape delineation in seated, standing and suspended environments in 16 healthy controls and 26 professional rope-access trained individuals. Both seated and standing assessments were superior to those suspended, and height of suspension, total mass and years of experience had no influence on the task outcome. These findings suggest that, where feasible, cradle suspension mechanisms which permit standing maintenance are favourable in terms of task efficacy and where feasible, should be considered for deployment in wind energy and other engineering applications.
OpenAIR@RGU (Robert ... arrow_drop_down OpenAIR@RGU (Robert Gordon University, Aberdeen)Article . 2020License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apergo.2020.103247&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 3 citations 3 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert OpenAIR@RGU (Robert ... arrow_drop_down OpenAIR@RGU (Robert Gordon University, Aberdeen)Article . 2020License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apergo.2020.103247&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Article 2012Publisher:IEEE Authors: James D. Weiland; Boshuo Wang;pmid: 23367085
Previous studies reveal that the primary distribution of the current density is sharply enhanced at the edge of a disk electrode submerged into a semi-infinite space of conductive solution. The current enhancement will cause the double layer capacitance at the periphery of the electrode to be charged much faster compared to the center, and can also lead to severe corrosion at the edge. While several studies focused on the geometric design of the electrode to reduce this enhancement, we explore the feasibility of achieving similar effect by shaping the edges of the current input. The simulation uses finite element analysis software to solve the system of partial differential equations and results show that the edge enhancement could be greatly reduced without significantly changing the input efficacy of current and/or charge.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/embc.2012.6347150&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu4 citations 4 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/embc.2012.6347150&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2003Publisher:IOP Publishing Authors: Ted Lazo;pmid: 14582716
From its inception, the Nuclear Energy Agency (NEA), which is part of the broader Organisation for Economic Co-operation and Development, has contributed to the development of international radiological protection norms and standards. This continues today, in the form of studies and workshops to assist radiological protection policy makers, regulators and practitioners to develop concepts and approaches to help the international system of radiological protection, as recommended by the International Commission on Radiological Protection (ICRP), to evolve to better serve societal needs. The NEA's Committee on Radiation Protection and Public Health (CRPPH), in providing this support, has collaborated closely with the ICRP and strongly supports the current ICRP recommendation development process. In particular, active dialogue with a broad range of stakeholders is contributing to the evolution of concepts towards consensus on new ICRP recommendations. The CRPPH, as a body of ICRP recommendation practitioners, feels that the public, workers and the environment are well protected by the current radiological protection system, but agrees that a new consolidation and clarification of ICRP recommendations would be of value. The intent of the CRPPH in collaborating with ICRP is to develop a system of radiological protection that is simplified, more coherent, firmly based upon science and more clearly presented than the current system. This paper summarises the more detailed views of the CRPPH on the evolution of the system of radiological protection.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/0952-4746/23/3/301&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 2 citations 2 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/0952-4746/23/3/301&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2011Publisher:Wiley Shie Nishioka; Kana Matsubara; Ryosuke Kohno; Kenji Hotta; Mitsuhiko Kawashima; Teiji Nishio; Takashi Ogino; Taeko Matsuura;We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.PACS number: 87.56.‐v
Journal of Applied C... arrow_drop_down Journal of Applied Clinical Medical PhysicsArticle . 2011 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1120/jacmp.v12i2.3431&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 10 citations 10 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert Journal of Applied C... arrow_drop_down Journal of Applied Clinical Medical PhysicsArticle . 2011 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1120/jacmp.v12i2.3431&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 1984The noise level for working arc furnace has been measured. Arc furnaces were found to be the source of infrasounds and acoustic field. The sound pressure levels for infrasounds range from 55 to 77 dB. It has been showed that particular noise level includes the onethird-octave band with middle frequency 100 Hz. The sound pressure levels in this band range from 105 to 110 dB.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=6472092&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=6472092&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Article , Other literature type 2019Publisher:MDPI AG Publicly fundedLetizia D’Angelo; Noel Finnerty; Federico Seri; Alessandro Piccinini; Ronan Coffey; Carlos Tighe; PJ Mealy; Marc Mellotte; Marcus Keane;Global energy consumption has risen enormously over the past century due to population growth and increasing energy use per person. Industrial production consumes a significant portion of global energy resources. Thus, industrial sector’s investment in energy efficiency is critical to a sustainable future. For most global enterprises the consumption of energy and natural resources represents a major overhead and developing sustainable energy policies can represent a significant competitive advantage due to the growing price of energy and volatility of supply. This symbiotic relationship can lead to the mutual benefits of increasing industrial efficiency whilst allowing the transition to a sustainable renewables-based energy future and needs to be significantly harnessed. This paper describes a decision support framework to help industrial organisations make positive investment decisions on energy performance improvement projects.
https://doi.org/10.3... arrow_drop_down https://doi.org/10.3390/procee...Conference object . 2019 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/proceedings2019020022&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert https://doi.org/10.3... arrow_drop_down https://doi.org/10.3390/procee...Conference object . 2019 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/proceedings2019020022&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Report , Article , Other literature type , Journal 1999 United StatesPublisher:Office of Scientific and Technical Information (OSTI) Authors: Valentine, T.E.;Nondestructive assay methods that rely on measurement of correlated gamma rays from fission have been proposed as a means to determine the mass of fissile materials. Sensitivity studies for such measurements will require knowledge of the multiplicity of prompt gamma rays from fission; however, a very limited number of multiplicity distributions have been measured. A method is proposed to estimate the average number of gamma rays from any fission process by using the correlation of neutron and gamma emission in fission. Using this method, models for the total prompt gamma ray energy from fission adequately reproduce the measured value for thermal neutron induced fission of {sup 233}U. Likewise, the average energy of prompt gamma rays from fission has been adequately estimated using a simple linear model. Additionally, a method to estimate the multiplicity distribution of prompt gamma rays from fission is proposed based on a measured distribution for {sup 252}Cf. These methods are only approximate at best and should only be used for sensitivity studies. Measurements of the multiplicity distribution of prompt gamma rays from fission should be performed to determine the adequacy of the models proposed in this article.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.2172/753485&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 71 citations 71 popularity Top 10% influence Top 1% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.2172/753485&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Part of book or chapter of book , Article , Journal 2019Publisher:Brill | Nijhoff Authors: van der Ree, Kees;This chapter explores the nexus between climate change and jobs. For the International Labour Organization (ILO), the relevance of climate change and low carbon development has not always been evident. Member states and social partners have long been reluctant to include the transition to low carbon economies in the programme of work and commit resources to it. But in recent years, environmental issues have become a policy priority among ILO member states and social partners. Why, then, is climate change now more relevant than ever for the world of work? What are the current and forecasted employment and social implications of climate change and the policies for adaptation and mitigation? How can the distributional impact of the move to a low-carbon society be better understood and managed? In this respect, how relevant is the concept of ‘green jobs’? What policy approach has emerged within the ILO despite initial resistance and disagreement among constituents? Finally, what role could the ILO play in the future to promote social justice in the transition?
https://doi.org/10.1... arrow_drop_down https://doi.org/10.1163/978900...Part of book or chapter of book . 2019 . Peer-reviewedLicense: CC BY NCData sources: Crossrefhttps://brill.com/downloadpdf/...Part of book or chapter of bookLicense: CC BY NCData sources: UnpayWallRevue Internationale de Politique de DéveloppementArticle . 2019 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1163/9789004399013_013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 16 citations 16 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert https://doi.org/10.1... arrow_drop_down https://doi.org/10.1163/978900...Part of book or chapter of book . 2019 . Peer-reviewedLicense: CC BY NCData sources: Crossrefhttps://brill.com/downloadpdf/...Part of book or chapter of bookLicense: CC BY NCData sources: UnpayWallRevue Internationale de Politique de DéveloppementArticle . 2019 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1163/9789004399013_013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006Publisher:Elsevier BV Authors: Einar Sagstuen; Eirik Malinen; Einar Waldeland; Eli O. Hole;pmid: 16495132
Lithium formate electron paramagnetic resonance (EPR) dosimeters were irradiated using 60Co gamma-rays or fast neutrons to doses ranging from 5 to 20 Gy and investigated by EPR spectroscopy. Using a polynomial fitting procedure in order to accurately analyze peak-to-peak line widths of first derivative EPR spectra, dosimeters irradiated with neutrons had on average 4.4+/-0.9% broader EPR resonance lines than gamma-irradiated dosimeters. The increase in line width was slightly asymmetrical. Computer simulated first derivative polycrystalline EPR spectra of a *CO2- radical gave very good reconstructions of experimental spectra of irradiated dosimeters. The spectrum simulations could then be used as a tool to investigate the line broadening observed following neutron irradiation. It was shown that an increase in the simulated Lorentzian line width could explain both the observed line broadening and the asymmetrical effect. The ratio of the peak-to-peak amplitude of first derivative EPR spectra obtained at two different microwave powers (20 and 0.5 mW) was 7.8+/-1.2% higher for dosimeters irradiated with neutrons. The dependence of the spectrum amplitude on the microwave power was extensively investigated by fitting observations to an analytical non-linear model incorporating, among others, the spin-lattice (T1) and spin-spin (T2) relaxation times as fitting parameters. Neutron irradiation resulted in a reduction in T(2) in comparison with gamma-irradiation, while a smaller difference in T1 was found. The effects observed indicate increased local radical density following irradiation using high linear energy transfer (LET) neutrons as compared to low LET gamma-irradiation. A fingerprint of the LET may thus be found either by an analysis of the line width or of the dependence of the spectrum amplitude on the microwave power. Lithium formate is therefore a promising material for EPR dosimetry of high LET radiation.
Spectrochimica Acta ... arrow_drop_down Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefSpectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006Data sources: Europe PubMed CentralAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.saa.2005.10.017&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 23 citations 23 popularity Average influence Top 10% impulse Top 10% Powered by BIP!
more_vert Spectrochimica Acta ... arrow_drop_down Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefSpectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006Data sources: Europe PubMed CentralAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.saa.2005.10.017&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006Publisher:Oxford University Press (OUP) Authors: Shuzo Uehara; Hooshang Nikjoo;doi: 10.1269/jrr.47.69
pmid: 16571920
The paper describes the development of chemical modules simulating the prechemical and chemical stages of charged particle tracks in pure liquid water. These calculations are based on our physical track structure codes for electrons and ions (KURBUC, LEPHIST and LEAHIST) which provide the initial spatial distribution of H2O+, H2O* and subexcitation electrons at approximately 10(-15) s. We considered 11 species and 26 chemical reactions. A step-by-step Monte Carlo approach was adopted for the chemical stage between 10(-12) s and 10(-6) s. The chemistry codes enabled to simulate the non-homogeneous chemistry that pertains to electron, proton and alpha-particle tracks of various linear energy transfers (LET). Time-dependent yields of chemical species produced by electrons and ions of different energies were calculated. The calculated primary yields (G values at 10(-6) s) of 2.80 for OH and 2.59 for e(aq)- for 1 MeV electrons are in good agreement with the published values. The calculated G values at 10(-6) s for a wide range LETs from of 0.2 to 235 keV microm(-1) were obtained. The calculations show the LET dependence for OH and H2O2. The electron penetration ranges were calculated in order to discuss the role of low energy electrons.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1269/jrr.47.69&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 106 citations 106 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1269/jrr.47.69&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2021 United KingdomPublisher:Elsevier BV Authors: Stewart, Arthur D.; Gardiner, Matthew; MacDonald, Jonathan; Williams, Hector;pmid: 32871351
Building, bridge or wind turbine maintenance requires manual dexterity tasks by a specialist rope-access trained workforce via two principal means: harness suspension of individual workers from above, or deployment of a suspended platform or cradle from which workers access the structure to be maintained. Currently no published research compares accuracy and efficiency of simulated maintenance tasks between these modalities. This study investigated manual dexterity task performance of peg placement and shape delineation in seated, standing and suspended environments in 16 healthy controls and 26 professional rope-access trained individuals. Both seated and standing assessments were superior to those suspended, and height of suspension, total mass and years of experience had no influence on the task outcome. These findings suggest that, where feasible, cradle suspension mechanisms which permit standing maintenance are favourable in terms of task efficacy and where feasible, should be considered for deployment in wind energy and other engineering applications.
OpenAIR@RGU (Robert ... arrow_drop_down OpenAIR@RGU (Robert Gordon University, Aberdeen)Article . 2020License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apergo.2020.103247&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 3 citations 3 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert OpenAIR@RGU (Robert ... arrow_drop_down OpenAIR@RGU (Robert Gordon University, Aberdeen)Article . 2020License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apergo.2020.103247&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Article 2012Publisher:IEEE Authors: James D. Weiland; Boshuo Wang;pmid: 23367085
Previous studies reveal that the primary distribution of the current density is sharply enhanced at the edge of a disk electrode submerged into a semi-infinite space of conductive solution. The current enhancement will cause the double layer capacitance at the periphery of the electrode to be charged much faster compared to the center, and can also lead to severe corrosion at the edge. While several studies focused on the geometric design of the electrode to reduce this enhancement, we explore the feasibility of achieving similar effect by shaping the edges of the current input. The simulation uses finite element analysis software to solve the system of partial differential equations and results show that the edge enhancement could be greatly reduced without significantly changing the input efficacy of current and/or charge.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/embc.2012.6347150&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu4 citations 4 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/embc.2012.6347150&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2003Publisher:IOP Publishing Authors: Ted Lazo;pmid: 14582716
From its inception, the Nuclear Energy Agency (NEA), which is part of the broader Organisation for Economic Co-operation and Development, has contributed to the development of international radiological protection norms and standards. This continues today, in the form of studies and workshops to assist radiological protection policy makers, regulators and practitioners to develop concepts and approaches to help the international system of radiological protection, as recommended by the International Commission on Radiological Protection (ICRP), to evolve to better serve societal needs. The NEA's Committee on Radiation Protection and Public Health (CRPPH), in providing this support, has collaborated closely with the ICRP and strongly supports the current ICRP recommendation development process. In particular, active dialogue with a broad range of stakeholders is contributing to the evolution of concepts towards consensus on new ICRP recommendations. The CRPPH, as a body of ICRP recommendation practitioners, feels that the public, workers and the environment are well protected by the current radiological protection system, but agrees that a new consolidation and clarification of ICRP recommendations would be of value. The intent of the CRPPH in collaborating with ICRP is to develop a system of radiological protection that is simplified, more coherent, firmly based upon science and more clearly presented than the current system. This paper summarises the more detailed views of the CRPPH on the evolution of the system of radiological protection.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/0952-4746/23/3/301&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 2 citations 2 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/0952-4746/23/3/301&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2011Publisher:Wiley Shie Nishioka; Kana Matsubara; Ryosuke Kohno; Kenji Hotta; Mitsuhiko Kawashima; Teiji Nishio; Takashi Ogino; Taeko Matsuura;We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.PACS number: 87.56.‐v
Journal of Applied C... arrow_drop_down Journal of Applied Clinical Medical PhysicsArticle . 2011 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1120/jacmp.v12i2.3431&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 10 citations 10 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert Journal of Applied C... arrow_drop_down Journal of Applied Clinical Medical PhysicsArticle . 2011 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1120/jacmp.v12i2.3431&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 1984The noise level for working arc furnace has been measured. Arc furnaces were found to be the source of infrasounds and acoustic field. The sound pressure levels for infrasounds range from 55 to 77 dB. It has been showed that particular noise level includes the onethird-octave band with middle frequency 100 Hz. The sound pressure levels in this band range from 105 to 110 dB.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=6472092&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=6472092&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Article , Other literature type 2019Publisher:MDPI AG Publicly fundedLetizia D’Angelo; Noel Finnerty; Federico Seri; Alessandro Piccinini; Ronan Coffey; Carlos Tighe; PJ Mealy; Marc Mellotte; Marcus Keane;Global energy consumption has risen enormously over the past century due to population growth and increasing energy use per person. Industrial production consumes a significant portion of global energy resources. Thus, industrial sector’s investment in energy efficiency is critical to a sustainable future. For most global enterprises the consumption of energy and natural resources represents a major overhead and developing sustainable energy policies can represent a significant competitive advantage due to the growing price of energy and volatility of supply. This symbiotic relationship can lead to the mutual benefits of increasing industrial efficiency whilst allowing the transition to a sustainable renewables-based energy future and needs to be significantly harnessed. This paper describes a decision support framework to help industrial organisations make positive investment decisions on energy performance improvement projects.
https://doi.org/10.3... arrow_drop_down https://doi.org/10.3390/procee...Conference object . 2019 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/proceedings2019020022&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert https://doi.org/10.3... arrow_drop_down https://doi.org/10.3390/procee...Conference object . 2019 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/proceedings2019020022&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Report , Article , Other literature type , Journal 1999 United StatesPublisher:Office of Scientific and Technical Information (OSTI) Authors: Valentine, T.E.;Nondestructive assay methods that rely on measurement of correlated gamma rays from fission have been proposed as a means to determine the mass of fissile materials. Sensitivity studies for such measurements will require knowledge of the multiplicity of prompt gamma rays from fission; however, a very limited number of multiplicity distributions have been measured. A method is proposed to estimate the average number of gamma rays from any fission process by using the correlation of neutron and gamma emission in fission. Using this method, models for the total prompt gamma ray energy from fission adequately reproduce the measured value for thermal neutron induced fission of {sup 233}U. Likewise, the average energy of prompt gamma rays from fission has been adequately estimated using a simple linear model. Additionally, a method to estimate the multiplicity distribution of prompt gamma rays from fission is proposed based on a measured distribution for {sup 252}Cf. These methods are only approximate at best and should only be used for sensitivity studies. Measurements of the multiplicity distribution of prompt gamma rays from fission should be performed to determine the adequacy of the models proposed in this article.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.2172/753485&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 71 citations 71 popularity Top 10% influence Top 1% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.2172/753485&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Part of book or chapter of book , Article , Journal 2019Publisher:Brill | Nijhoff Authors: van der Ree, Kees;This chapter explores the nexus between climate change and jobs. For the International Labour Organization (ILO), the relevance of climate change and low carbon development has not always been evident. Member states and social partners have long been reluctant to include the transition to low carbon economies in the programme of work and commit resources to it. But in recent years, environmental issues have become a policy priority among ILO member states and social partners. Why, then, is climate change now more relevant than ever for the world of work? What are the current and forecasted employment and social implications of climate change and the policies for adaptation and mitigation? How can the distributional impact of the move to a low-carbon society be better understood and managed? In this respect, how relevant is the concept of ‘green jobs’? What policy approach has emerged within the ILO despite initial resistance and disagreement among constituents? Finally, what role could the ILO play in the future to promote social justice in the transition?
https://doi.org/10.1... arrow_drop_down https://doi.org/10.1163/978900...Part of book or chapter of book . 2019 . Peer-reviewedLicense: CC BY NCData sources: Crossrefhttps://brill.com/downloadpdf/...Part of book or chapter of bookLicense: CC BY NCData sources: UnpayWallRevue Internationale de Politique de DéveloppementArticle . 2019 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1163/9789004399013_013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 16 citations 16 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert https://doi.org/10.1... arrow_drop_down https://doi.org/10.1163/978900...Part of book or chapter of book . 2019 . Peer-reviewedLicense: CC BY NCData sources: Crossrefhttps://brill.com/downloadpdf/...Part of book or chapter of bookLicense: CC BY NCData sources: UnpayWallRevue Internationale de Politique de DéveloppementArticle . 2019 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1163/9789004399013_013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006Publisher:Elsevier BV Authors: Einar Sagstuen; Eirik Malinen; Einar Waldeland; Eli O. Hole;pmid: 16495132
Lithium formate electron paramagnetic resonance (EPR) dosimeters were irradiated using 60Co gamma-rays or fast neutrons to doses ranging from 5 to 20 Gy and investigated by EPR spectroscopy. Using a polynomial fitting procedure in order to accurately analyze peak-to-peak line widths of first derivative EPR spectra, dosimeters irradiated with neutrons had on average 4.4+/-0.9% broader EPR resonance lines than gamma-irradiated dosimeters. The increase in line width was slightly asymmetrical. Computer simulated first derivative polycrystalline EPR spectra of a *CO2- radical gave very good reconstructions of experimental spectra of irradiated dosimeters. The spectrum simulations could then be used as a tool to investigate the line broadening observed following neutron irradiation. It was shown that an increase in the simulated Lorentzian line width could explain both the observed line broadening and the asymmetrical effect. The ratio of the peak-to-peak amplitude of first derivative EPR spectra obtained at two different microwave powers (20 and 0.5 mW) was 7.8+/-1.2% higher for dosimeters irradiated with neutrons. The dependence of the spectrum amplitude on the microwave power was extensively investigated by fitting observations to an analytical non-linear model incorporating, among others, the spin-lattice (T1) and spin-spin (T2) relaxation times as fitting parameters. Neutron irradiation resulted in a reduction in T(2) in comparison with gamma-irradiation, while a smaller difference in T1 was found. The effects observed indicate increased local radical density following irradiation using high linear energy transfer (LET) neutrons as compared to low LET gamma-irradiation. A fingerprint of the LET may thus be found either by an analysis of the line width or of the dependence of the spectrum amplitude on the microwave power. Lithium formate is therefore a promising material for EPR dosimetry of high LET radiation.
Spectrochimica Acta ... arrow_drop_down Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefSpectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006Data sources: Europe PubMed CentralAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.saa.2005.10.017&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 23 citations 23 popularity Average influence Top 10% impulse Top 10% Powered by BIP!
more_vert Spectrochimica Acta ... arrow_drop_down Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefSpectrochimica Acta Part A Molecular and Biomolecular SpectroscopyArticle . 2006Data sources: Europe PubMed CentralAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.saa.2005.10.017&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006Publisher:Oxford University Press (OUP) Authors: Shuzo Uehara; Hooshang Nikjoo;doi: 10.1269/jrr.47.69
pmid: 16571920
The paper describes the development of chemical modules simulating the prechemical and chemical stages of charged particle tracks in pure liquid water. These calculations are based on our physical track structure codes for electrons and ions (KURBUC, LEPHIST and LEAHIST) which provide the initial spatial distribution of H2O+, H2O* and subexcitation electrons at approximately 10(-15) s. We considered 11 species and 26 chemical reactions. A step-by-step Monte Carlo approach was adopted for the chemical stage between 10(-12) s and 10(-6) s. The chemistry codes enabled to simulate the non-homogeneous chemistry that pertains to electron, proton and alpha-particle tracks of various linear energy transfers (LET). Time-dependent yields of chemical species produced by electrons and ions of different energies were calculated. The calculated primary yields (G values at 10(-6) s) of 2.80 for OH and 2.59 for e(aq)- for 1 MeV electrons are in good agreement with the published values. The calculated G values at 10(-6) s for a wide range LETs from of 0.2 to 235 keV microm(-1) were obtained. The calculations show the LET dependence for OH and H2O2. The electron penetration ranges were calculated in order to discuss the role of low energy electrons.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1269/jrr.47.69&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 106 citations 106 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1269/jrr.47.69&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu