- home
- Advanced Search
Filters
Access
Type
Year range
-chevron_right GO- This year
- Last 5 years
- Last 10 years
Field of Science
SDG [Beta]
Country
Source
Research community
Organization
- Energy Research
- Energy Research
description Publicationkeyboard_double_arrow_right Article 2024Publisher:MDPI AG Authors: Abdullah Abdurrahman Al-Saloli; Faris E. Alfaris;Large-scale photovoltaic (PV) systems are being widely deployed to meet global environmental goals and renewable energy targets. Advances in PV technology have driven investment in the electric sector. However, as the size of PV arrays grows, more obstacles and challenges emerge. The primary obstacles are the occurrence of direct current (DC) faults and shading in a large array of PV panels, where any malfunction in a single panel can have a detrimental impact on the overall output power of the entire series-connected PV string and therefore the PV array. Due to the abrupt and frequent fluctuations in power, beside the low-PV systems’ moment of inertia, various technical problems may arise at the point of common coupling (PCC) of grid-connected PV generations, such as frequency and voltage stability, power efficiency, voltage sag, harmonic distortion, and other power quality factors. The majority of the suggested solutions were deficient in several crucial transient operating features and cost feasibility; therefore, this paper introduces a novel power electronic DC–DC converter that seeks to mitigate these effects by compensating for the decrease in current on the DC side of the system. The suggested solution was derived from the dual-source voltage-fed quasi-Z-source inverter (VF-qZSI), where the PV generation power can be supported by an energy storage element. This paper also presents the system architecture and the corresponding power switching control. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate the feasibility and capability of the proposed scheme, which contributes in suppressing the peak of the transient power-to-time variation (dP/dt) by 72% and reducing its normalized root-mean-square error by about 38%, with an AC current total harmonic distortion (THD) of only 1.04%.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/electronics13214312&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/electronics13214312&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:MDPI AG Authors: Faris E. Alfaris; Essam A. Al-Ammar; Ghazi A. Ghazi; Ahmed A. AL-Katheri;doi: 10.3390/su16156454
As a result of global efforts to combat the rise in global climate change and carbon dioxide emissions, there has been a substantial increase in renewable energy investment for both residential and utility power generation. Solar power facilities are estimated to be among the major contributors to global decarbonization in terms of capacity by 2050. Consequently, the majority of economically significant countries are progressively implementing utility-scale photovoltaic (U-PV) systems. Nevertheless, a major obstacle to the expansion of U-PV generation is the identification and assessment of direct current (DC) faults in the extensive array of PV panels. In order to address this obstacle, it is imperative to provide an evaluation method that can accurately and cost-effectively identify and locate potential DC faults in PV arrays. Therefore, many studies attempted to utilize thermal cameras, voltage and current sensors, power databases, and other detecting elements; however, some of these technologies provide extra hurdles in terms of the quantity and expense of the utilized hardware equipment. This work presents a sophisticated system that aims to diagnose and locate various types of PV faults, such as line-to-ground, line-to-line, inter-string, open-circuit, and partial shading events, within a PV array strings down to a module level. This study primarily depends on three crucial indicators: precise calculation of the PV array output power and current, optimal placement of a limited number of voltage sensors, and execution of specifically specified tests. The estimation of PV array power, along with selectively placed voltage sensors, minimizes the time and equipment required for fault detection and diagnosis. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate that the proposed approach can accurately diagnose and localize faults with only NS/2 voltage sensors, where NS is the number of PV array parallel strings.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16156454&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16156454&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2023Publisher:MDPI AG Authors: Faris E. Alfaris;doi: 10.3390/en16031287
Deployment of photovoltaic (PV) systems has recently been encouraged for large-scale and small-scale businesses in order to meet the global green energy targets. However, one of the most significant hurdles that limits the spread of PV applications is the dust accumulated on the PV panels’ surfaces, especially in desert regions. Numerous studies sought the use of cameras, sensors, power datasets, and other detection elements to detect the dust on PV panels; however, these methods pose more maintenance, accuracy, and economic challenges. Therefore, this paper proposes an intelligent system to detect the dust level on the PV panels to optimally operate the attached dust cleaning units (DCUs). Unlike previous strategies, this study utilizes the expanded knowledge and collected data for solar irradiation and PV-generated power, along with the forecasted ambient temperature. An expert artificial intelligence (AI) computational system, adopted with the MATLAB platform, is utilized for a high level of data prediction and processing. The AI was used in this study in order to estimate the unprovided information, emulate the provided measurements, and accommodate more input/output data. The feasibility of the proposed system is investigated using actual field data during all possible weather conditions.
Energies arrow_drop_down EnergiesOther literature type . 2023License: CC BYFull-Text: http://www.mdpi.com/1996-1073/16/3/1287/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/en16031287&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 16 citations 16 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energies arrow_drop_down EnergiesOther literature type . 2023License: CC BYFull-Text: http://www.mdpi.com/1996-1073/16/3/1287/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/en16031287&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:MDPI AG Authors: Faris E. Alfaris; Faris Almutairi;doi: 10.3390/su16051825
The share of renewable energy resources in modern electrical power networks is increasing in order to meet environmental and technical targets. Consequently, energy researchers and power providers have been focusing on optimizing the integration of renewable energy into existing power grids. One of the most significant growing applications of renewable energy resources is residential photovoltaic (PV) systems; therefore, this paper discusses a new methodology to enhance the utilization of small-scale and medium-scale PV systems. For this purpose, this study proposes a user-friendly interface to help novice users optimally design their own PV projects with the highest possible utilization of the installed panels. Unlike the commercially available design tools, the proposed interface in this paper provides a higher degree-of-freedom computational process, as well as the option of improving the generated power quality, while maintaining the simplicity of the required tools and inputs. The proposed methodology mainly relies on a deep mathematical analysis considering different generation and consumption aspects, such as the load profile, time of usage, ambient temperature, PV system specifications and location. Furthermore, the mechanism of integrating a small portion of Energy Storage Systems (ESSs), to improve the quality of the extracted power, is also discussed in this study. The user interface provides the ability to estimate optimal ESS usage versus the estimated price when energy is urgently required. The case study was conducted in Riyadh, Saudi Arabia, and the results showed an essential improvement in the efficiency, solar fraction and power quality of the studied PV project, which can be extended to other home and distributed generation (DG) scales.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16051825&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16051825&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article 2024Publisher:MDPI AG Authors: Abdullah Abdurrahman Al-Saloli; Faris E. Alfaris;Large-scale photovoltaic (PV) systems are being widely deployed to meet global environmental goals and renewable energy targets. Advances in PV technology have driven investment in the electric sector. However, as the size of PV arrays grows, more obstacles and challenges emerge. The primary obstacles are the occurrence of direct current (DC) faults and shading in a large array of PV panels, where any malfunction in a single panel can have a detrimental impact on the overall output power of the entire series-connected PV string and therefore the PV array. Due to the abrupt and frequent fluctuations in power, beside the low-PV systems’ moment of inertia, various technical problems may arise at the point of common coupling (PCC) of grid-connected PV generations, such as frequency and voltage stability, power efficiency, voltage sag, harmonic distortion, and other power quality factors. The majority of the suggested solutions were deficient in several crucial transient operating features and cost feasibility; therefore, this paper introduces a novel power electronic DC–DC converter that seeks to mitigate these effects by compensating for the decrease in current on the DC side of the system. The suggested solution was derived from the dual-source voltage-fed quasi-Z-source inverter (VF-qZSI), where the PV generation power can be supported by an energy storage element. This paper also presents the system architecture and the corresponding power switching control. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate the feasibility and capability of the proposed scheme, which contributes in suppressing the peak of the transient power-to-time variation (dP/dt) by 72% and reducing its normalized root-mean-square error by about 38%, with an AC current total harmonic distortion (THD) of only 1.04%.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/electronics13214312&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/electronics13214312&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:MDPI AG Authors: Faris E. Alfaris; Essam A. Al-Ammar; Ghazi A. Ghazi; Ahmed A. AL-Katheri;doi: 10.3390/su16156454
As a result of global efforts to combat the rise in global climate change and carbon dioxide emissions, there has been a substantial increase in renewable energy investment for both residential and utility power generation. Solar power facilities are estimated to be among the major contributors to global decarbonization in terms of capacity by 2050. Consequently, the majority of economically significant countries are progressively implementing utility-scale photovoltaic (U-PV) systems. Nevertheless, a major obstacle to the expansion of U-PV generation is the identification and assessment of direct current (DC) faults in the extensive array of PV panels. In order to address this obstacle, it is imperative to provide an evaluation method that can accurately and cost-effectively identify and locate potential DC faults in PV arrays. Therefore, many studies attempted to utilize thermal cameras, voltage and current sensors, power databases, and other detecting elements; however, some of these technologies provide extra hurdles in terms of the quantity and expense of the utilized hardware equipment. This work presents a sophisticated system that aims to diagnose and locate various types of PV faults, such as line-to-ground, line-to-line, inter-string, open-circuit, and partial shading events, within a PV array strings down to a module level. This study primarily depends on three crucial indicators: precise calculation of the PV array output power and current, optimal placement of a limited number of voltage sensors, and execution of specifically specified tests. The estimation of PV array power, along with selectively placed voltage sensors, minimizes the time and equipment required for fault detection and diagnosis. The feasibility of the proposed method is investigated with real field data and the PSCAD simulation platform during all possible weather conditions and array faults. The results demonstrate that the proposed approach can accurately diagnose and localize faults with only NS/2 voltage sensors, where NS is the number of PV array parallel strings.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16156454&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16156454&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2023Publisher:MDPI AG Authors: Faris E. Alfaris;doi: 10.3390/en16031287
Deployment of photovoltaic (PV) systems has recently been encouraged for large-scale and small-scale businesses in order to meet the global green energy targets. However, one of the most significant hurdles that limits the spread of PV applications is the dust accumulated on the PV panels’ surfaces, especially in desert regions. Numerous studies sought the use of cameras, sensors, power datasets, and other detection elements to detect the dust on PV panels; however, these methods pose more maintenance, accuracy, and economic challenges. Therefore, this paper proposes an intelligent system to detect the dust level on the PV panels to optimally operate the attached dust cleaning units (DCUs). Unlike previous strategies, this study utilizes the expanded knowledge and collected data for solar irradiation and PV-generated power, along with the forecasted ambient temperature. An expert artificial intelligence (AI) computational system, adopted with the MATLAB platform, is utilized for a high level of data prediction and processing. The AI was used in this study in order to estimate the unprovided information, emulate the provided measurements, and accommodate more input/output data. The feasibility of the proposed system is investigated using actual field data during all possible weather conditions.
Energies arrow_drop_down EnergiesOther literature type . 2023License: CC BYFull-Text: http://www.mdpi.com/1996-1073/16/3/1287/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/en16031287&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 16 citations 16 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energies arrow_drop_down EnergiesOther literature type . 2023License: CC BYFull-Text: http://www.mdpi.com/1996-1073/16/3/1287/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/en16031287&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:MDPI AG Authors: Faris E. Alfaris; Faris Almutairi;doi: 10.3390/su16051825
The share of renewable energy resources in modern electrical power networks is increasing in order to meet environmental and technical targets. Consequently, energy researchers and power providers have been focusing on optimizing the integration of renewable energy into existing power grids. One of the most significant growing applications of renewable energy resources is residential photovoltaic (PV) systems; therefore, this paper discusses a new methodology to enhance the utilization of small-scale and medium-scale PV systems. For this purpose, this study proposes a user-friendly interface to help novice users optimally design their own PV projects with the highest possible utilization of the installed panels. Unlike the commercially available design tools, the proposed interface in this paper provides a higher degree-of-freedom computational process, as well as the option of improving the generated power quality, while maintaining the simplicity of the required tools and inputs. The proposed methodology mainly relies on a deep mathematical analysis considering different generation and consumption aspects, such as the load profile, time of usage, ambient temperature, PV system specifications and location. Furthermore, the mechanism of integrating a small portion of Energy Storage Systems (ESSs), to improve the quality of the extracted power, is also discussed in this study. The user interface provides the ability to estimate optimal ESS usage versus the estimated price when energy is urgently required. The case study was conducted in Riyadh, Saudi Arabia, and the results showed an essential improvement in the efficiency, solar fraction and power quality of the studied PV project, which can be extended to other home and distributed generation (DG) scales.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16051825&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su16051825&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu