- home
- Advanced Search
Filters
Access
Type
Year range
-chevron_right GO- This year
- Last 5 years
- Last 10 years
Field of Science
SDG [Beta]
Country
Source
Research community
Organization
- Energy Research
- Energy Research
description Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV Authors: Jalil Shaeri; Mohammadjavad Mahdavinejad; Mohammad Hossein Pourghasemian;Journal of Building ... arrow_drop_down Journal of Building EngineeringArticle . 2022 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jobe.2022.105041&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu5 citations 5 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Journal of Building ... arrow_drop_down Journal of Building EngineeringArticle . 2022 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jobe.2022.105041&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Conference object , Journal , Other literature type 2019Publisher:MDPI AG Authors: Jalil Shaeri; Mahmood Yaghoubi; Amin Habibi; Ata Chokhachian;doi: 10.3390/su11020311
Extensive cost in the building industry comes from cooling and heating to create thermal comfort. Hence, it is necessary to utilize passive solutions, in addition to suitable design, in order to reduce energy consumption. This research attempts to investigate the impact of archetype patterns in office buildings on annual energy consumption for cooling, heating and daylight loads. For this purpose, the DesignBuilder software was used to compare the forms. In this study, four conventional construction forms were considered, including the single and dense form, central courtyard buildings, U form and linear form, and each was considered with two, four and six-stories. Forms were simulated in the three cities of Bushehr, Shiraz and Tabriz, with hot-humid, hot-dry and cold climates, respectively. The results revealed that the office building with a linear form in Bushehr had the lowest energy consumption in the two and four-story forms, and also in the six-story form, the central courtyard form had the lowest energy consumption. Additionally, the central courtyard forms in Tabriz and Shiraz had the lowest energy consumption in all cases. Finally, the linear form possessed the most natural daylight through all of the studied cases for the three cities in terms of natural light gain.
Sustainability arrow_drop_down SustainabilityOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2071-1050/11/2/311/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su11020311&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 11 citations 11 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Sustainability arrow_drop_down SustainabilityOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2071-1050/11/2/311/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su11020311&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:MDPI AG Authors: Jalil Shaeri; Amin Habibi; Mahmood Yaghoubi; Ata Chokhachian;About half of the energy loss in buildings is wasted through windows. Determining the optimum window-to-wall ratio (WWR) for different building facades would reduce such energy losses. The optimum WWR is the window area that minimizes the total annual energy of cooling, heating, and lighting. The purpose of this study is to investigate the optimum WWR of different facades of an office building. For this purpose, a sample building is simulated by means of DesignBuilder software in order to investigate the annual solar heat gain, cooling load, heating load, and lighting consumption for the three cities of Bushehr, Shiraz, and Tabriz, and optimum window areas of office buildings for the three cities are determined. Based on the results, the optimum window area for the north building facade for all climates is 20–30%. This amount for the southern facade of the building in Bushehr, Shiraz, and Tabriz is, respectively, 20–30%, 10–30%, and 20–50%. The optimum window area for the eastern and western building facades in Bushehr is 30–50%; in Tabriz it is 40–70%, and in Shiraz it is 20–60% and 40–70%, respectively. The difference between the maximum and minimum energy consumption with different window areas in Bushehr and Shiraz is 20–100% and in Tabriz it is 16–25%.
Environments arrow_drop_down EnvironmentsOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2076-3298/6/4/45/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/environments6040045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 45 citations 45 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Environments arrow_drop_down EnvironmentsOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2076-3298/6/4/45/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/environments6040045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV Authors: Jalil Shaeri; Mohammadjavad Mahdavinejad; Mohammad Hossein Pourghasemian;Journal of Building ... arrow_drop_down Journal of Building EngineeringArticle . 2022 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jobe.2022.105041&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu5 citations 5 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Journal of Building ... arrow_drop_down Journal of Building EngineeringArticle . 2022 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.jobe.2022.105041&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Conference object , Journal , Other literature type 2019Publisher:MDPI AG Authors: Jalil Shaeri; Mahmood Yaghoubi; Amin Habibi; Ata Chokhachian;doi: 10.3390/su11020311
Extensive cost in the building industry comes from cooling and heating to create thermal comfort. Hence, it is necessary to utilize passive solutions, in addition to suitable design, in order to reduce energy consumption. This research attempts to investigate the impact of archetype patterns in office buildings on annual energy consumption for cooling, heating and daylight loads. For this purpose, the DesignBuilder software was used to compare the forms. In this study, four conventional construction forms were considered, including the single and dense form, central courtyard buildings, U form and linear form, and each was considered with two, four and six-stories. Forms were simulated in the three cities of Bushehr, Shiraz and Tabriz, with hot-humid, hot-dry and cold climates, respectively. The results revealed that the office building with a linear form in Bushehr had the lowest energy consumption in the two and four-story forms, and also in the six-story form, the central courtyard form had the lowest energy consumption. Additionally, the central courtyard forms in Tabriz and Shiraz had the lowest energy consumption in all cases. Finally, the linear form possessed the most natural daylight through all of the studied cases for the three cities in terms of natural light gain.
Sustainability arrow_drop_down SustainabilityOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2071-1050/11/2/311/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su11020311&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 11 citations 11 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Sustainability arrow_drop_down SustainabilityOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2071-1050/11/2/311/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su11020311&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:MDPI AG Authors: Jalil Shaeri; Amin Habibi; Mahmood Yaghoubi; Ata Chokhachian;About half of the energy loss in buildings is wasted through windows. Determining the optimum window-to-wall ratio (WWR) for different building facades would reduce such energy losses. The optimum WWR is the window area that minimizes the total annual energy of cooling, heating, and lighting. The purpose of this study is to investigate the optimum WWR of different facades of an office building. For this purpose, a sample building is simulated by means of DesignBuilder software in order to investigate the annual solar heat gain, cooling load, heating load, and lighting consumption for the three cities of Bushehr, Shiraz, and Tabriz, and optimum window areas of office buildings for the three cities are determined. Based on the results, the optimum window area for the north building facade for all climates is 20–30%. This amount for the southern facade of the building in Bushehr, Shiraz, and Tabriz is, respectively, 20–30%, 10–30%, and 20–50%. The optimum window area for the eastern and western building facades in Bushehr is 30–50%; in Tabriz it is 40–70%, and in Shiraz it is 20–60% and 40–70%, respectively. The difference between the maximum and minimum energy consumption with different window areas in Bushehr and Shiraz is 20–100% and in Tabriz it is 16–25%.
Environments arrow_drop_down EnvironmentsOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2076-3298/6/4/45/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/environments6040045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 45 citations 45 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Environments arrow_drop_down EnvironmentsOther literature type . 2019License: CC BYFull-Text: http://www.mdpi.com/2076-3298/6/4/45/pdfData sources: Multidisciplinary Digital Publishing Instituteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/environments6040045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu