- home
- Advanced Search
- Energy Research
- Closed Access
- Restricted
- 13. Climate action
- 14. Life underwater
- Energy Conversion and Management
- Energy Research
- Closed Access
- Restricted
- 13. Climate action
- 14. Life underwater
- Energy Conversion and Management
description Publicationkeyboard_double_arrow_right Article , Journal 2015Publisher:Elsevier BV Yuechao Deng; Zhongliang Liu; Yaohua Zhao; Lincheng Wang;Zhenhua Quan;
Zhenhua Quan
Zhenhua Quan in OpenAIREAbstract This paper presented a novel method of dissipating solar photovoltaic heat based on the technology of micro-heat-pipe array and the utilization of photovoltaic-cell waste heat. This novel technology solved the problems of low PV electrical efficiency and thermal failure caused by high cell temperature, greatly increased the comprehensive utilization efficiency of solar energy, and extended the service life of photovoltaic modules. One-year experiments were conducted to investigate the electrical and thermal performance of a forced-circulation, household-type photovoltaic/thermal system based on micro-heat-pipe array in Beijing, China. Test results showed that on the four typical days in different seasons, the average electrical efficiencies were 13.76%, 11.92%, 13.71%, and 14.65%; the average thermal efficiencies were 31.62%, 33.07%, 24.99%, and 17.24%; and the average total efficiencies were 45.38%, 44.99%, 38.70%, 31.89%, respectively. The system met the demand of power supply on sunny days and the demand of hot water between March and November, except in cloudy days. These experimental results can provide basis and reference for practical applications of the system.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2015.09.067&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 58 citations 58 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2015.09.067&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV Authors: El-Bidairi, Kutaiba S; Duc Nguyen, Hung;Jayasinghe, S.D.G;
Mahmoud, Thair S; +1 AuthorsJayasinghe, S.D.G
Jayasinghe, S.D.G in OpenAIREEl-Bidairi, Kutaiba S; Duc Nguyen, Hung;Jayasinghe, S.D.G;
Mahmoud, Thair S; Penesis, Irene;Jayasinghe, S.D.G
Jayasinghe, S.D.G in OpenAIREMicrogrids are increasingly being used as a platform to integrate distributed generation such as renewable energy sources and (RESs) conventional sources in both grid-connected and isolated power systems. Due to the inherent intermittent nature of RESs, energy storage systems (ESSs) that can absorb fluctuations have become inevitable. Nevertheless, large capacities of ESSs increase the initial cost while small capacities lead to instabilities and increase in the cost of conventional fuels. Therefore, finding the optimal size of the ESS for a given application is essential for the reliable, efficient and economical operation of a microgrid. Once the battery size is decided, maintaining its energy at appropriate levels is essential to ensure stable and safe operation of the microgrid. This paper presents a novel expert fuzzy system - grey wolf optimization (FL-GWO) based intelligent meta-heuristic method for battery sizing and energy management. The proposed energy management operation is carried out by a Grey Wolf Optimiser (GWO) that is helped to set the membership functions and rules of the fuzzy logic expert system. The unit commitment (UC) issue, which is essential for the proper operation of the isolated microgrid, has been additionally considered in this paper. To verify the performance of the proposed method, results are compared with the rules-based method and traditional GWO algorithm. It has been proven from the results that the FL-GWO has a significant convergence property and capability to minimize the Levelized Cost Of Electricity (LCOE) by 14.13% and 24.15% compared with conventional GWO algorithm and rules-based method, respectively. The weather conditions for different climates is used to verify the performance of the intelligent energy management method under different operating scenarios. The results show that the intelligent online multi-objective energy management strategy is capable of managing a smooth power flow with the same optimal configuration in the isolated microgrid, minimising the fossil fuel utilisation and reducing the CO2 emission level.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversity of Tasmania: UTas ePrintsArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)Edith Cowan University (ECU, Australia): Research OnlineArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 115 citations 115 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversity of Tasmania: UTas ePrintsArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)Edith Cowan University (ECU, Australia): Research OnlineArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Alexander Tremel; Stefan Becker;Oliver Walter;
Oliver Walter; +2 AuthorsOliver Walter
Oliver Walter in OpenAIREAlexander Tremel; Stefan Becker;Oliver Walter;
Oliver Walter; Marco Prenzel; Jochen Schaefer;Oliver Walter
Oliver Walter in OpenAIREAbstract Hybrid energy storage is a multi-modal approach to store and supply different forms of energy (electricity, heat, cold) simultaneously. This is an important sector coupling approach and enables large scale flexibility for a deep decarbonization of energy systems. Two different proposed energy storages – power-to-heat-to-X energy storage (PHXES) and pumped thermal energy storage (PTES) – are investigated in detail in this work towards their potential towards a hybrid deployment. The techno-economic analysis includes thermodynamic flowsheet simulations and unified cost estimations based on the used equipment. It is shown that the main input data set (e.g. working fluid selection, turbomachinery efficiency, pinch temperatures) has a strong influence on storage roundtrip efficiency in the thermodynamic simulations, but also on storage costs. Cost decrease and performance increase can be conflicting development targets, and it is not clear if future energy systems rather require technologies with the highest storage efficiencies or if low cost is an important prerequisite. PHXES and three variants of PTES are implemented into a simplified energy system model of the city of Hamburg that comprises the electric load and heat demand of the district heating system. Two scenarios (fossil benchmark and 80% decarbonization) are used to select the technologies and their capacities that allow the most cost-effective energy supply solution by a linear-programming optimization procedure. Large scale renewable power generation and hybrid energy storage play the major roles in the decarbonization scenario. PHXES with a storage capacity of 69 GWh, hot water storage (3.6 GWh) and a battery system (430 MWh) are part of the cost-optimal solution. A cost sensitivity analysis shows that a total cost reduction of 60–80% is required for PTES to become competitive in this model scenario.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2020.112955&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 18 citations 18 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2020 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2020.112955&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1987Publisher:Elsevier BV Authors: A.V. Gholap; C.E. Okeke; A.C. Anuforom;We have studied the response of the efficiency and short-circuit current of an array of silicon solar cells to changes in intensity of solar radiation under tropical atmospheric conditions. The investigation was carried out simultaneously at two different geographical locations in Nigeria: Enugu (6.20°N, 7.30°E) and Port Harcourt (4.43°N, 7.10°E) (Port Harcourt is located very close to the sea, while Enugu is far away from the sea). Data collected from the two locations clearly reveal that the mean optimum efficiency is not constant, but decreases exponentially as the intensity of solar radiation increases. The short-circuit current, on the other hand, increases non-linearly with intensity of solar radiation and approaches some constant maximum value under very high insolation. The change in efficiency is above 70% as the intensity of solar radiation changes from 100 to 800 W m−2. An empirical equation, relating the mean optimum efficiency to intensity of solar radiation, and an empirical equation, relating the mean short-circuit current to intensity of solar radiation, have been proposed. No previous similar work is available for comparison, but our results are consistent with the well-established fact that under cloudy conditions (and thereafter low insolation), short-wavelength radiation becomes predominant.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 1987 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0196-8904(87)90054-9&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 1987 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0196-8904(87)90054-9&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Authors:Gopinath Halder;
Gopinath Halder
Gopinath Halder in OpenAIREBisheswar Karmakar;
Bisheswar Karmakar
Bisheswar Karmakar in OpenAIREAbstract Biodiesel has gained the forefront of our focus on renewable transportation fuels. This article provides a comprehensive review on the sources used as feedstock and their classification based on generation or type (edible, non-edible, waste resources and animal fats) along with a variety of classical and modern oil extraction techniques. The technical aspects of the various biodiesel production methods currently implemented to the best of our knowledge are discussed here, which include in-situ biodiesel production, both catalysed (homogeneous and heterogeneous systems) and uncatalysed classical production approaches, with emphasis on how each of these approaches are affected by their reaction parameters. The review also highlights the observed drawbacks of each process with a view to assessing the implementation of supercritical and superheated technologies as an alternative, economically feasible advancement. Supercritical process (SCP) has shown great prospect in the obtainment of high quality biodiesel from a wide range of high to low grade feedstock with minimal impacts on the presence of water or FFAs (free fatty acids). From available literature it is shown that these do not affect the process significantly, and various other supercritical fluids such as methyl acetate, tert-butyl methyl ether (MTBE) and dimethyl carbonate can also be used to avoid glycerol formation. The process however, suffers from high initial implementation cost being the most prominent drawback, among others like thermal degradation of the fuel. Another promising technique, the superheated vapour technology (SHV) has emerged as an alternative, with limited literature proving the superiority of either of these processes to be inconclusive. In future works, researchers need to look into various aspects such as developing a spiral reactor for heat recovery, using software based optimization for eliminating redundant experiments analysing production cost for industrial scale-up and improving the fuel’s oxidative stability by adding antioxidants for convenient long-term storage and use.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2019 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.12.066&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 182 citations 182 popularity Top 1% influence Top 10% impulse Top 0.1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2019 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.12.066&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1996Publisher:Elsevier BV Authors: C.L. Leci;Abstract Four power generation options covering the spectrum of methods of fossil fuel power generation were used as the base cases to determine the resultant increase in base case levelized generating costs resulting from CO2 capture from the flue gas of a 500 MWc power station by liquid scrubbing technology. Suitable liquid scrubbing technology for CO2 capture was investigated only for end of pipe treatment, after upstream FGD (where applicable), for each of the options of a 500 MWe power station from coal and natural gas at a coastal site in the Netherlands. The three coal options were based on pulverised fuel, IGCC, and coal combustion in a mixture of oxygen and recycle gas respectively, whilst the natural gas option was based on a sulphur free NGCC. Only commercially proven liquid scrubbing technology screened in economic and technical terms. Inhibited MEA (monoethanolamine) was the most acceptable for the conventional pulverised coal fired power station, the IGCC coal fired power station and the NGCC plant. Selexol® was the most suitable for combustion of coal in the recycle mixture. In all cases pre treatment was necessary to remove traces of NOx and/or SO2 which otherwise would cause solvent degradation. As a consequence of CO2 capture, drastic reductions of both acid gases and particulates occur. The reduction in overall generating efficiency over the four options ranged from 2.4 to 13.5 per cent corresponding to an increase in power station nameplate capacity of 540 to 740 MWe to achieve a net export of 500 MWe after CO2 capture and regeneration. Investment costs increased substantially by between 52 to 108 per cent in terms of $/kWso. Over the range of options the resultant levalised base case generating costs increased from 22 to 108 per cent. The conventional PF coal power station showed an increase from 53.4 to 80.38 mills/kWhso and the natural gas (sulphur free) NGCC plant showed an increase from 32 to 50.24 mills/kWhso. In the case of the non conventional combustion of coal in recycle gas the cost increased from 83 to 101 mills/kWhso. Because the base case selected for the coal based IGCC plant required CO2 to be captured at almost atmospheric conditions, rather than at higher pressure, the costs were seriously distorted and are not readily comparable with the other options. The nett parasitic effect was not only to substantially increase investment costs but also to substantially increase the basic cost of electricity irrespective of the type of fuel and method of power generation. The balance between a CO2 tax and CO2 capture cannot be inferred without taking into cognisance the additional cost of CO2 disposal.
Fuel and Energy Abst... arrow_drop_down Fuel and Energy AbstractsArticle . 1996 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefEnergy Conversion and ManagementArticle . 1996 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0140-6701(96)88936-3&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu31 citations 31 popularity Top 10% influence Top 1% impulse Average Powered by BIP!
more_vert Fuel and Energy Abst... arrow_drop_down Fuel and Energy AbstractsArticle . 1996 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefEnergy Conversion and ManagementArticle . 1996 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0140-6701(96)88936-3&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Authors: José Sigefredo Pinheiro Neto; Paulo Cesar Marques de Carvalho;Ivonne Montero Dupont;
Ivonne Montero Dupont
Ivonne Montero Dupont in OpenAIRESandro César Silveira Jucá;
Sandro César Silveira Jucá
Sandro César Silveira Jucá in OpenAIREAbstract The use of photovoltaic solar power generation is rising as worldwide energy demand increases. Therefore, reliability, safety, life cycle, and improved efficiency of photovoltaic plants have all become a major concern in research nowadays. In this context, monitoring systems are necessary to guarantee the required operating productivity and to avoid overpriced maintenance costs. This paper studies the non-ideal operating conditions for grid-connected photovoltaic plants and proposes an anomaly detection methodology that combines the advantages of the 2-sigma, short-window simple-moving average control charts with shading strength and irradiance transition parameters to detect early deviation in photovoltaic plant operational data. The key aspect of proposed methodology is that it requires neither historical data for model training procedure nor parameters from previous simulation. Only instantaneous meteorological and electrical parameters are required. The efficiency of the condition monitoring methodology has been validated through experimental results conducted in actual operating conditions. Results demonstrated that the proposed methodology is effective to identify non-ideal operating conditions for grid-connected photovoltaic plants, i.e., (i) normal operating condition, (ii) natural dynamic shading, (iii) artificial dynamic shading, and (iv) artificial static shading. Moreover, a low-cost and non-invasive internet-of-things-based embedded architecture is proposed to monitor photovoltaic plant operation in real-time.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2019 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2019.112078&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 23 citations 23 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2019 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2019.112078&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1984Publisher:Elsevier BV Authors: Tariq Muneer; M.M. Hawas;Abstract The relative merits of a thermosyphon heater for domestic water heating are brought to light with special emphasis to Libyan weather conditions. The experimental performance of this type of heater was studied by the authors for a brief period and reported in an earlier study. In the present study, year-round experimental performance is reported. Measurements performed all over the year showed that water is heated to a maximum temperature of 66°C while the minimum temperature during six months was as high as 50°C. The picture is no less bright from an overall efficiency point of view. Efficiency ranges as high as 40 to 50%. Hourly measurements on various days showed that the water temperature has an increasing trend, irrespective of the fluctuating solar radiation pattern on a cloudy day.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 1984 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0196-8904(84)90041-4&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 6 citations 6 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 1984 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0196-8904(84)90041-4&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016Publisher:Elsevier BV Authors: Hojat Ghassemi; Amir Labbafan;Abstract In this paper, a three-dimensional numerical simulation was carried out to characterize a high-ash coal gasification in a pressurized, oxygen-blown, two-stage E-Gas entrained flow gasifier. The Tabas coal was used as a high-ash feedstock, with 32 wt% ash and was compared with the Illinois #6 low-ash coal, with 10 wt% ash. The computational model was conducted in ANSYS FLUENT 14 based on the conservation equations described in the Eulerian–Lagrangian approach. Also, four heterogeneous combined with seven homogeneous reactions were solved via the finite rate and eddy-dissipation/finite rate model, respectively. Two different parametric analyses were conducted to characterize the gasification process in the E-Gas gasifier. These analyses cover the effects of the O2/Coal ratio and coal slurry water content on the gasifier performance characteristics such as the exit temperature, main species mole fractions, carbon conversion, high heating value, yield syngas fraction and cold gas efficiency. It was found that using the higher ash content coal decreases the cold gas efficiency about 5%, limits the gasifier economical operating range, and reduces the exit temperature, yield syngas and total higher heating value.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2016.01.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 37 citations 37 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2016.01.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014Publisher:Elsevier BV Authors: Jingping Liu; Zheng Chen; Chia-Fon Lee; Zhenkuo Wu;Abstract In this work, the combustion and emission fundamentals of high n-butanol/diesel ratio blend with 40% butanol (i.e., Bu40) in a heavy-duty diesel engine were investigated by experiment and simulation at constant engine speed of 1400 rpm and an IMEP of 1.0 MPa. Additionally, the impact of EGR was evaluated experimentally and compared with neat diesel fuel (i.e., Bu00). The results show that Bu40 has higher cylinder pressure, longer ignition delay, and faster burning rate than Bu00. Compared with Bu00, moreover, Bu40 has higher NOx due to wider combustion high-temperature region, lower soot due to local lower equivalence ratio distribution, and higher CO due to lower gas temperature in the late expansion process. For Bu40, EGR reduces NOx emissions dramatically with no obvious influence on soot. Meanwhile, there is no significant change in HC and CO emissions and indicated thermal efficiency (ITE) with EGR until EGR threshold is reached. When EGR rate exceeds the threshold level, HC and CO emissions increase dramatically, and ITE decreases markedly. Compared with Bu00, the threshold of Bu40 appears at lower EGR rate. Consequently, combining high butanol/diesel ratio blend with medium EGR has the potential to achieve ultra-low NOx and soot emissions simultaneously while maintaining high thermal efficiency level.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2014 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2013.11.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 236 citations 236 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2014 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2013.11.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu