description Publicationkeyboard_double_arrow_right Article , Journal 2019 AustraliaPublisher:Elsevier BV Authors: Fan Zhang; Richard de Dear; Peter Hancock;handle: 10072/381697
Abstract The effect of the thermal environment on performance and productivity has been a focus of interest among indoor environmental researchers for nearly a century, but most of that work has been conducted in relative isolation from the cognate disciplines of human performance evaluation. The present review examines thermal environmental effects on cognitive performance research conducted across multiple disciplines. After differentiating performance from productivity, we compare the two dominant conceptual models linking thermal stress to performance; (1) the inverted-U concept and (2) the extended-U relationship. The inverted-U specifies a single optimum temperature (or its corresponding subjective thermal sensation) at which performance is maximised. In contrast, the extended-U model posits a broad central plateau across which there is no discernible thermal effect on cognitive performance. This performance plateau is bounded by regions of progressive performance decrements in more extreme thermal conditions. The contradictions between these opposing conceptual models might derive from various confounding factors at play in their underlying research bases. These include, inter alia, environment-related, task-related, and performer-related factors, as well as their associated two-way and three-way interaction effects. Methodological discrepancies that might also contribute to the divergence of these conceptual models are evaluated, along with the proposed causal mechanisms underlying the two models. The weight of research evidence reviewed in this paper suggests that the extended-U hypothesis fits the relationship between moderate thermal environments and cognitive performance. In contrast to the inverted-U relationship, implemention of the extended-U in indoor climate control implies substantial reductions in building energy demand, since it permits the heating and cooling setpoint deadband to expand across the full width of the thermal comfort zone, or even slightly further during emergencies such as peak demand events on the electricity grid. Use of personal comfort systems can further extend the thermostat setpoint range beyond the comfort zone.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 149 citations 149 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 AustraliaPublisher:Elsevier BV Authors: Fan Zhang; Richard de Dear; Peter Hancock;handle: 10072/381697
Abstract The effect of the thermal environment on performance and productivity has been a focus of interest among indoor environmental researchers for nearly a century, but most of that work has been conducted in relative isolation from the cognate disciplines of human performance evaluation. The present review examines thermal environmental effects on cognitive performance research conducted across multiple disciplines. After differentiating performance from productivity, we compare the two dominant conceptual models linking thermal stress to performance; (1) the inverted-U concept and (2) the extended-U relationship. The inverted-U specifies a single optimum temperature (or its corresponding subjective thermal sensation) at which performance is maximised. In contrast, the extended-U model posits a broad central plateau across which there is no discernible thermal effect on cognitive performance. This performance plateau is bounded by regions of progressive performance decrements in more extreme thermal conditions. The contradictions between these opposing conceptual models might derive from various confounding factors at play in their underlying research bases. These include, inter alia, environment-related, task-related, and performer-related factors, as well as their associated two-way and three-way interaction effects. Methodological discrepancies that might also contribute to the divergence of these conceptual models are evaluated, along with the proposed causal mechanisms underlying the two models. The weight of research evidence reviewed in this paper suggests that the extended-U hypothesis fits the relationship between moderate thermal environments and cognitive performance. In contrast to the inverted-U relationship, implemention of the extended-U in indoor climate control implies substantial reductions in building energy demand, since it permits the heating and cooling setpoint deadband to expand across the full width of the thermal comfort zone, or even slightly further during emergencies such as peak demand events on the electricity grid. Use of personal comfort systems can further extend the thermostat setpoint range beyond the comfort zone.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 149 citations 149 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024 ItalyPublisher:Elsevier BV Toja, F; Perlini, L; Facchi, D; Casalegno, A; Zago, M;handle: 11311/1258913
Electrolyte imbalance caused by the undesired vanadium-ions cross-over and water transport through the membrane is one of the main critical issues of vanadium redox flow batteries, leading to battery capacity loss and electrolytes volume variation. In this work, the evolution of discharged capacity and electrolyte volume variation were firstly investigated adopting commercial electrolyte for hundreds of charge-discharge cycles in vanadium redox flow batteries employing different membranes, varying thickness and equivalent weight. Subsequently, with the support of a 1D physics-based model, the origin of the main phenomena regulating capacity decay and volume variation has been identified and different modifications in the preparation of electrolytes have been proposed. Electrolytes characterized by an equal proton concentration between the two tanks at the beginning of cycling operation turned out to limit capacity decay, while increasing electrolyte proton concentration was effective also in the mitigation of volume variation. The most promising electrolyte preparation combined the effect of high proton concentration and null osmotic pressure gradient between the two tanks: compared to commercial electrolyte this preparation reduced the capacity decay from 47.7% to 20.9%, increased the coulombic efficiency from 96.2% to 98.9% and the energy one from 79.9% to 83.4%, and also implied a negligible volume variation during cycles. The effectiveness of this electrolyte preparation has been verified with different membranes, increasing the range of validity of the results, that could be thus applied in a real system regardless of the adopted membrane.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 8 citations 8 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024 ItalyPublisher:Elsevier BV Toja, F; Perlini, L; Facchi, D; Casalegno, A; Zago, M;handle: 11311/1258913
Electrolyte imbalance caused by the undesired vanadium-ions cross-over and water transport through the membrane is one of the main critical issues of vanadium redox flow batteries, leading to battery capacity loss and electrolytes volume variation. In this work, the evolution of discharged capacity and electrolyte volume variation were firstly investigated adopting commercial electrolyte for hundreds of charge-discharge cycles in vanadium redox flow batteries employing different membranes, varying thickness and equivalent weight. Subsequently, with the support of a 1D physics-based model, the origin of the main phenomena regulating capacity decay and volume variation has been identified and different modifications in the preparation of electrolytes have been proposed. Electrolytes characterized by an equal proton concentration between the two tanks at the beginning of cycling operation turned out to limit capacity decay, while increasing electrolyte proton concentration was effective also in the mitigation of volume variation. The most promising electrolyte preparation combined the effect of high proton concentration and null osmotic pressure gradient between the two tanks: compared to commercial electrolyte this preparation reduced the capacity decay from 47.7% to 20.9%, increased the coulombic efficiency from 96.2% to 98.9% and the energy one from 79.9% to 83.4%, and also implied a negligible volume variation during cycles. The effectiveness of this electrolyte preparation has been verified with different membranes, increasing the range of validity of the results, that could be thus applied in a real system regardless of the adopted membrane.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 8 citations 8 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016Publisher:Elsevier BV Authors: Tingting Liu; Zhengang Liu; Nana Peng; Chao Gai;Abstract Hydrothermal treatment (HT) is one of the efficient approaches for upgrading municipal solid waste (MSW). In the present study, emission characteristics of polycyclic aromatic hydrocarbons (PAHs) from hydrothermally treated municipal solid waste (H-MSW) combustion alone and H-MSW/coal co-combustion were investigated at different temperatures. The results showed that for all fuel combustion, the majority of PAHs were 3- or 4-ring PAHs. In addition, flue gas had the highest yields of PAHs followed by fly ash and bottom ash, while the ring number of dominated PAHs in fly ash was higher than those in flue gas and bottom ash. Compared to MSW, H-MSW combustion generated less PAHs at the value of 1131.95–7649.24 μg/g. The blending of H-MSW and coal reduced total PAH emissions and positive interactions were observed between H-MSW and coal during co-combustion. The toxicity equivalent quantity (TEQ) values of the PAHs from combustion were in the order MSW > H-MSW > H-MSW/coal, which was consistent with the total PAH emissions. The present study illustrated that significant reduction of PAH emissions and toxicity from combustion could be achieved by HT and the blending of H-MSW and coal.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 36 citations 36 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016Publisher:Elsevier BV Authors: Tingting Liu; Zhengang Liu; Nana Peng; Chao Gai;Abstract Hydrothermal treatment (HT) is one of the efficient approaches for upgrading municipal solid waste (MSW). In the present study, emission characteristics of polycyclic aromatic hydrocarbons (PAHs) from hydrothermally treated municipal solid waste (H-MSW) combustion alone and H-MSW/coal co-combustion were investigated at different temperatures. The results showed that for all fuel combustion, the majority of PAHs were 3- or 4-ring PAHs. In addition, flue gas had the highest yields of PAHs followed by fly ash and bottom ash, while the ring number of dominated PAHs in fly ash was higher than those in flue gas and bottom ash. Compared to MSW, H-MSW combustion generated less PAHs at the value of 1131.95–7649.24 μg/g. The blending of H-MSW and coal reduced total PAH emissions and positive interactions were observed between H-MSW and coal during co-combustion. The toxicity equivalent quantity (TEQ) values of the PAHs from combustion were in the order MSW > H-MSW > H-MSW/coal, which was consistent with the total PAH emissions. The present study illustrated that significant reduction of PAH emissions and toxicity from combustion could be achieved by HT and the blending of H-MSW and coal.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 36 citations 36 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 United KingdomPublisher:Elsevier BV Authors: Janet F. Barlow; Phil Coker; M. L. Kubik;Thermal generation is a vital component of mature and reliable electricity markets. As the share of renewable electricity in such markets grows, so too do the challenges associated with its variability. Proposed solutions to these challenges typically focus on alternatives to primary generation, such as energy storage, demand side management, or increased interconnection. Less attention is given to the demands placed on conventional thermal generation or its potential for increased flexibility. However, for the foreseeable future, conventional plants will have to operate alongside new renewables and have an essential role in accommodating increasing supply-side variability.\ud \ud This paper explores the role that conventional generation has to play in managing variability through the sub-system case study of Northern Ireland, identifying the significance of specific plant characteristics for reliable system operation. Particular attention is given to the challenges of wind ramping and the need to avoid excessive wind curtailment. Potential for conflict is identified with the role for conventional plant in addressing these two challenges. Market specific strategies for using the existing fleet of generation to reduce the impact of renewable resource variability are proposed, and wider lessons from the approach taken are identified.
CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 105 citations 105 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 United KingdomPublisher:Elsevier BV Authors: Janet F. Barlow; Phil Coker; M. L. Kubik;Thermal generation is a vital component of mature and reliable electricity markets. As the share of renewable electricity in such markets grows, so too do the challenges associated with its variability. Proposed solutions to these challenges typically focus on alternatives to primary generation, such as energy storage, demand side management, or increased interconnection. Less attention is given to the demands placed on conventional thermal generation or its potential for increased flexibility. However, for the foreseeable future, conventional plants will have to operate alongside new renewables and have an essential role in accommodating increasing supply-side variability.\ud \ud This paper explores the role that conventional generation has to play in managing variability through the sub-system case study of Northern Ireland, identifying the significance of specific plant characteristics for reliable system operation. Particular attention is given to the challenges of wind ramping and the need to avoid excessive wind curtailment. Potential for conflict is identified with the role for conventional plant in addressing these two challenges. Market specific strategies for using the existing fleet of generation to reduce the impact of renewable resource variability are proposed, and wider lessons from the approach taken are identified.
CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 105 citations 105 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint 2024Embargo end date: 01 Jan 2022Publisher:Elsevier BV Authors: De Mel, Ishanki; Klymenko, Oleksiy V.; Short, Michael;The optimal selection, sizing, and location of small-scale technologies within a grid-connected distributed energy system (DES) can contribute to reducing carbon emissions, consumer costs, and network imbalances. This is the first study to present an optimisation framework for obtaining discrete technology sizing and selection for grid-connected DES design, while simultaneously considering multiphase optimal power flow (MOPF) constraints to accurately represent unbalanced low-voltage distribution networks. An algorithm is developed to solve the resulting Mixed-Integer Nonlinear Programming (MINLP) formulation. It employs a decomposition based on Mixed-Integer Linear Programming (MILP) and Nonlinear Programming (NLP), and utilises integer cuts and complementarity reformulations to obtain discrete designs that are also feasible with respect to the network constraints. A heuristic modification to the original algorithm is also proposed to improve computational speed. Improved formulations for selecting feasible combinations of air source heat pumps (ASHPs) and hot water storage tanks are also presented. The algorithms outperform the existing state-of-the-art commercial MINLP solver, which fails to find any solutions in two instances. While feasible solutions were obtained for all cases, convergence was not achieved for all, especially for those involving the larger network. Where converged, the algorithm with the heuristic modification has achieved results up to 70% faster than the original algorithm. Results for case studies suggest that including ASHPs can support up to 16% higher renewable generation capacity compared to gas boilers, albeit with higher ASHP investment costs. The optimisation framework and results can be used to inform stakeholders such as policy-makers and network operators, to increase renewable energy capacity and aid the decarbonisation of domestic heating systems. 47 pages, 10 figures, 14 Tables
Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 6 citations 6 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint 2024Embargo end date: 01 Jan 2022Publisher:Elsevier BV Authors: De Mel, Ishanki; Klymenko, Oleksiy V.; Short, Michael;The optimal selection, sizing, and location of small-scale technologies within a grid-connected distributed energy system (DES) can contribute to reducing carbon emissions, consumer costs, and network imbalances. This is the first study to present an optimisation framework for obtaining discrete technology sizing and selection for grid-connected DES design, while simultaneously considering multiphase optimal power flow (MOPF) constraints to accurately represent unbalanced low-voltage distribution networks. An algorithm is developed to solve the resulting Mixed-Integer Nonlinear Programming (MINLP) formulation. It employs a decomposition based on Mixed-Integer Linear Programming (MILP) and Nonlinear Programming (NLP), and utilises integer cuts and complementarity reformulations to obtain discrete designs that are also feasible with respect to the network constraints. A heuristic modification to the original algorithm is also proposed to improve computational speed. Improved formulations for selecting feasible combinations of air source heat pumps (ASHPs) and hot water storage tanks are also presented. The algorithms outperform the existing state-of-the-art commercial MINLP solver, which fails to find any solutions in two instances. While feasible solutions were obtained for all cases, convergence was not achieved for all, especially for those involving the larger network. Where converged, the algorithm with the heuristic modification has achieved results up to 70% faster than the original algorithm. Results for case studies suggest that including ASHPs can support up to 16% higher renewable generation capacity compared to gas boilers, albeit with higher ASHP investment costs. The optimisation framework and results can be used to inform stakeholders such as policy-makers and network operators, to increase renewable energy capacity and aid the decarbonisation of domestic heating systems. 47 pages, 10 figures, 14 Tables
Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 6 citations 6 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV Edoardo Bertone; Oz Sahin; Rodney A. Stewart; Patrick X.W. Zou; Morshed Alam; Keith Hampson; Evan Blair;handle: 20.500.11937/61841 , 1959.3/440423 , 10072/379867
Abstract In Australia, the government spending on public buildings’ energy and water consumption is considerable; however the building energy and water retrofit market potential has been diminished by a number of barriers, especially financial. In contrast, in other advanced economies there are several reported financing strategies that have been shown to accelerate retrofit projects implementation. In this study, a coupled Bayesian Network – System Dynamics model was developed with the core aim to assess the likely influence of those novel financing options and procurement procedures on public building retrofit outcomes scenarios in the Australian context. A particular case-study focusing on Australian public hospitals was showcased as an example in this paper. Stakeholder engagement was utilised to estimate likely preferences and to conceptualise causal relationships of model parameters. The scenario modelling showed that a revolving loan fund supporting an energy performance contracting procurement procedure was preferred. Subsequently, the specific features of this preferred framework were optimised to yield the greatest number of viable retrofit projects over the long term. The results indicated that such a financing scheme would lead to substantial abatement of energy and water consumption, as well as carbon emissions. The strategic scenario analysis approach developed herein provides evidence-based support to policy-makers advocating novel financing and procurement models for addressing a government’s sustainability agenda in a financially responsible and net-positive manner.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 70 citations 70 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV Edoardo Bertone; Oz Sahin; Rodney A. Stewart; Patrick X.W. Zou; Morshed Alam; Keith Hampson; Evan Blair;handle: 20.500.11937/61841 , 1959.3/440423 , 10072/379867
Abstract In Australia, the government spending on public buildings’ energy and water consumption is considerable; however the building energy and water retrofit market potential has been diminished by a number of barriers, especially financial. In contrast, in other advanced economies there are several reported financing strategies that have been shown to accelerate retrofit projects implementation. In this study, a coupled Bayesian Network – System Dynamics model was developed with the core aim to assess the likely influence of those novel financing options and procurement procedures on public building retrofit outcomes scenarios in the Australian context. A particular case-study focusing on Australian public hospitals was showcased as an example in this paper. Stakeholder engagement was utilised to estimate likely preferences and to conceptualise causal relationships of model parameters. The scenario modelling showed that a revolving loan fund supporting an energy performance contracting procurement procedure was preferred. Subsequently, the specific features of this preferred framework were optimised to yield the greatest number of viable retrofit projects over the long term. The results indicated that such a financing scheme would lead to substantial abatement of energy and water consumption, as well as carbon emissions. The strategic scenario analysis approach developed herein provides evidence-based support to policy-makers advocating novel financing and procurement models for addressing a government’s sustainability agenda in a financially responsible and net-positive manner.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 70 citations 70 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 FrancePublisher:Elsevier BV Rachid Outbib; Daniel Hissel; Daniel Hissel; Stefan Giurgea; Stefan Giurgea; Yongdong Li; Zhongliang Li; Zhongliang Li;This paper proposes a data-driven diagnostic approach for Polymer Electrolyte Membrane Fuel Cell (PEMFC) systems. Fault detection and isolation (FDI) is realized by analyzing individual cell voltages. A feature extraction method Fisher Discriminant Analysis (FDA) and a multi-class classification method Directed Acyclic Graph Support Vector Machine (DAGSVM) are utilized successively to extract the useful features from raw data and classify the extracted features into various classes related to health states. Experimental data of two different stacks are used to validate the proposed approach. The results show that five concerned faults can be detected and isolated with a high accuracy. Moreover, the light computational cost of the approach enhances the possibility of its online implementation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu57 citations 57 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 FrancePublisher:Elsevier BV Rachid Outbib; Daniel Hissel; Daniel Hissel; Stefan Giurgea; Stefan Giurgea; Yongdong Li; Zhongliang Li; Zhongliang Li;This paper proposes a data-driven diagnostic approach for Polymer Electrolyte Membrane Fuel Cell (PEMFC) systems. Fault detection and isolation (FDI) is realized by analyzing individual cell voltages. A feature extraction method Fisher Discriminant Analysis (FDA) and a multi-class classification method Directed Acyclic Graph Support Vector Machine (DAGSVM) are utilized successively to extract the useful features from raw data and classify the extracted features into various classes related to health states. Experimental data of two different stacks are used to validate the proposed approach. The results show that five concerned faults can be detected and isolated with a high accuracy. Moreover, the light computational cost of the approach enhances the possibility of its online implementation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu57 citations 57 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Authors: Kevin J. Kircher; K. Max Zhang;Abstract Efficient electric heat pumps have the potential to significantly reduce greenhouse gas emissions from heating and cooling buildings. However, heat pumps’ initial costs can be prohibitively high and their lifetime costs are only situationally competitive with incumbent technologies. Here we show that a business model based on heat purchase agreements could lower these barriers to heat pump adoption. In this business model, a user hosts a heat pump owned by an aggregator. The aggregator installs the heat pump at low or no initial cost to the user. The user buys the heat pump’s heat or cooling output from the aggregator. The aggregator buys the heat pump’s input electricity in the wholesale energy market and sells the flexibility of their aggregate electrical load in ancillary service markets. This paper presents the first economic analysis of heat purchase agreements as a third-party ownership model for electric heat pumps. We derive conditions under which a heat purchase agreement is mutually beneficial to the user and the aggregator. We also provide a method to fairly price heat and cooling. A case study of a typical United States home shows that a heat purchase agreement could more than double the value of a heat pump investment relative to the incumbent business model. The potential impact of this work is to reduce emissions both directly, by accelerating replacement of fossil-fueled or inefficient heating or cooling equipment, and indirectly, by helping power system operators reliably integrate wind and solar generation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 18 citations 18 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Authors: Kevin J. Kircher; K. Max Zhang;Abstract Efficient electric heat pumps have the potential to significantly reduce greenhouse gas emissions from heating and cooling buildings. However, heat pumps’ initial costs can be prohibitively high and their lifetime costs are only situationally competitive with incumbent technologies. Here we show that a business model based on heat purchase agreements could lower these barriers to heat pump adoption. In this business model, a user hosts a heat pump owned by an aggregator. The aggregator installs the heat pump at low or no initial cost to the user. The user buys the heat pump’s heat or cooling output from the aggregator. The aggregator buys the heat pump’s input electricity in the wholesale energy market and sells the flexibility of their aggregate electrical load in ancillary service markets. This paper presents the first economic analysis of heat purchase agreements as a third-party ownership model for electric heat pumps. We derive conditions under which a heat purchase agreement is mutually beneficial to the user and the aggregator. We also provide a method to fairly price heat and cooling. A case study of a typical United States home shows that a heat purchase agreement could more than double the value of a heat pump investment relative to the incumbent business model. The potential impact of this work is to reduce emissions both directly, by accelerating replacement of fossil-fueled or inefficient heating or cooling equipment, and indirectly, by helping power system operators reliably integrate wind and solar generation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 18 citations 18 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2025 GermanyPublisher:Elsevier BV Fabian Wüllhorst; Sebastian Schwarz; Nico Fuchs; Laura Maier; Antonello Monti; Dirk Müller;Applied energy 388, 125530 (2025). doi:10.1016/j.apenergy.2025.125530 Published by Elsevier Science, Amsterdam [u.a.]
Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2025 GermanyPublisher:Elsevier BV Fabian Wüllhorst; Sebastian Schwarz; Nico Fuchs; Laura Maier; Antonello Monti; Dirk Müller;Applied energy 388, 125530 (2025). doi:10.1016/j.apenergy.2025.125530 Published by Elsevier Science, Amsterdam [u.a.]
Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2019 AustraliaPublisher:Elsevier BV Authors: Fan Zhang; Richard de Dear; Peter Hancock;handle: 10072/381697
Abstract The effect of the thermal environment on performance and productivity has been a focus of interest among indoor environmental researchers for nearly a century, but most of that work has been conducted in relative isolation from the cognate disciplines of human performance evaluation. The present review examines thermal environmental effects on cognitive performance research conducted across multiple disciplines. After differentiating performance from productivity, we compare the two dominant conceptual models linking thermal stress to performance; (1) the inverted-U concept and (2) the extended-U relationship. The inverted-U specifies a single optimum temperature (or its corresponding subjective thermal sensation) at which performance is maximised. In contrast, the extended-U model posits a broad central plateau across which there is no discernible thermal effect on cognitive performance. This performance plateau is bounded by regions of progressive performance decrements in more extreme thermal conditions. The contradictions between these opposing conceptual models might derive from various confounding factors at play in their underlying research bases. These include, inter alia, environment-related, task-related, and performer-related factors, as well as their associated two-way and three-way interaction effects. Methodological discrepancies that might also contribute to the divergence of these conceptual models are evaluated, along with the proposed causal mechanisms underlying the two models. The weight of research evidence reviewed in this paper suggests that the extended-U hypothesis fits the relationship between moderate thermal environments and cognitive performance. In contrast to the inverted-U relationship, implemention of the extended-U in indoor climate control implies substantial reductions in building energy demand, since it permits the heating and cooling setpoint deadband to expand across the full width of the thermal comfort zone, or even slightly further during emergencies such as peak demand events on the electricity grid. Use of personal comfort systems can further extend the thermostat setpoint range beyond the comfort zone.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 149 citations 149 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 AustraliaPublisher:Elsevier BV Authors: Fan Zhang; Richard de Dear; Peter Hancock;handle: 10072/381697
Abstract The effect of the thermal environment on performance and productivity has been a focus of interest among indoor environmental researchers for nearly a century, but most of that work has been conducted in relative isolation from the cognate disciplines of human performance evaluation. The present review examines thermal environmental effects on cognitive performance research conducted across multiple disciplines. After differentiating performance from productivity, we compare the two dominant conceptual models linking thermal stress to performance; (1) the inverted-U concept and (2) the extended-U relationship. The inverted-U specifies a single optimum temperature (or its corresponding subjective thermal sensation) at which performance is maximised. In contrast, the extended-U model posits a broad central plateau across which there is no discernible thermal effect on cognitive performance. This performance plateau is bounded by regions of progressive performance decrements in more extreme thermal conditions. The contradictions between these opposing conceptual models might derive from various confounding factors at play in their underlying research bases. These include, inter alia, environment-related, task-related, and performer-related factors, as well as their associated two-way and three-way interaction effects. Methodological discrepancies that might also contribute to the divergence of these conceptual models are evaluated, along with the proposed causal mechanisms underlying the two models. The weight of research evidence reviewed in this paper suggests that the extended-U hypothesis fits the relationship between moderate thermal environments and cognitive performance. In contrast to the inverted-U relationship, implemention of the extended-U in indoor climate control implies substantial reductions in building energy demand, since it permits the heating and cooling setpoint deadband to expand across the full width of the thermal comfort zone, or even slightly further during emergencies such as peak demand events on the electricity grid. Use of personal comfort systems can further extend the thermostat setpoint range beyond the comfort zone.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 149 citations 149 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2019License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/381697Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.12.005&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024 ItalyPublisher:Elsevier BV Toja, F; Perlini, L; Facchi, D; Casalegno, A; Zago, M;handle: 11311/1258913
Electrolyte imbalance caused by the undesired vanadium-ions cross-over and water transport through the membrane is one of the main critical issues of vanadium redox flow batteries, leading to battery capacity loss and electrolytes volume variation. In this work, the evolution of discharged capacity and electrolyte volume variation were firstly investigated adopting commercial electrolyte for hundreds of charge-discharge cycles in vanadium redox flow batteries employing different membranes, varying thickness and equivalent weight. Subsequently, with the support of a 1D physics-based model, the origin of the main phenomena regulating capacity decay and volume variation has been identified and different modifications in the preparation of electrolytes have been proposed. Electrolytes characterized by an equal proton concentration between the two tanks at the beginning of cycling operation turned out to limit capacity decay, while increasing electrolyte proton concentration was effective also in the mitigation of volume variation. The most promising electrolyte preparation combined the effect of high proton concentration and null osmotic pressure gradient between the two tanks: compared to commercial electrolyte this preparation reduced the capacity decay from 47.7% to 20.9%, increased the coulombic efficiency from 96.2% to 98.9% and the energy one from 79.9% to 83.4%, and also implied a negligible volume variation during cycles. The effectiveness of this electrolyte preparation has been verified with different membranes, increasing the range of validity of the results, that could be thus applied in a real system regardless of the adopted membrane.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 8 citations 8 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024 ItalyPublisher:Elsevier BV Toja, F; Perlini, L; Facchi, D; Casalegno, A; Zago, M;handle: 11311/1258913
Electrolyte imbalance caused by the undesired vanadium-ions cross-over and water transport through the membrane is one of the main critical issues of vanadium redox flow batteries, leading to battery capacity loss and electrolytes volume variation. In this work, the evolution of discharged capacity and electrolyte volume variation were firstly investigated adopting commercial electrolyte for hundreds of charge-discharge cycles in vanadium redox flow batteries employing different membranes, varying thickness and equivalent weight. Subsequently, with the support of a 1D physics-based model, the origin of the main phenomena regulating capacity decay and volume variation has been identified and different modifications in the preparation of electrolytes have been proposed. Electrolytes characterized by an equal proton concentration between the two tanks at the beginning of cycling operation turned out to limit capacity decay, while increasing electrolyte proton concentration was effective also in the mitigation of volume variation. The most promising electrolyte preparation combined the effect of high proton concentration and null osmotic pressure gradient between the two tanks: compared to commercial electrolyte this preparation reduced the capacity decay from 47.7% to 20.9%, increased the coulombic efficiency from 96.2% to 98.9% and the energy one from 79.9% to 83.4%, and also implied a negligible volume variation during cycles. The effectiveness of this electrolyte preparation has been verified with different membranes, increasing the range of validity of the results, that could be thus applied in a real system regardless of the adopted membrane.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 8 citations 8 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122262&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016Publisher:Elsevier BV Authors: Tingting Liu; Zhengang Liu; Nana Peng; Chao Gai;Abstract Hydrothermal treatment (HT) is one of the efficient approaches for upgrading municipal solid waste (MSW). In the present study, emission characteristics of polycyclic aromatic hydrocarbons (PAHs) from hydrothermally treated municipal solid waste (H-MSW) combustion alone and H-MSW/coal co-combustion were investigated at different temperatures. The results showed that for all fuel combustion, the majority of PAHs were 3- or 4-ring PAHs. In addition, flue gas had the highest yields of PAHs followed by fly ash and bottom ash, while the ring number of dominated PAHs in fly ash was higher than those in flue gas and bottom ash. Compared to MSW, H-MSW combustion generated less PAHs at the value of 1131.95–7649.24 μg/g. The blending of H-MSW and coal reduced total PAH emissions and positive interactions were observed between H-MSW and coal during co-combustion. The toxicity equivalent quantity (TEQ) values of the PAHs from combustion were in the order MSW > H-MSW > H-MSW/coal, which was consistent with the total PAH emissions. The present study illustrated that significant reduction of PAH emissions and toxicity from combustion could be achieved by HT and the blending of H-MSW and coal.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 36 citations 36 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016Publisher:Elsevier BV Authors: Tingting Liu; Zhengang Liu; Nana Peng; Chao Gai;Abstract Hydrothermal treatment (HT) is one of the efficient approaches for upgrading municipal solid waste (MSW). In the present study, emission characteristics of polycyclic aromatic hydrocarbons (PAHs) from hydrothermally treated municipal solid waste (H-MSW) combustion alone and H-MSW/coal co-combustion were investigated at different temperatures. The results showed that for all fuel combustion, the majority of PAHs were 3- or 4-ring PAHs. In addition, flue gas had the highest yields of PAHs followed by fly ash and bottom ash, while the ring number of dominated PAHs in fly ash was higher than those in flue gas and bottom ash. Compared to MSW, H-MSW combustion generated less PAHs at the value of 1131.95–7649.24 μg/g. The blending of H-MSW and coal reduced total PAH emissions and positive interactions were observed between H-MSW and coal during co-combustion. The toxicity equivalent quantity (TEQ) values of the PAHs from combustion were in the order MSW > H-MSW > H-MSW/coal, which was consistent with the total PAH emissions. The present study illustrated that significant reduction of PAH emissions and toxicity from combustion could be achieved by HT and the blending of H-MSW and coal.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 36 citations 36 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.10.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 United KingdomPublisher:Elsevier BV Authors: Janet F. Barlow; Phil Coker; M. L. Kubik;Thermal generation is a vital component of mature and reliable electricity markets. As the share of renewable electricity in such markets grows, so too do the challenges associated with its variability. Proposed solutions to these challenges typically focus on alternatives to primary generation, such as energy storage, demand side management, or increased interconnection. Less attention is given to the demands placed on conventional thermal generation or its potential for increased flexibility. However, for the foreseeable future, conventional plants will have to operate alongside new renewables and have an essential role in accommodating increasing supply-side variability.\ud \ud This paper explores the role that conventional generation has to play in managing variability through the sub-system case study of Northern Ireland, identifying the significance of specific plant characteristics for reliable system operation. Particular attention is given to the challenges of wind ramping and the need to avoid excessive wind curtailment. Potential for conflict is identified with the role for conventional plant in addressing these two challenges. Market specific strategies for using the existing fleet of generation to reduce the impact of renewable resource variability are proposed, and wider lessons from the approach taken are identified.
CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 105 citations 105 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 United KingdomPublisher:Elsevier BV Authors: Janet F. Barlow; Phil Coker; M. L. Kubik;Thermal generation is a vital component of mature and reliable electricity markets. As the share of renewable electricity in such markets grows, so too do the challenges associated with its variability. Proposed solutions to these challenges typically focus on alternatives to primary generation, such as energy storage, demand side management, or increased interconnection. Less attention is given to the demands placed on conventional thermal generation or its potential for increased flexibility. However, for the foreseeable future, conventional plants will have to operate alongside new renewables and have an essential role in accommodating increasing supply-side variability.\ud \ud This paper explores the role that conventional generation has to play in managing variability through the sub-system case study of Northern Ireland, identifying the significance of specific plant characteristics for reliable system operation. Particular attention is given to the challenges of wind ramping and the need to avoid excessive wind curtailment. Potential for conflict is identified with the role for conventional plant in addressing these two challenges. Market specific strategies for using the existing fleet of generation to reduce the impact of renewable resource variability are proposed, and wider lessons from the approach taken are identified.
CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 105 citations 105 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert CORE arrow_drop_down Central Archive at the University of ReadingArticle . 2015License: CC BY NC NDData sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.04.063&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint 2024Embargo end date: 01 Jan 2022Publisher:Elsevier BV Authors: De Mel, Ishanki; Klymenko, Oleksiy V.; Short, Michael;The optimal selection, sizing, and location of small-scale technologies within a grid-connected distributed energy system (DES) can contribute to reducing carbon emissions, consumer costs, and network imbalances. This is the first study to present an optimisation framework for obtaining discrete technology sizing and selection for grid-connected DES design, while simultaneously considering multiphase optimal power flow (MOPF) constraints to accurately represent unbalanced low-voltage distribution networks. An algorithm is developed to solve the resulting Mixed-Integer Nonlinear Programming (MINLP) formulation. It employs a decomposition based on Mixed-Integer Linear Programming (MILP) and Nonlinear Programming (NLP), and utilises integer cuts and complementarity reformulations to obtain discrete designs that are also feasible with respect to the network constraints. A heuristic modification to the original algorithm is also proposed to improve computational speed. Improved formulations for selecting feasible combinations of air source heat pumps (ASHPs) and hot water storage tanks are also presented. The algorithms outperform the existing state-of-the-art commercial MINLP solver, which fails to find any solutions in two instances. While feasible solutions were obtained for all cases, convergence was not achieved for all, especially for those involving the larger network. Where converged, the algorithm with the heuristic modification has achieved results up to 70% faster than the original algorithm. Results for case studies suggest that including ASHPs can support up to 16% higher renewable generation capacity compared to gas boilers, albeit with higher ASHP investment costs. The optimisation framework and results can be used to inform stakeholders such as policy-makers and network operators, to increase renewable energy capacity and aid the decarbonisation of domestic heating systems. 47 pages, 10 figures, 14 Tables
Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 6 citations 6 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint 2024Embargo end date: 01 Jan 2022Publisher:Elsevier BV Authors: De Mel, Ishanki; Klymenko, Oleksiy V.; Short, Michael;The optimal selection, sizing, and location of small-scale technologies within a grid-connected distributed energy system (DES) can contribute to reducing carbon emissions, consumer costs, and network imbalances. This is the first study to present an optimisation framework for obtaining discrete technology sizing and selection for grid-connected DES design, while simultaneously considering multiphase optimal power flow (MOPF) constraints to accurately represent unbalanced low-voltage distribution networks. An algorithm is developed to solve the resulting Mixed-Integer Nonlinear Programming (MINLP) formulation. It employs a decomposition based on Mixed-Integer Linear Programming (MILP) and Nonlinear Programming (NLP), and utilises integer cuts and complementarity reformulations to obtain discrete designs that are also feasible with respect to the network constraints. A heuristic modification to the original algorithm is also proposed to improve computational speed. Improved formulations for selecting feasible combinations of air source heat pumps (ASHPs) and hot water storage tanks are also presented. The algorithms outperform the existing state-of-the-art commercial MINLP solver, which fails to find any solutions in two instances. While feasible solutions were obtained for all cases, convergence was not achieved for all, especially for those involving the larger network. Where converged, the algorithm with the heuristic modification has achieved results up to 70% faster than the original algorithm. Results for case studies suggest that including ASHPs can support up to 16% higher renewable generation capacity compared to gas boilers, albeit with higher ASHP investment costs. The optimisation framework and results can be used to inform stakeholders such as policy-makers and network operators, to increase renewable energy capacity and aid the decarbonisation of domestic heating systems. 47 pages, 10 figures, 14 Tables
Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 6 citations 6 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert Applied Energy arrow_drop_down https://dx.doi.org/10.48550/ar...Article . 2022License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2023.122136&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV Edoardo Bertone; Oz Sahin; Rodney A. Stewart; Patrick X.W. Zou; Morshed Alam; Keith Hampson; Evan Blair;handle: 20.500.11937/61841 , 1959.3/440423 , 10072/379867
Abstract In Australia, the government spending on public buildings’ energy and water consumption is considerable; however the building energy and water retrofit market potential has been diminished by a number of barriers, especially financial. In contrast, in other advanced economies there are several reported financing strategies that have been shown to accelerate retrofit projects implementation. In this study, a coupled Bayesian Network – System Dynamics model was developed with the core aim to assess the likely influence of those novel financing options and procurement procedures on public building retrofit outcomes scenarios in the Australian context. A particular case-study focusing on Australian public hospitals was showcased as an example in this paper. Stakeholder engagement was utilised to estimate likely preferences and to conceptualise causal relationships of model parameters. The scenario modelling showed that a revolving loan fund supporting an energy performance contracting procurement procedure was preferred. Subsequently, the specific features of this preferred framework were optimised to yield the greatest number of viable retrofit projects over the long term. The results indicated that such a financing scheme would lead to substantial abatement of energy and water consumption, as well as carbon emissions. The strategic scenario analysis approach developed herein provides evidence-based support to policy-makers advocating novel financing and procurement models for addressing a government’s sustainability agenda in a financially responsible and net-positive manner.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 70 citations 70 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV Edoardo Bertone; Oz Sahin; Rodney A. Stewart; Patrick X.W. Zou; Morshed Alam; Keith Hampson; Evan Blair;handle: 20.500.11937/61841 , 1959.3/440423 , 10072/379867
Abstract In Australia, the government spending on public buildings’ energy and water consumption is considerable; however the building energy and water retrofit market potential has been diminished by a number of barriers, especially financial. In contrast, in other advanced economies there are several reported financing strategies that have been shown to accelerate retrofit projects implementation. In this study, a coupled Bayesian Network – System Dynamics model was developed with the core aim to assess the likely influence of those novel financing options and procurement procedures on public building retrofit outcomes scenarios in the Australian context. A particular case-study focusing on Australian public hospitals was showcased as an example in this paper. Stakeholder engagement was utilised to estimate likely preferences and to conceptualise causal relationships of model parameters. The scenario modelling showed that a revolving loan fund supporting an energy performance contracting procurement procedure was preferred. Subsequently, the specific features of this preferred framework were optimised to yield the greatest number of viable retrofit projects over the long term. The results indicated that such a financing scheme would lead to substantial abatement of energy and water consumption, as well as carbon emissions. The strategic scenario analysis approach developed herein provides evidence-based support to policy-makers advocating novel financing and procurement models for addressing a government’s sustainability agenda in a financially responsible and net-positive manner.
Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 70 citations 70 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Griffith University:... arrow_drop_down Griffith University: Griffith Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://hdl.handle.net/10072/379867Data sources: Bielefeld Academic Search Engine (BASE)Swinburne University of Technology: Swinburne Research BankArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2017.08.054&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 ItalyPublisher:Elsevier BV Fanciulli C; Abedi H; Merotto L; Donde R; De Iuliis S; Passaretti F;handle: 20.500.14243/344438
In recent years, the portable technology is receiving a great interest and significant improvement due to the progresses in electronic technology development and energy storage solutions. The decrease in power requirements for working energy systems, due to the increased efficiency and to the reduction in components size, opens the access to new solutions for power supplying. In particular, alternative backup systems for battery charging or replacement could be designed taking advantage of unconventional technologies. It is the case of small photovoltaic portable panels or fuel cells technology: in these solutions different sources are used to produce limited electrical powers required to keep devices on. In this paper, a thermoelectric solution for the power generation has been considered: the generator has been designed and assembled starting from a catalytic combustor. Catalytic combustion allows safe control of the processes, and the choice of a hydrocarbon fuel ensures the power availability and a fast recharge. The size of the system is set to fit a volume close to the one of AA batteries. The electrical power output obtained is close to 1 W with a cold side temperature below 40 °C. The limited values of these physical parameters allow obtaining a portable and safe device. The generator has been fully characterized in different ranges of fuel flow rates and the performances have been thoroughly analysed for processes optimization and efficiency improvement.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu65 citations 65 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.02.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 FrancePublisher:Elsevier BV Rachid Outbib; Daniel Hissel; Daniel Hissel; Stefan Giurgea; Stefan Giurgea; Yongdong Li; Zhongliang Li; Zhongliang Li;This paper proposes a data-driven diagnostic approach for Polymer Electrolyte Membrane Fuel Cell (PEMFC) systems. Fault detection and isolation (FDI) is realized by analyzing individual cell voltages. A feature extraction method Fisher Discriminant Analysis (FDA) and a multi-class classification method Directed Acyclic Graph Support Vector Machine (DAGSVM) are utilized successively to extract the useful features from raw data and classify the extracted features into various classes related to health states. Experimental data of two different stacks are used to validate the proposed approach. The results show that five concerned faults can be detected and isolated with a high accuracy. Moreover, the light computational cost of the approach enhances the possibility of its online implementation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu57 citations 57 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015 FrancePublisher:Elsevier BV Rachid Outbib; Daniel Hissel; Daniel Hissel; Stefan Giurgea; Stefan Giurgea; Yongdong Li; Zhongliang Li; Zhongliang Li;This paper proposes a data-driven diagnostic approach for Polymer Electrolyte Membrane Fuel Cell (PEMFC) systems. Fault detection and isolation (FDI) is realized by analyzing individual cell voltages. A feature extraction method Fisher Discriminant Analysis (FDA) and a multi-class classification method Directed Acyclic Graph Support Vector Machine (DAGSVM) are utilized successively to extract the useful features from raw data and classify the extracted features into various classes related to health states. Experimental data of two different stacks are used to validate the proposed approach. The results show that five concerned faults can be detected and isolated with a high accuracy. Moreover, the light computational cost of the approach enhances the possibility of its online implementation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu57 citations 57 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2015.03.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Authors: Kevin J. Kircher; K. Max Zhang;Abstract Efficient electric heat pumps have the potential to significantly reduce greenhouse gas emissions from heating and cooling buildings. However, heat pumps’ initial costs can be prohibitively high and their lifetime costs are only situationally competitive with incumbent technologies. Here we show that a business model based on heat purchase agreements could lower these barriers to heat pump adoption. In this business model, a user hosts a heat pump owned by an aggregator. The aggregator installs the heat pump at low or no initial cost to the user. The user buys the heat pump’s heat or cooling output from the aggregator. The aggregator buys the heat pump’s input electricity in the wholesale energy market and sells the flexibility of their aggregate electrical load in ancillary service markets. This paper presents the first economic analysis of heat purchase agreements as a third-party ownership model for electric heat pumps. We derive conditions under which a heat purchase agreement is mutually beneficial to the user and the aggregator. We also provide a method to fairly price heat and cooling. A case study of a typical United States home shows that a heat purchase agreement could more than double the value of a heat pump investment relative to the incumbent business model. The potential impact of this work is to reduce emissions both directly, by accelerating replacement of fossil-fueled or inefficient heating or cooling equipment, and indirectly, by helping power system operators reliably integrate wind and solar generation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 18 citations 18 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Authors: Kevin J. Kircher; K. Max Zhang;Abstract Efficient electric heat pumps have the potential to significantly reduce greenhouse gas emissions from heating and cooling buildings. However, heat pumps’ initial costs can be prohibitively high and their lifetime costs are only situationally competitive with incumbent technologies. Here we show that a business model based on heat purchase agreements could lower these barriers to heat pump adoption. In this business model, a user hosts a heat pump owned by an aggregator. The aggregator installs the heat pump at low or no initial cost to the user. The user buys the heat pump’s heat or cooling output from the aggregator. The aggregator buys the heat pump’s input electricity in the wholesale energy market and sells the flexibility of their aggregate electrical load in ancillary service markets. This paper presents the first economic analysis of heat purchase agreements as a third-party ownership model for electric heat pumps. We derive conditions under which a heat purchase agreement is mutually beneficial to the user and the aggregator. We also provide a method to fairly price heat and cooling. A case study of a typical United States home shows that a heat purchase agreement could more than double the value of a heat pump investment relative to the incumbent business model. The potential impact of this work is to reduce emissions both directly, by accelerating replacement of fossil-fueled or inefficient heating or cooling equipment, and indirectly, by helping power system operators reliably integrate wind and solar generation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 18 citations 18 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116489&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2025 GermanyPublisher:Elsevier BV Fabian Wüllhorst; Sebastian Schwarz; Nico Fuchs; Laura Maier; Antonello Monti; Dirk Müller;Applied energy 388, 125530 (2025). doi:10.1016/j.apenergy.2025.125530 Published by Elsevier Science, Amsterdam [u.a.]
Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2025 GermanyPublisher:Elsevier BV Fabian Wüllhorst; Sebastian Schwarz; Nico Fuchs; Laura Maier; Antonello Monti; Dirk Müller;Applied energy 388, 125530 (2025). doi:10.1016/j.apenergy.2025.125530 Published by Elsevier Science, Amsterdam [u.a.]
Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert Applied Energy arrow_drop_down Publikationsserver der RWTH Aachen UniversityArticle . 2025Data sources: Publikationsserver der RWTH Aachen Universityadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2025.125530&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu