- home
- Search
- Energy Research
- Restricted
- Embargo
- CA
- BE
- IR
- Energy Research
- Restricted
- Embargo
- CA
- BE
- IR
description Publicationkeyboard_double_arrow_right Article , Journal 2016Publisher:Elsevier BV Authors:Majid Sadeqzadeh;
Majid Sadeqzadeh
Majid Sadeqzadeh in OpenAIREAli Ghannadzadeh;
Ali Ghannadzadeh
Ali Ghannadzadeh in OpenAIREAmmonia production through more efficient technologies can be achieved using exergy analysis. Ammonia production is one of the most important but also one of most energy consuming processes in the chemical industry. Based on a panel of solutions previously developed, this study helps to identify potential areas of improvement using an exergy analysis that covers all aspects of conventional ammonia synthesis and separation. The total internal and external exergy losses are calculated as 3,152 and 6,364 kJ/kg, respectively. The process is then divided into five main functional blocks based on their exergy losses. The reforming block contains the largest exergy loss (3,098 kJ/kg) and thus the largest potential for improvement including preheating cold feed through an economizer, developing technology towards isobaric mixing, and pressure drop reduction in the secondary reformer as the main contributors to the irreversibility (1,302 kJ/kg) in this block. The second largest exergy loss resides in the ammonia synthesis block (3,075 kJ/kg) where solutions such as reduced temperature rise across the compressor, proper compressor isolation, reducing undesired components such as argon in the reactor feed, and using lower temperatures for reactor outlet streams, are proposed to decrease the exergy losses. Throttling process in the syngas separator is the key contributing mechanism for the irreversibility (1,635 kJ/kg exergy losses) in the gas upgrading block. The exergy losses in the residual ammonia removal block (833 kJ/kg exergy losses) are mainly due to the stripper and the absorber column where a modified column design might be helpful. The highest exergy loss in the preheating block belongs to the compressors (518 kJ/kg exergy losses) where a lower inlet temperature and better system isolation could help to reduce losses.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2016Data sources: DANS (Data Archiving and Networked Services)Energy Conversion and ManagementArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2015.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 23 citations 23 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2016Data sources: DANS (Data Archiving and Networked Services)Energy Conversion and ManagementArticle . 2016 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2015.11.040&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015Publisher:Elsevier BV Authors: Melissa Morselli; Matteo Semplice;Frederik De Laender;
Frederik De Laender
Frederik De Laender in OpenAIREPaul J. Van den Brink;
+1 AuthorsPaul J. Van den Brink
Paul J. Van den Brink in OpenAIREMelissa Morselli; Matteo Semplice;Frederik De Laender;
Frederik De Laender
Frederik De Laender in OpenAIREPaul J. Van den Brink;
Paul J. Van den Brink
Paul J. Van den Brink in OpenAIREAntonio Di Guardo;
Antonio Di Guardo
Antonio Di Guardo in OpenAIREpmid: 25967479
In ecological risk assessment, exposure is generally modelled assuming static conditions, herewith neglecting the potential role of emission, environmental and biomass dynamics in affecting bioavailable concentrations. In order to investigate the influence of such dynamics on predicted bioavailable concentrations, the spatially-resolved dynamic model "ChimERA fate" was developed, incorporating macrophyte and particulate/dissolved organic carbon (POC/DOC) dynamics into a water-sediment system. An evaluation against three case studies revealed a satisfying model performance. Illustrative simulations then highlighted the potential spatio-temporal variability of bioavailable concentrations after a pulsed emission of four chemicals in a system composed of a pond connected to its inflow and outflow streams. Changes in macrophyte biomass and POC/DOC levels caused exposure variations which were up to a factor of 4.5 in time and even more significant (several orders of magnitude) in space, especially for highly hydrophobic chemicals. ChimERA fate thus revealed to be a useful tool to investigate such variations and to identify those environmental and ecological conditions in which risk is expected to be highest.
The Science of The T... arrow_drop_down The Science of The Total EnvironmentArticle . 2015Data sources: DANS (Data Archiving and Networked Services)The Science of The Total EnvironmentArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.scitotenv.2015.04.072&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 18 citations 18 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert The Science of The T... arrow_drop_down The Science of The Total EnvironmentArticle . 2015Data sources: DANS (Data Archiving and Networked Services)The Science of The Total EnvironmentArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.scitotenv.2015.04.072&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Springer Science and Business Media LLC Authors:Ali Ghannadzadeh;
Ali Ghannadzadeh
Ali Ghannadzadeh in OpenAIREMajid Sadeqzadeh;
Majid Sadeqzadeh
Majid Sadeqzadeh in OpenAIREEthylene oxide production process is one of the highest energy consumers in chemical industry, and therefore even a slight improvement in its overall efficiency can have a significant impact on the sustainability of the process. Efficiency improvement can be carried out using the exergy-aided pinch analysis outlined in this paper. The overall exergy loss distribution in different unit operations of an ethylene oxide process was first evaluated and mapped out in the form of “visualized exergetic process flowsheet”. An initial analysis of the four main functional blocks of the process showed that the exothermic reaction block contained the largest exergy loss (6043 and 428 kJ/kg of internal and external losses, respectively) which can be reduced by isothermal mixing, as well as increasing reaction temperature and reduction in pressure drop. The absorption block was also estimated to have the second highest contribution with total exergy losses of 3640 kJ/kg which were mainly due to the cooling column. These losses were then recommended to be reduced by improvements in the concentration and temperature gradients along the tower. Following the block-wise analysis, exergy analysis was then carried out for individual unit operations in each block to pinpoint the main sources of thermal exergetic inefficiency. Thermal solutions to reduce losses were also proposed in accordance with the identified sources of inefficiency, leading to a comprehensive list of cold and hot process streams that could be introduced to reduce losses. Finally, pinch analysis was brought into action to estimate the minimum energy requirements, to select utilities, and to design heat exchanger network. Thus, the methodology used in this work took advantage of both exergy and pinch analyses. The combined thermal-exergy-based pinch approach helped to set energy targets so that all the thermal possible solutions supported by exergy analysis were considered, preventing exclusion of any hot or cold process stream with high potential for heat integration during pinch analysis. Results indicated that the minimum cold utility requirement could be reduced from 601.64 MW (obtained via conventional pinch analysis) to 577.82 MW through screening of streams by the combined methodology.
Clean Technologies a... arrow_drop_down Clean Technologies and Environmental PolicyArticle . 2017Data sources: DANS (Data Archiving and Networked Services)Clean Technologies and Environmental PolicyArticle . 2017 . Peer-reviewedLicense: Springer TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10098-017-1402-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 12 citations 12 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Clean Technologies a... arrow_drop_down Clean Technologies and Environmental PolicyArticle . 2017Data sources: DANS (Data Archiving and Networked Services)Clean Technologies and Environmental PolicyArticle . 2017 . Peer-reviewedLicense: Springer TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10098-017-1402-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2008Publisher:Wiley Authors: C. Bakker;Brian K. Sorrell;
Brian K. Sorrell
Brian K. Sorrell in OpenAIREPeter M. van Bodegom;
Peter M. van Bodegom
Peter M. van Bodegom in OpenAIRERien Aerts;
+1 AuthorsRien Aerts
Rien Aerts in OpenAIREC. Bakker;Brian K. Sorrell;
Brian K. Sorrell
Brian K. Sorrell in OpenAIREPeter M. van Bodegom;
Peter M. van Bodegom
Peter M. van Bodegom in OpenAIRERien Aerts;
Annelies Oosthoek;Rien Aerts
Rien Aerts in OpenAIREIn wetlands, a distinct zonation of plant species composition occurs along moisture gradients, due to differential flooding tolerance of the species involved. However, "flooding" comprises two important, distinct stressors (soil oxygen demand [SOD] and partial submergence) that affect plant survival and growth. To investigate how these two flooding stressors affect plant performance, we executed a factorial experiment (water depth x SOD) for six plant species of nutrient-rich and nutrient-poor conditions, occurring along a moisture gradient in Dutch dune slacks. Physiological, growth, and biomass responses to changed oxygen availability were quantified for all species. The responses were consistent with field zonation, but the two stressors affected species differently. Increased SOD increased root oxygen deprivation, as indicated by either raised porosity or increased alcohol dehydrogenase (ADH) activity in roots of flood-intolerant species (Calamagrostis epigejos and Carex arenaria). While SOD affected root functioning, partial submergence tended more to reduce photosynthesis (as shown both by gas exchange and 13C assimilation), leaf dark respiration, 13C partitioning from shoots to roots, and growth of these species. These processes were especially affected if the root oxygen supply was depleted by a combination of flooding and increased SOD. In contrast, the most flood-tolerant species (Juncus subnodulosus and Typha latifolia) were unaffected by any treatment and maintained high internal oxygen concentrations at the shoot : root junction and low root ADH activity in all treatments. For these species, the internal oxygen transport capacity was well in excess of what was needed to maintain aerobic metabolism across all treatments, although there was some evidence for effects of SOD on their nitrogen partitioning (as indicated by 865N values) and photosynthesis. Two species intermediate in flooding tolerance (Carex nigra and Schoenus nigricans) responded more idiosyncratically, with different parameters responding to different treatments. These results show that partial submergence and soil flooding are two very different stressors to which species respond in different ways, and that their effects on physiology, survival, and growth are interactive. Understanding species zonation with water regimes can be improved by a better appreciation of how these factors affect plant metabolism independently and interactively.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1890/07-0390.1&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 44 citations 44 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1890/07-0390.1&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2003Publisher:Elsevier BV Authors: S. Hippeli; Harald Mehling; Stefan Hiebler;Luisa F. Cabeza;
Luisa F. Cabeza
Luisa F. Cabeza in OpenAIREHot water heat stores with stratification are a common technology used in solar energy systems and reuse of waste heat. Adding a PCM module at the top of the water tank would give the system higher storage density, and compensate heat loss in the top layer. The work presented here includes experimental results and numerical simulation of the system using an explicit finite-difference method. Experiments and simulations were carried out using different cylindrical PCM modules. With only 1/16 of the volume of the store being PCM, 3/16 of water at the top of the store was held warm for 50% to 200% longer and the average energy density was increased by 20% to 45%. Furthermore, these 3/16 of water were reheated by the heat from the module after being cooled down in only 20 min.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0960-1481(02)00108-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 157 citations 157 popularity Top 1% influence Top 1% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0960-1481(02)00108-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type , Journal 2012Publisher:Informa UK Limited Authors:Jacques De Keyser;
Jacques De Keyser
Jacques De Keyser in OpenAIREMarie B. D'hooghe;
Marie B. D'hooghe
Marie B. D'hooghe in OpenAIREWhile the harmful effects of alcohol abuse are well documented, experimental and clinical data support a potential benefit of light to moderate alcohol consumption. Cross-sectional studies have suggested an association between alcohol consumption and multiple sclerosis (MS) disability. In the absence of prospective, longitudinal studies, the causal nature of this relationship cannot be established. It remains possible that patients with increased disability progression reduce their alcohol intake. Even though there is substantial evidence for anti-inflammatory effects of low-to-moderate doses of alcohol, the associations need to be interpreted very cautiously. This study discusses the current state of knowledge about MS and alcohol consumption, and the limitations in conducting research with retrospective data in patients with MS.
Expert Review of Neu... arrow_drop_down Expert Review of NeurotherapeuticsOther literature type . 2012Data sources: DANS (Data Archiving and Networked Services)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1586/ern.12.44&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 5 citations 5 popularity Average influence Average impulse Average Powered by BIP!
more_vert Expert Review of Neu... arrow_drop_down Expert Review of NeurotherapeuticsOther literature type . 2012Data sources: DANS (Data Archiving and Networked Services)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1586/ern.12.44&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013Publisher:Ovid Technologies (Wolters Kluwer Health) Authors: Mark P. Jensen;Johannes Vlaeyen;
Warren R. Nielson; Petra A. Karsdorp;Johannes Vlaeyen
Johannes Vlaeyen in OpenAIREpmid: 23247005
Activity pacing (AP) is a concept that is central to many chronic pain theories and treatments, yet there remains confusion regarding its definition and effects.To review the current knowledge concerning AP and integrate this knowledge in a manner that allows for a clear definition and useful directions for future research.A narrative review of the major theoretical approaches to AP and of the empirical evidence regarding the effects of AP interventions, followed by an integrative discussion.The concept of AP is derived from 2 main traditions: operant and energy conservation. Although there are common elements across these traditions, significant conceptual and practical differences exist, which has led to confusion. Little empirical evidence exists concerning the efficacy of AP as a treatment for chronic pain.Future research on AP should be based on a clear theoretical foundation, consider the context in which the AP behavior occurs and the type of pacing problem ("underactivity" vs. "overactivity"), and should examine the impact of AP treatment on multiple clinical outcomes. We provide a provisional definition of AP and specific recommendations that we believe will move the field forward.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1097/ajp.0b013e3182608561&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 115 citations 115 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1097/ajp.0b013e3182608561&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014Publisher:Elsevier BV Authors:Camila Barreneche;
Camila Barreneche;Camila Barreneche
Camila Barreneche in OpenAIRELuisa F. Cabeza;
Luisa F. Cabeza
Luisa F. Cabeza in OpenAIREM. Elena Navarro;
+2 AuthorsM. Elena Navarro
M. Elena Navarro in OpenAIRECamila Barreneche;
Camila Barreneche;Camila Barreneche
Camila Barreneche in OpenAIRELuisa F. Cabeza;
Luisa F. Cabeza
Luisa F. Cabeza in OpenAIREM. Elena Navarro;
A. Inés Fernández;M. Elena Navarro
M. Elena Navarro in OpenAIREM. Niubó;
M. Niubó
M. Niubó in OpenAIREAbstract In recent years, the overall energy consumption is increasing significantly and the energy consumption in the building sector represents over 30% of the global ones in developed countries. Thermal energy storage (TES) using phase change materials (PCM), which are materials able to store high amounts of energy as latent heat, is suggested as a possible solution to decrease the energy consumption. The authors of this paper developed materials able to encapsulate/stabilize PCM in addition to isolate an industrial residue from the steel recycling process: electrical arc furnace dust (EAFD). This waste is a hazardous dust, and when it is combined with a polymeric matrix produce dense sheet materials suitable for multilayered constructive systems. In this paper the physical, mechanical, thermal and acoustical characterization of two new materials with EAFD and PCM in a polymeric matrix for constructive system is presented. The results are compared with those obtained for one commercial dense sheet material available in the market, Texsound commercialized by TEXSA (Spain). The new dense sheet materials developed in this paper have similar acoustic properties compared to the results obtained for the commercial material and are competitive with it, even better because the new material incorporates PCM which increases the thermal inertia of final constructive system.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2013.09.004&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 16 citations 16 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2013.09.004&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022 SpainPublisher:Elsevier BV Authors: Boquera, Laura; Castro Chicot, José Ramón; Pisello, Anna Laura; Fabiani, Claudia; +3 AuthorsBoquera, Laura; Castro Chicot, José Ramón; Pisello, Anna Laura; Fabiani, Claudia; D'Alessandro, Antonella; Ubertini, Filippo; Cabeza, Luisa F.;The incorporation of recycled materials in concrete as a partial replacement of cement is becoming an alternative strategy for decreasing energy-intensive and CO2 emissions imputable to the cement manufacture, while investigating new potential uses of such multifunctional materials for environmental sustainability opportunities. Therefore, low-cost and worldwide availability of by-products materials is being assessed for sensible heat thermal energy storage applications based on cementitious materials. A greater concern is especially required focusing on the thermal stability of cement paste under high temperature cycled conditions. Moreover, compatibility between cement type and supplementary cementitious materials is determinant for the proper performance reliability. In this study, benchmark cement types were selected, i.e., ordinary Portland and calcium aluminate. Six supplementary cementitious materials were added to both types of cement in a content of 10 % and 25 %. Thermo-mechanical properties were studied before and after 10 thermal cycles from 290 to 650 ◦C. Results after thermal cycling showed that calcium aluminate cement paste mixtures maintained their integrity. However, most ordinary Portland cement paste mixtures were deteriorated: only mixtures with 25 % cement replacement with chamotte, flay ash, and ground granulated blast furnace slag remained without cracks. Calcium aluminate cement paste mixtures obtained the highest compressive strength, for partial replacement of cement with 10 % of chamotte, ground granulated blast furnace slag, and iron silicate. The incorporation of supplementary cementitious materials did not increase the thermal conductivity. This work was partially funded by the Ministerio de Ciencia, Innovación y Universidades de España (RTI2018-093849-B-C31 - MCIU/AEI/FEDER, UE) and by the Ministerio de Ciencia, Innovación y Universidades - Agencia Estatal de Investigación (AEI) (RED2018-102431-T). The authors at University of Lleida would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537). GREiA is certified agent TECNIO in the category of technology developers from the Government of Catalonia. This work is partially supported by ICREA under the ICREA Academia programme and by the Italian project ‘SOS-CITTA’ supported by Fondazione Cassa di Risparmio di Perugia under grant agreement No 2018.0499.026. Laura Boquera acknowledgments are due to the PhD school in Energy and Sustainable Development from University of Perugia. Laura Boquera would like to acknowledge the financial support provided by UNIPG – CIRIAF InpathTES project. The authors also thank the companies that provided the material to make possible this experimental research: Arciresa, Abrasivos Mendiola EDERSA—Masaveu Industria, General Admixtures S.p.A, Mapei, Ciments Molins industrial, and Promsa for the material supplied in this research. Financial support of the UNIPG-CIRIAF team has been achieved from the Italian Ministry of University and Research (MUR) in the framework of the Project FISR 2019: “Eco Earth” (code 00245) and it is gratefully acknowledged.
Repositori Obert UdL arrow_drop_down Journal of Energy StorageArticle . 2022 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.est.2022.105370&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Repositori Obert UdL arrow_drop_down Journal of Energy StorageArticle . 2022 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.est.2022.105370&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2011Publisher:Elsevier BV Authors:Frank Bruno;
Frank Bruno
Frank Bruno in OpenAIRELuisa F. Cabeza;
Luisa F. Cabeza
Luisa F. Cabeza in OpenAIREAlbert Castell;
Albert Castell
Albert Castell in OpenAIREMartin Belusko;
Martin Belusko
Martin Belusko in OpenAIREAbstract Thermal energy storage systems for both heat and cold are necessary for many industrial processes. High energy density and high power capacity are desirable properties of the storage. The use of latent heat increases the energy density of the storage tank with high temperature control close to the melting point. Tube in PCM tank is a very promising system that provides high packing factor. This work presents an experimental study of a PCM tank for cold storage applications. Two different configurations and different flow rates of the heat transfer fluid were studied. The effectiveness of the PCM storage system was defined as that of a heat exchanger. The results showed that the heat exchange effectiveness of the system did not vary with time, decreased with increasing flow rate and increased with increasing heat transfer area. The effectiveness was experimentally determined to only be a function of the ratio m ˙ /A. This equation was found to be adequately be used to design a PCM storage system, and a case study is presented. It was shown that the tube in tank design together with a low temperature PCM is suitable as a thermal storage facility for cold storage.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2011.03.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 122 citations 122 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2011.03.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu