description Publicationkeyboard_double_arrow_right Article , Journal 2015Publisher:Elsevier BV Yuechao Deng; Zhongliang Liu; Yaohua Zhao; Lincheng Wang;Zhenhua Quan;
Zhenhua Quan
Zhenhua Quan in OpenAIREAbstract This paper presented a novel method of dissipating solar photovoltaic heat based on the technology of micro-heat-pipe array and the utilization of photovoltaic-cell waste heat. This novel technology solved the problems of low PV electrical efficiency and thermal failure caused by high cell temperature, greatly increased the comprehensive utilization efficiency of solar energy, and extended the service life of photovoltaic modules. One-year experiments were conducted to investigate the electrical and thermal performance of a forced-circulation, household-type photovoltaic/thermal system based on micro-heat-pipe array in Beijing, China. Test results showed that on the four typical days in different seasons, the average electrical efficiencies were 13.76%, 11.92%, 13.71%, and 14.65%; the average thermal efficiencies were 31.62%, 33.07%, 24.99%, and 17.24%; and the average total efficiencies were 45.38%, 44.99%, 38.70%, 31.89%, respectively. The system met the demand of power supply on sunny days and the demand of hot water between March and November, except in cloudy days. These experimental results can provide basis and reference for practical applications of the system.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2015.09.067&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 58 citations 58 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2015.09.067&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2018Publisher:IOP Publishing Authors: Jingjing Lu; Yi Wang; Xu Hao;IOP Conference Serie... arrow_drop_down IOP Conference Series Earth and Environmental ScienceArticle . 2018 . Peer-reviewedLicense: CC BYData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/1755-1315/170/3/032009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert IOP Conference Serie... arrow_drop_down IOP Conference Series Earth and Environmental ScienceArticle . 2018 . Peer-reviewedLicense: CC BYData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/1755-1315/170/3/032009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2019Publisher:IOP Publishing Yang Lan; Shuxiang Song; Haiying Xia; Xiao Su; Jianping Jiang;Abstract In demand of remote control of photographic equipment, we design a remote-control system for photographic equipment. The system uses the stabilizer as the platform to realize the transmission of the state parameters of photographic equipment and stabilizer to the mobile device by the self-designed wireless communication interaction protocol and control protocol. It can also control the camera equipment and stabilizer according their states. The test results show that the remote-control system of the photographic equipment designed in this paper meets the design requirements, facilitates the user’s surveillance filming work and harmonizes the user experience.
IOP Conference Serie... arrow_drop_down IOP Conference Series Materials Science and EngineeringArticle . 2019 . Peer-reviewedLicense: CC BYData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/1757-899x/569/4/042017&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert IOP Conference Serie... arrow_drop_down IOP Conference Series Materials Science and EngineeringArticle . 2019 . Peer-reviewedLicense: CC BYData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1088/1757-899x/569/4/042017&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 United KingdomPublisher:Elsevier BV Funded by:EC | REMOURBANEC| REMOURBANAuthors:Ashfaq, A;
Ashfaq, A
Ashfaq, A in OpenAIREIanakiev, A;
Ianakiev, A
Ianakiev, A in OpenAIREThe hydraulic balance of heating network is considered as a pre-condition for the implementation of low temperature district heating (LTDH). Its imbalance result into high energy consumption and heat-losses in the network. In this study, a novel hydraulic model is presented which investigates hydraulic imbalance in the LTDH network, using real weather and hourly monitored operational heating data from an existing boiler based building. Analysis of delta t in space-heating system shows that the delta t is maximum when the outside air temperature is lowest and it decreases with increase in outside air temperature. Furthermore, the hydraulic imbalance is analysed for four different control scenarios with the aim to find an optimum scenario with minimum pumping power, energy consumption and heat-losses in the LTDH network. Results show that the hydraulic imbalance is due to the absence of flow-limiters and balancing valves on the return pipe and thermostatic radiator valves (TRVs) alone are unable to maintain hydraulic balance in the space-heating system of buildings. Moreover, the control scenario with variable flow-rate and fixed supply water temperature from the sub-station is found to be optimum. Compared to the constant flow-rate scenario, the pumping power, energy consumption and heat-losses in the LTDH network are reduced by approximately 2%, 63% and 14%, respectively.
CORE arrow_drop_down Nottingham Trent Institutional Repository (IRep)Article . 2018Data sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.07.001&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 20 citations 20 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
visibility 3visibility views 3 download downloads 60 Powered bymore_vert CORE arrow_drop_down Nottingham Trent Institutional Repository (IRep)Article . 2018Data sources: CORE (RIOXX-UK Aggregator)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.07.001&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Abstract In a passive nuclear plant, the main control room must provide self-support functions for 72 h after an accident occurs. In this isolation mode, the heat generated by indoor occupants and equipment should be removed by using concrete walls that are 610 mm thick, and the finned ceiling made of concrete should maintain thermal habitability. However, the finned ceiling design has not been studied in normal buildings, and the cooling storage effect of plate-shaped fins is usually ignored during the design phase. In this study, a novel parametric resistance–capacitance thermal network is proposed to simulate the thermal performance of different fin-plate layout forms in the case of an accident. An experiment was conducted on a 1200 mm × 1200 mm × 610 mm fin-concrete module for 72 h to validate the model under constant air temperature conditions. Based on the model, multi-objective optimization was conducted to obtain optimal solution sets by using a radial basis function approximation model. The results show that the optimal performance indicators can be classified into unsteady and quasi-steady states, in which the dominant factors for heat transfer include the heat transfer area and the thickness of the finned plate, respectively. Further, the optimal solution sets for different convection and heating conditions obtained through an optimization process are used to design a fin layout based on actual temperature control demands and cooling storage.
Applied Thermal Engi... arrow_drop_down Applied Thermal EngineeringArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2021.117146&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 3 citations 3 popularity Top 10% influence Average impulse Average Powered by BIP!
more_vert Applied Thermal Engi... arrow_drop_down Applied Thermal EngineeringArticle . 2021 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.applthermaleng.2021.117146&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV Zongyang Zhang; Zhiyuan Wang; Chao Kang; Fang Yu; Zixin Ma; Jie Guo;In grounding fault of DC system, overvoltage will appear on equipment nodes in converter station. Due to different operation mode and equipment type, it is very different from overvoltage in AC system. Based on Shanghaimiao–Linyi ±800kV Ultra High Voltage Direct Current (UHVDC) transmission project, this paper studies the converter station overvoltage characteristics under the conditions of DC pole line grounding, DC bus grounding and converter transformer valve side grounding fault, then analyzes the influence of smoothing reactor, filter capacitor and grounding pole line on overvoltage. In grounding fault at DC pole line near the converter station, the maximum overvoltage occurs on the inductance of DC filter, which is 592.75kV; In grounding fault at the top of the high voltage converter valve, the maximum overvoltage occurs on the neutral bus, which is 272.17kV. Increasing the inductance or capacitance of the smoothing reactor and filter capacitor, shortening the length of grounding electrode wire can significantly reduce the amplitude and steepness of overvoltage. The calculation results provide a reference for the internal overvoltage suppression of DC converter station with layered access at the inverter side.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.egyr.2022.01.231&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.egyr.2022.01.231&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Other literature type 2013Publisher:American Society of Mechanical Engineers Huan Chen; Zeng-hui Wang; Jie Liu; Wen-Qiang Lu; Lei Gao;The steady-state phase distribution and the structural parameters have been taken as the input for the nuclear physics calculation in the ADS windowless spallation target. The distribution of the extreme large power density of the heat load is imported back as the source term in the energy equation. Then temperature distribution is obtained based on the flow process and heat transfer. The preliminary results show that the temperature distribution reaches the steady-state and its shape is like the broken wings of the butterfly. This is very important for the further design and optimization of the ADS windowless spallation target. So the two-way coupling simulation of the heat transfer process is successfully performed between the computational fluid dynamics and the nuclear physics simulation.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1115/icone21-15903&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu3 citations 3 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1115/icone21-15903&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Wiley Authors:Lorenzo Colone;
Lorenzo Colone
Lorenzo Colone in OpenAIRENikolay Dimitrov;
Nikolay Dimitrov
Nikolay Dimitrov in OpenAIREDaniel Straub;
Daniel Straub
Daniel Straub in OpenAIREdoi: 10.1002/we.2352
AbstractWe devise a methodology to predict failures in wind turbine drive‐train components and quantify its utility. The methodology consists of two main steps. The first step is the set up of a predictive model for shutdown events, which is able to raise an alarm in advance of the fault‐induced shutdown. The model is trained on data for shutdown events retrieved from the alarm log of an offshore wind farm. Here, it is assumed that the timely prediction of low‐severity events, typically caused by abnormal component operation, allows for an intervention that can prevent premature component failures. The prediction models are based on statistical classification using only supervisory control and data acquisition (SCADA) data. In the second step, the shutdown prediction model is combined with a cost model to provide an estimate of the benefits associated with implementing the predictive maintenance system. This is achieved by computing the maximum net utility attainable as a function of the model performance and efficiency of intervention carried out by the user. Results show that the system can be expected to be cost‐effective under specific conditions. A discussion about potential improvements of the approach is provided, along with suggestions for further research in this area.
Wind Energy arrow_drop_down Wind EnergyArticle . 2019 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/we.2352&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 19 citations 19 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Wind Energy arrow_drop_down Wind EnergyArticle . 2019 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/we.2352&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Other literature type 2018 United StatesPublisher:American Institute of Mathematical Sciences (AIMS) Authors:Reza, Mohammad T.;
Nover, Jessica; Wirth, Benjamin; Coronella, Charles J.;Reza, Mohammad T.
Reza, Mohammad T. in OpenAIREhandle: 11714/5206
In this study, feasibility of selected nutrient sequestration during hydrothermal carbonization (HTC) was tested for three different HTC temperatures (180, 230, and 300 °C). To study the nutrient sequestration in solid from liquid solution, sugar and salt solutions were chosen as HTC feedstock. Glucose was used as carbohydrate source and various salts e.g., ammonium hydrophosphate, potassium chloride, potassium sulfate, and anhydrous ferric chloride were used as source of nitrogen and phosphorus, potassium, and iron, respectively. Solid hydrochar was extensively characterized by means of elemental, ICP-OES, SEM-EDX, surface area, pore volume and size, and ATR-FTIR to determine nutrients’ sequestration as well as hydrochar quality variation with HTC temperatures. The spherical mesoporous hydrochars produced during HTC have low surface area in the range of 1.0–3.5 m2 g?1. Hydrochar yield was increased about 10% with the increase of temperature from 180 °C to 300 °C. Nutrient sequestration was also increased with HTC temperature. In fact, around 71, 31, and 23 wt% nitrogen, iron, and phosphorus were sequestered at 300 °C, respectively. Potassium sequestration was very low throughout the HTC and maximum 5.2% was observed in solid during HTC.
University of Nevada... arrow_drop_down University of Nevada, Reno: ScholarWorks RepositoryArticle . 2018License: CC BYFull-Text: http://hdl.handle.net/11714/5206Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3934/energy.2018.2.269&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert University of Nevada... arrow_drop_down University of Nevada, Reno: ScholarWorks RepositoryArticle . 2018License: CC BYFull-Text: http://hdl.handle.net/11714/5206Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3934/energy.2018.2.269&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2015Publisher:Elsevier BV Authors:Wai Lok Woo;
Van-Tung Phan;Wai Lok Woo
Wai Lok Woo in OpenAIREThillainathan Logenthiran;
Thillainathan Logenthiran
Thillainathan Logenthiran in OpenAIREShort-term generation scheduling is an important function in daily operational planning of power systems. It is defined as optimal scheduling of power generators over a scheduling period while respecting various generator constraints and system constraints. Objective of the problem includes costs associated with energy production, start-up cost and shut-down cost along with profits. The resulting problem is a large scale nonlinear mixed-integer optimization problem for which there is no exact solution technique available. The solution to the problem can be obtained only by complete enumeration, often at the cost of a prohibitively computation time requirement for realistic power systems. This paper presents a hybrid algorithm which combines Lagrangian Relaxation (LR) together with Evolutionary Algorithm (EA) to solve the problem in cooperative and competitive energy environments. Simulation studies were carried out on different systems containing various numbers of units. The outcomes from different algorithms are compared with that from the proposed hybrid algorithm and the advantages of the proposed algorithm are briefly discussed.
International Journa... arrow_drop_down International Journal of Electrical Power & Energy SystemsArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefInternational Journal of Electrical Power & Energy SystemsJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijepes.2014.07.044&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 20 citations 20 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Electrical Power & Energy SystemsArticle . 2015 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefInternational Journal of Electrical Power & Energy SystemsJournalData sources: Microsoft Academic Graphadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.ijepes.2014.07.044&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu