- home
- Search
- Energy Research
- 7. Clean energy
- 11. Sustainability
- 3. Good health
- Energy and Buildings
- Energy Research
- 7. Clean energy
- 11. Sustainability
- 3. Good health
- Energy and Buildings
description Publicationkeyboard_double_arrow_right Article , Journal 2014 SpainPublisher:Elsevier BV Authors: Edwin Rodriguez-Ubinas; Sergio Rodriguez; Karsten Voss; Marija S. Todorovic;Given the global energy and environmental situation, the European Union has been issuing directives with increasingly demanding requirements in term of the energy efficiency in buildings. The international competition of sustainable houses, Solar Decathlon Europe (SDE), is aligned with these European objectives. SDE houses are low energy solar buildings that must reach the near to zero energy houses’ goal. In the 2012 edition, in order to emphasize its significance, the Energy Efficiency Contest was added. SDE houses’ interior comfort, functioning and energy performance is monitored. The monitoring data can give an idea about the efficiency of the houses. However, a jury comprised by international experts is responsible for carrying out the houses energy efficiency evaluation. Passive strategies and houses services are analyzed. Additionally, the jury's assessment has been compared with the behavior of the houses during the monitoring period. Comparative studies make emphasis on the energy aspects, houses functioning and their interior comfort. Conclusions include thoughts related with the evaluation process, the results of the comparative studies and suggestions for the next competitions.
Energy and Buildings arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2014 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2014.06.019&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 54 citations 54 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy and Buildings arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2014 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2014.06.019&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2003Publisher:Elsevier BV Authors: Hisashi Kotani; Toshio Yamanaka; Ryuji Satoh;Abstract Light wells in the centers of high-rise apartment buildings in Japan are called ‘Voids’. Gas water-heaters built into Voids discharge exhaust gas so a large enough opening has to be designed at the bottom of a Void to keep the indoor air quality (IAQ) acceptable. In order to secure the IAQ in the Void from contamination, a simple calculation method of the ventilation rate induced by wind force and thermal buoyancy through openings at the bottom, along with heat sources such as water-heaters, is presented. The accuracy of this calculation method was examined by wind tunnel testing. As a result, it turned out that the simple calculation methods introduced in this study were valid for predicting the vertical temperature distribution and ventilation rates in Voids.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0378-7788(02)00166-4&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 27 citations 27 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0378-7788(02)00166-4&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2011Publisher:Elsevier BV Authors: Giacomo Bizzarri;Abstract This article focuses on the results obtained by the enforcement of a original greenhouse gas emissions policy, issued in recent years in several municipalities in Northern Italy. The Municipality of Reggio Emilia was one of the firsts in Italy to develop and adopt a voluntary building energy-consumption certification method called Ecoabita, aiming to promote energy efficiency in buildings over its jurisdiction. Several reasons make this project innovative: first, the certification method has been processed through and verified by a quality international agency, secondly the procedure is assisting financial-incentive policies both on mandatory (European Directive 2002/91/CE) and voluntary basis (Municipality Protocol Ecoabita), finally it allows to obtain eligible credits for avoided emissions that can be negotiated on the CO2 exchange market. With specific reference to Reggio Emilia case, acknowledged the amount of actions, that are normally scheduled in the municipality throughout a year, it has been evaluated the benefit, in terms of environmental improvement, descended from the protocol, also projecting their trend in future years up to 2020 as well, demonstrating the scheduled interventions are fundamental in sought of the achievement of the Kyoto and Copenhagen commitments. The entire procedure has been developed in accordance to the parameters given by UNFCCC for these kinds of analyses and has been recently confirmed to be one of the most accurate international accounting procedure by a survey developed by the scientific committee of the European Project LIFE-LAKS.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2011.05.027&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 8 citations 8 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2011.05.027&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint 2023Embargo end date: 01 Jan 2023Publisher:Elsevier BV Authors: Maomao Hu; Ram Rajagopal; Jacques A. de Chalendar;arXiv: 2304.13175
Building energy flexibility has been increasingly demonstrated as a cost-effective solution to respond to the needs of energy networks, including electric grids and district cooling and heating systems, improving the integration of intermittent renewable energy sources. Adjusting zonal temperature set-points is one of the most promising measures to unlock the energy flexibility potential of central air conditioning systems in complex commercial buildings. However, most existing studies focused on quantifying the energy flexibility on the building level since only building-level energy consumption is normally metered in commercial buildings. This study aims to investigate the impacts of temperature set-point adjustment strategies on zone-level thermal and energy performance by developing a non-intrusive data-driven load disaggregation method (i.e., a virtual zonal power meter). Three university buildings in Northern California were selected to test the proposed load disaggregation method. We found that heterogeneities of energy use and energy flexibility existed across not only buildings but also air handling units (AHUs) and zones. Moreover, a small number of zones accounted for a large amount of energy use and energy flexibility; and the most energy-intensive zones are not necessarily the most energy-flexible zones. For the three tested buildings, the top 30% most energy-intensive zones accounted for around 60% of the total energy use; and the top 30% most energy-flexible zones provided around 80% of the total energy flexibility. The proposed method enables the electric grid or district energy system operators to regard the controlled energy-flexible entities as a fleet of AHUs or zones instead of a fleet of buildings and helps unlock the possibility for targeted demand flexibility strategies that balance zone-by-zone energy reduction with zone-by-zone costs to occupants. 33 pages, 18 figures
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.113339&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.113339&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Authors: Kijung Kim; Changhyo Yi; Seungil Lee;Abstract A change in the thermal environment of an urban area affects health, living conditions, and energy consumption. In urban planning, urban parks are one of the methods for improving the thermal environment and saving cooling energy. Urban park construction can mitigate temperature, but it also causes urban development by increasing local attractiveness. To achieve efficient energy saving through parks in urban planning, the purpose of this study is to investigate the relationship between building energy consumption and urban characteristics both before and after the construction of an urban park. This study targeted Seoul's Gyeongui line forest, which was recently converted into a linear park on the former railway as an urban regeneration project. We analyzed the relationship between energy consumption and urban characteristics using a regression model, focusing on the changes before and after the construction. In this study, urban characteristics include environment, building physical characteristics, and economic variables. The results show that the construction of the urban park reduced not only temperature but also building energy consumption. The energy reduction effect of the park was limited to a marginal distance. Meanwhile, the urban park construction caused land prices to rise and prompted new development, and this changed the urban characteristics of the area and affected energy consumption. Despite changes in urban characteristics, urban park planning is an effective methods of reducing the energy consumption involved in cooling urban areas. We recommend comprehensive consideration of the urban factors when making park policy to reduce urban temperature and energy consumption.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.03.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 21 citations 21 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.03.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal , Other literature type 2019Embargo end date: 14 Apr 2020Publisher:Elsevier BV Authors: Gupta, Rajat; Bruce-Konuah, Adorkor; Howard, Alastair;Abstract This paper empirically evaluates the extent of energy resilience achieved in a socially-deprived community in Oxford, through deployment of solar photovoltaic (PV) systems and smart batteries (internet enabled and controllable) across a cluster of 82 dwellings (households). The methodological approach comprised dwelling and household surveys, along with high frequency monitoring of household electricity consumption, solar PV generation, battery charge and discharge data. In the monitored households, average daily electricity consumption was found to be positively related with dwelling size, number of occupants and number of appliances used. Although 117 MWh of PV electricity was generated within a year across 74 dwellings, peak generation did not match peak consumption, demonstrating the need for battery storage. Home batteries were found to increase self-consumption of PV electricity and offset grid demand through discharge of stored PV electricity marginally at an average of 6%, depending on the size of the PV system, surplus PV electricity available and size of the battery. Aggregating solar generation and storage at a community level showed that peak grid electricity demand between 17:00 and 19:00 was reduced by 8% through the use of smart batteries across 74 dwellings. In future, a local energy sharing scheme could be developed, wherein not all dwellings would need to have solar PV systems, but rather have internet enabled batteries that could be monitored and controlled virtually.
Energy and Buildings arrow_drop_down Oxford Brookes University: RADARArticle . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADAROxford Brookes University: RADAROther literature type . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADARadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.04.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 56 citations 56 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy and Buildings arrow_drop_down Oxford Brookes University: RADARArticle . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADAROxford Brookes University: RADAROther literature type . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADARadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.04.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1981Publisher:Elsevier BV Authors: G.B. Varey; Ashley F. Emery; C.J. Kippenhan; D.R. Heerwagen;Abstract A numerical simulation program, based upon a finite difference nodal network, was used to simulate two Los Alamos test cells (one single and one multi-room cell) and a typical residence — all of which were exposed to intense insolation and large changes in ambient weather conditions. For the test cells, the predicted surface and globe temperatures are in good agreement with the measured values and indicate the acceptability of thermal modeling. The program was used to predict the behavior of a residential structure. The process of refining these predictions, guided by observations, led to the development of a stepwise simulation methodology. The insights gained as a result of this interdisciplinary involvement have been stimulating and instructive. The importance of recognizing the differences in the thought processes and the work styles of the several professions has been demonstrated. The most effective simulation methodology was that based upon human comfort, which appeared to be a common perception amongst all the program users.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0378-7788(81)90012-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 9 citations 9 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0378-7788(81)90012-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014 AustraliaPublisher:Elsevier BV Authors: Hirning, Michael; Isoardi, Gillian; Cowling, Ian;Abstract This study presents the largest-known, investigation on discomfort glare with 493 surveys collected from five green buildings in Brisbane, Australia. The study was conducted on full-time employees, working under their everyday lighting conditions, all of whom had no affiliation with the research institution. The survey consisted of a specially tailored questionnaire to assess potential factors relating to discomfort glare. Luminance maps extracted from high dynamic range (HDR) images were used to capture the luminous environment of the occupants. Occupants who experienced glare on their monitor and/or electric glare were excluded from analysis leaving 419 available surveys. Occupants were more sensitive to glare than any of the tested indices accounted for. A new index, the UGP was developed to take into account the scope of results in the investigation. The index is based on a linear transformation of the UGR to calculate a probability of disturbed persons. However all glare indices had some correlation to discomfort, and statistically there was no difference between the DGI, UGR and CGI. The UGP broadly reflects the demographics of the working population in Australia and the new index is applicable to open plan green buildings.
Queensland Universit... arrow_drop_down Queensland University of Technology: QUT ePrintsArticle . 2014License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2013.11.053&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 109 citations 109 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Queensland Universit... arrow_drop_down Queensland University of Technology: QUT ePrintsArticle . 2014License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2013.11.053&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2009Publisher:Elsevier BV Ewa Wäckelgård; Joakim Widén; Erik Dahlquist; Iana Vassileva; Magdalena Lundh; Kajsa Ellegård;Time-use data, describing in detail the everyday life of household members as high-resolved activity sequences, have a largely unrealized potential of contributing to domestic energy demand modelli ...
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2009.02.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 302 citations 302 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2009.02.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Ahmad Ihsan Mohd Yassin; Rijalul Fahmi Mustapa; Atiqah Hamizah Mohd Nordin; Nofri Yenita Dahlan;Abstract Energy conservation measures (ECM) through awareness, good housekeeping measures and demand side management are the first step that must be implemented to achieve energy savings in any building. The energy savings from the implemented ECM must be properly quantified to demonstrate its effectiveness and success. Quantifying energy savings using Multiple Linear Regression (MLR) model have been gaining popularity due to its simple approach but its inability to model and predict dynamic behavior that involves non-linearity relationships can be seen as its main drawback. Thus, the objective of this work is twofold, where the first fold is to implement an ECM program in a building and the second fold is to determine the energy saved from the ECM program using Non-Linear autoregressive with Exogenous inputs artificial neural network (NARX-ANN). The ECM program was executed at one floor of a university building. NARX-ANN was used to model the baseline energy consumption and determine the energy savings following the International Performance Measurement and Verification Protocol (IPMVP). A comparison was made between the MLR and the NARX-ANN model where the latter provides higher accuracy in statistical error compared to the MLR model. The energy savings from the awareness program determined by the NARX-ANN model was 170.84 kWh with Mean Square Error and Root Mean Square accuracy of 0.6068 and 0.7790 respectively.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2020.109899&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 29 citations 29 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2020.109899&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2014 SpainPublisher:Elsevier BV Authors: Edwin Rodriguez-Ubinas; Sergio Rodriguez; Karsten Voss; Marija S. Todorovic;Given the global energy and environmental situation, the European Union has been issuing directives with increasingly demanding requirements in term of the energy efficiency in buildings. The international competition of sustainable houses, Solar Decathlon Europe (SDE), is aligned with these European objectives. SDE houses are low energy solar buildings that must reach the near to zero energy houses’ goal. In the 2012 edition, in order to emphasize its significance, the Energy Efficiency Contest was added. SDE houses’ interior comfort, functioning and energy performance is monitored. The monitoring data can give an idea about the efficiency of the houses. However, a jury comprised by international experts is responsible for carrying out the houses energy efficiency evaluation. Passive strategies and houses services are analyzed. Additionally, the jury's assessment has been compared with the behavior of the houses during the monitoring period. Comparative studies make emphasis on the energy aspects, houses functioning and their interior comfort. Conclusions include thoughts related with the evaluation process, the results of the comparative studies and suggestions for the next competitions.
Energy and Buildings arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2014 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2014.06.019&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 54 citations 54 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy and Buildings arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2014 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2014.06.019&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2003Publisher:Elsevier BV Authors: Hisashi Kotani; Toshio Yamanaka; Ryuji Satoh;Abstract Light wells in the centers of high-rise apartment buildings in Japan are called ‘Voids’. Gas water-heaters built into Voids discharge exhaust gas so a large enough opening has to be designed at the bottom of a Void to keep the indoor air quality (IAQ) acceptable. In order to secure the IAQ in the Void from contamination, a simple calculation method of the ventilation rate induced by wind force and thermal buoyancy through openings at the bottom, along with heat sources such as water-heaters, is presented. The accuracy of this calculation method was examined by wind tunnel testing. As a result, it turned out that the simple calculation methods introduced in this study were valid for predicting the vertical temperature distribution and ventilation rates in Voids.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0378-7788(02)00166-4&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 27 citations 27 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0378-7788(02)00166-4&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2011Publisher:Elsevier BV Authors: Giacomo Bizzarri;Abstract This article focuses on the results obtained by the enforcement of a original greenhouse gas emissions policy, issued in recent years in several municipalities in Northern Italy. The Municipality of Reggio Emilia was one of the firsts in Italy to develop and adopt a voluntary building energy-consumption certification method called Ecoabita, aiming to promote energy efficiency in buildings over its jurisdiction. Several reasons make this project innovative: first, the certification method has been processed through and verified by a quality international agency, secondly the procedure is assisting financial-incentive policies both on mandatory (European Directive 2002/91/CE) and voluntary basis (Municipality Protocol Ecoabita), finally it allows to obtain eligible credits for avoided emissions that can be negotiated on the CO2 exchange market. With specific reference to Reggio Emilia case, acknowledged the amount of actions, that are normally scheduled in the municipality throughout a year, it has been evaluated the benefit, in terms of environmental improvement, descended from the protocol, also projecting their trend in future years up to 2020 as well, demonstrating the scheduled interventions are fundamental in sought of the achievement of the Kyoto and Copenhagen commitments. The entire procedure has been developed in accordance to the parameters given by UNFCCC for these kinds of analyses and has been recently confirmed to be one of the most accurate international accounting procedure by a survey developed by the scientific committee of the European Project LIFE-LAKS.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2011.05.027&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 8 citations 8 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2011.05.027&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint 2023Embargo end date: 01 Jan 2023Publisher:Elsevier BV Authors: Maomao Hu; Ram Rajagopal; Jacques A. de Chalendar;arXiv: 2304.13175
Building energy flexibility has been increasingly demonstrated as a cost-effective solution to respond to the needs of energy networks, including electric grids and district cooling and heating systems, improving the integration of intermittent renewable energy sources. Adjusting zonal temperature set-points is one of the most promising measures to unlock the energy flexibility potential of central air conditioning systems in complex commercial buildings. However, most existing studies focused on quantifying the energy flexibility on the building level since only building-level energy consumption is normally metered in commercial buildings. This study aims to investigate the impacts of temperature set-point adjustment strategies on zone-level thermal and energy performance by developing a non-intrusive data-driven load disaggregation method (i.e., a virtual zonal power meter). Three university buildings in Northern California were selected to test the proposed load disaggregation method. We found that heterogeneities of energy use and energy flexibility existed across not only buildings but also air handling units (AHUs) and zones. Moreover, a small number of zones accounted for a large amount of energy use and energy flexibility; and the most energy-intensive zones are not necessarily the most energy-flexible zones. For the three tested buildings, the top 30% most energy-intensive zones accounted for around 60% of the total energy use; and the top 30% most energy-flexible zones provided around 80% of the total energy flexibility. The proposed method enables the electric grid or district energy system operators to regard the controlled energy-flexible entities as a fleet of AHUs or zones instead of a fleet of buildings and helps unlock the possibility for targeted demand flexibility strategies that balance zone-by-zone energy reduction with zone-by-zone costs to occupants. 33 pages, 18 figures
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.113339&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen 2 citations 2 popularity Average influence Average impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2023.113339&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Authors: Kijung Kim; Changhyo Yi; Seungil Lee;Abstract A change in the thermal environment of an urban area affects health, living conditions, and energy consumption. In urban planning, urban parks are one of the methods for improving the thermal environment and saving cooling energy. Urban park construction can mitigate temperature, but it also causes urban development by increasing local attractiveness. To achieve efficient energy saving through parks in urban planning, the purpose of this study is to investigate the relationship between building energy consumption and urban characteristics both before and after the construction of an urban park. This study targeted Seoul's Gyeongui line forest, which was recently converted into a linear park on the former railway as an urban regeneration project. We analyzed the relationship between energy consumption and urban characteristics using a regression model, focusing on the changes before and after the construction. In this study, urban characteristics include environment, building physical characteristics, and economic variables. The results show that the construction of the urban park reduced not only temperature but also building energy consumption. The energy reduction effect of the park was limited to a marginal distance. Meanwhile, the urban park construction caused land prices to rise and prompted new development, and this changed the urban characteristics of the area and affected energy consumption. Despite changes in urban characteristics, urban park planning is an effective methods of reducing the energy consumption involved in cooling urban areas. We recommend comprehensive consideration of the urban factors when making park policy to reduce urban temperature and energy consumption.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.03.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 21 citations 21 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.03.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal , Other literature type 2019Embargo end date: 14 Apr 2020Publisher:Elsevier BV Authors: Gupta, Rajat; Bruce-Konuah, Adorkor; Howard, Alastair;Abstract This paper empirically evaluates the extent of energy resilience achieved in a socially-deprived community in Oxford, through deployment of solar photovoltaic (PV) systems and smart batteries (internet enabled and controllable) across a cluster of 82 dwellings (households). The methodological approach comprised dwelling and household surveys, along with high frequency monitoring of household electricity consumption, solar PV generation, battery charge and discharge data. In the monitored households, average daily electricity consumption was found to be positively related with dwelling size, number of occupants and number of appliances used. Although 117 MWh of PV electricity was generated within a year across 74 dwellings, peak generation did not match peak consumption, demonstrating the need for battery storage. Home batteries were found to increase self-consumption of PV electricity and offset grid demand through discharge of stored PV electricity marginally at an average of 6%, depending on the size of the PV system, surplus PV electricity available and size of the battery. Aggregating solar generation and storage at a community level showed that peak grid electricity demand between 17:00 and 19:00 was reduced by 8% through the use of smart batteries across 74 dwellings. In future, a local energy sharing scheme could be developed, wherein not all dwellings would need to have solar PV systems, but rather have internet enabled batteries that could be monitored and controlled virtually.
Energy and Buildings arrow_drop_down Oxford Brookes University: RADARArticle . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADAROxford Brookes University: RADAROther literature type . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADARadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.04.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 56 citations 56 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy and Buildings arrow_drop_down Oxford Brookes University: RADARArticle . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADAROxford Brookes University: RADAROther literature type . 2019License: CC BY NC NDData sources: Oxford Brookes University: RADARadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2019.04.012&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1981Publisher:Elsevier BV Authors: G.B. Varey; Ashley F. Emery; C.J. Kippenhan; D.R. Heerwagen;Abstract A numerical simulation program, based upon a finite difference nodal network, was used to simulate two Los Alamos test cells (one single and one multi-room cell) and a typical residence — all of which were exposed to intense insolation and large changes in ambient weather conditions. For the test cells, the predicted surface and globe temperatures are in good agreement with the measured values and indicate the acceptability of thermal modeling. The program was used to predict the behavior of a residential structure. The process of refining these predictions, guided by observations, led to the development of a stepwise simulation methodology. The insights gained as a result of this interdisciplinary involvement have been stimulating and instructive. The importance of recognizing the differences in the thought processes and the work styles of the several professions has been demonstrated. The most effective simulation methodology was that based upon human comfort, which appeared to be a common perception amongst all the program users.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0378-7788(81)90012-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 9 citations 9 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/0378-7788(81)90012-8&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2014 AustraliaPublisher:Elsevier BV Authors: Hirning, Michael; Isoardi, Gillian; Cowling, Ian;Abstract This study presents the largest-known, investigation on discomfort glare with 493 surveys collected from five green buildings in Brisbane, Australia. The study was conducted on full-time employees, working under their everyday lighting conditions, all of whom had no affiliation with the research institution. The survey consisted of a specially tailored questionnaire to assess potential factors relating to discomfort glare. Luminance maps extracted from high dynamic range (HDR) images were used to capture the luminous environment of the occupants. Occupants who experienced glare on their monitor and/or electric glare were excluded from analysis leaving 419 available surveys. Occupants were more sensitive to glare than any of the tested indices accounted for. A new index, the UGP was developed to take into account the scope of results in the investigation. The index is based on a linear transformation of the UGR to calculate a probability of disturbed persons. However all glare indices had some correlation to discomfort, and statistically there was no difference between the DGI, UGR and CGI. The UGP broadly reflects the demographics of the working population in Australia and the new index is applicable to open plan green buildings.
Queensland Universit... arrow_drop_down Queensland University of Technology: QUT ePrintsArticle . 2014License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2013.11.053&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 109 citations 109 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Queensland Universit... arrow_drop_down Queensland University of Technology: QUT ePrintsArticle . 2014License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2013.11.053&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2009Publisher:Elsevier BV Ewa Wäckelgård; Joakim Widén; Erik Dahlquist; Iana Vassileva; Magdalena Lundh; Kajsa Ellegård;Time-use data, describing in detail the everyday life of household members as high-resolved activity sequences, have a largely unrealized potential of contributing to domestic energy demand modelli ...
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2009.02.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 302 citations 302 popularity Top 1% influence Top 1% impulse Top 1% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2009.02.013&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Ahmad Ihsan Mohd Yassin; Rijalul Fahmi Mustapa; Atiqah Hamizah Mohd Nordin; Nofri Yenita Dahlan;Abstract Energy conservation measures (ECM) through awareness, good housekeeping measures and demand side management are the first step that must be implemented to achieve energy savings in any building. The energy savings from the implemented ECM must be properly quantified to demonstrate its effectiveness and success. Quantifying energy savings using Multiple Linear Regression (MLR) model have been gaining popularity due to its simple approach but its inability to model and predict dynamic behavior that involves non-linearity relationships can be seen as its main drawback. Thus, the objective of this work is twofold, where the first fold is to implement an ECM program in a building and the second fold is to determine the energy saved from the ECM program using Non-Linear autoregressive with Exogenous inputs artificial neural network (NARX-ANN). The ECM program was executed at one floor of a university building. NARX-ANN was used to model the baseline energy consumption and determine the energy savings following the International Performance Measurement and Verification Protocol (IPMVP). A comparison was made between the MLR and the NARX-ANN model where the latter provides higher accuracy in statistical error compared to the MLR model. The energy savings from the awareness program determined by the NARX-ANN model was 170.84 kWh with Mean Square Error and Root Mean Square accuracy of 0.6068 and 0.7790 respectively.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2020.109899&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 29 citations 29 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enbuild.2020.109899&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu