Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Applied Energyarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Applied Energy
Article
License: CC BY NC ND
Data sources: UnpayWall
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Applied Energy
Article . 2019 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Evaluation of the passive pre-chamber ignition concept for future high compression ratio turbocharged spark-ignition engines

Authors: P.J. Martinez-Hernandiz; Ricardo Novella; C. Libert; J. Gomez-Soriano; Jesús Benajes; M. Dabiri;

Evaluation of the passive pre-chamber ignition concept for future high compression ratio turbocharged spark-ignition engines

Abstract

[EN] The pre-chamber ignition concept is an attractive strategy to enable the operation of spark-ignition engines in lean or diluted conditions keeping a suitable combustion process. According to the results the benefits in lean conditions include the combustion process shortening, the improvement of combustion stability and the increase of combustion efficiency by lowering carbon monoxide and hydrocarbons emissions. Thus, the pre-chamber ignition concept, especially in its passive version, arises as a promising alternative for future spark-ignition engines for passenger car applications. In this framework, an experimental investigation has been carried out to evaluate the potential of passive pre-chamber ignition concept in a high compression ratio, turbocharged, port fueled spark-ignition engine, using 95 Research Octane Number gasoline. As a first step, a 1D Wave Action Model was generated to design the pre-chamber geometry taking the fuel available at the start of pre-chamber combustion and the pressure difference between the main chamber and pre-chamber as key parameters. In a second step, these pre-chamber designs were experimentally validated at high load/speed conditions (4500¿rpm, 12.5¿bar Indicated Mean Effective Pressure) and compared with the conventional spark-ignition concept. Experimental results show how the passive pre-chamber concept increases efficiency with good combustion stability and high combustion efficiency in stoichiometric conditions. Nevertheless, maximum lambda attainable with the passive system is similar than that of the conventional spark and much lower compared to the maximum levels reported for the active system. The work has been partially supported by the Spanish Ministerio de Economia y Competitividad through Grant No. TRA2017-89139-C2-1-R.

Keywords

Pre-chamber ignition, MAQUINAS Y MOTORES TERMICOS, EGR dilution, Efficiency and emissions, Spark-ignition engine, Lean burn

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    131
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 1%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 1%
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 67
    download downloads 405
  • 67
    views
    405
    downloads
    Data sourceViewsDownloads
    RiuNet67405
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
131
Top 1%
Top 10%
Top 1%
67
405
Green
hybrid