You have already added 0 works in your ORCID record related to the merged Research product.
You have already added 0 works in your ORCID record related to the merged Research product.
Long-term Behavior, Accuracy and Drift of LI-200 Pyranometers as Radiation Sensors in Rotating Shadowband Irradiometers (RSI)
AbstractRotating Shadowband Irradiometers (RSI) are frequently used for solar resource assessment at remote sites due to their significantly higher robustness for soiling, their lower power and maintenance requirements and their cheaper acquisition and operation in contrast to pyrheliometer on tracker systems. The primordial lower accuracy of their photodiode sensor, usually a LI-200 pyranometer from LI-COR Inc., is mainly caused by restrictions of their spectral sensitivity and temperature dependence. However accuracy is notably increased by application of corrections to the raw sensor response. Thus, finally a coincidence of DNI measurements from RSIs with high-precision pyrheliometer measurements within 15W/m2 (root mean square deviation for 10min averages) for actual values, less than 3% for daily DNI and within approximately 1.5% of the monthly and annual sum is reached. Within this contribution, the long-term behavior of the LI-COR sensor is examined with regard to the drift of the photodiode sensitivity. This is analyzed from recalibrations of 30 sensors after one to four years and from long-term studies lasting from one to several years. If a significant drift appears, the corresponding uncertainties can be reduced through recalculation of the previous measurement data for the total measurement campaign. Furthermore, studies about the coincidence and deviation of the responses for global, diffuse and direct irradiance of RSI measurements between several individual RSIs and to reference measurements from high-precision thermopiles are presented for different time resolutions.
- German Aerospace Center Germany
RSP, accuracy, drift, Qualifizierung, pyranometer, rotating shadowband irradiometers, DNI, Energy(all), photodiode, irradiation measurement, Rotating Shadowband Irradiometer, RSI
RSP, accuracy, drift, Qualifizierung, pyranometer, rotating shadowband irradiometers, DNI, Energy(all), photodiode, irradiation measurement, Rotating Shadowband Irradiometer, RSI
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).19 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Top 10% impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%