Shallow geothermal energy potential for heating and cooling of buildings with regeneration under climate change scenarios

arXiv: 2112.01183
Shallow geothermal energy potential for heating and cooling of buildings with regeneration under climate change scenarios
Shallow ground-source heat pumps (GSHPs) are a promising technology for contributing to the decarbonisation of the energy sector. In heating-dominated climates, the combined use of GSHPs for both heating and cooling increases their technical potential, defined as the maximum energy that can be exchanged with the ground, as the re-injection of excess heat from space cooling leads to a seasonal regeneration of the ground. This paper proposes a new approach to quantify the technical potential of GSHPs, accounting for effects of seasonal regeneration, and to estimate the useful energy to supply building energy demands at regional scale. The useful energy is obtained for direct heat exchange and for district heating and cooling (DHC) under several scenarios for climate change and market penetration levels of cooling systems. The case study in western Switzerland suggests that seasonal regeneration allows for annual maximum heat extraction densities above 300 kWh/m$^2$ at heat injection densities above 330 kWh/m$^2$. Results also show that GSHPs may cover up to 55% of heating demand while covering 57% of service-sector cooling demand for individual GSHPs in 2050, which increases to around 85% with DHC. The regional-scale results may serve to inform decision making on strategic areas for installing GSHPs.
Walch and Li contributed equally. Revision submitted to Energy
- Middlesex University United Kingdom
- University of Geneva Switzerland
- École Polytechnique Fédérale de Lausanne EPFL Switzerland
- University College London United Kingdom
- University of London United Kingdom
690, design, exchangers, Systems and Control (eess.SY), Shallow geothermal energy, Electrical Engineering and Systems Science - Systems and Control, climate change scenarios, district heating and cooling, District heating and cooling, FOS: Electrical engineering, electronic engineering, information engineering, Potential estimation, Climate change scenarios, areas, pump systems, methodology, demand, seasonal regeneration, Seasonal regeneration, potential estimation, shallow geothermal energy, feasibility
690, design, exchangers, Systems and Control (eess.SY), Shallow geothermal energy, Electrical Engineering and Systems Science - Systems and Control, climate change scenarios, district heating and cooling, District heating and cooling, FOS: Electrical engineering, electronic engineering, information engineering, Potential estimation, Climate change scenarios, areas, pump systems, methodology, demand, seasonal regeneration, Seasonal regeneration, potential estimation, shallow geothermal energy, feasibility
1 Research products, page 1 of 1
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).41 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Top 10% impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 1%