
You have already added 0 works in your ORCID record related to the merged Research product.
You have already added 0 works in your ORCID record related to the merged Research product.
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>
Is multidetector computed tomography a suitable alternative to MR imaging for the assessment of myocardial necrosis after alcohol septal ablation?

pmid: 21794940
To compare magnetic resonance (MR) imaging and multidetector computed tomography (MDCT) for the assessment of myocardial infarction (MI) after alcohol septal ablation (ASA).Ten patients (mean age, 60 years ± 16) were examined with both MDCT and 1.5-T MR imaging performed 10 minutes after injection, within 3 days after ASA. Half of them had a temporary pacemaker (PM) during MDCT examination. Global image quality (IQ) and localization of MI were noticed on both MDCT and MR images. Volumes of MI, contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) were also calculated. ASA effectiveness was evaluated by echocardiography immediately and 3 months after procedure.Global IQ was considered adequate for both procedures. In 8 patients, MI reached the basal part of the septum on both MDCT and MR images. The 2 remaining patients exhibited sparing of the basal septum on MDCT and MR images. Volumes of MI were within the same range with the 2 techniques (MDCT: 22.1 ± 8.8 mL; MR imaging: 23.8 ± 9.4 mL) and correlated well each other (R(2)=0.85, p<0.002). The 2 patients with sparing of the basal interventricular septum had persistent gradient on echocardiography 3 months after ASA, suggesting failure of the procedure. The volumes of MI didn't correlate with the reduction of pressure gradient on echocardiography 3 months after ASA (R(2)=0.02, p<0.05).Evaluation of post ASA MI is feasible with MDCT by comparison with MR imaging. MDCT might serve as an alternative imaging method in case of PM implantation.
Ablation Techniques, Adult, Aged, 80 and over, Male, Ethanol, Myocardium, Myocardial Infarction, Cardiomyopathy, Hypertrophic, Middle Aged, Magnetic Resonance Imaging, Necrosis, Multidetector Computed Tomography, Heart Septum, Feasibility Studies, Humans, Female, Prospective Studies, Aged
Ablation Techniques, Adult, Aged, 80 and over, Male, Ethanol, Myocardium, Myocardial Infarction, Cardiomyopathy, Hypertrophic, Middle Aged, Magnetic Resonance Imaging, Necrosis, Multidetector Computed Tomography, Heart Septum, Feasibility Studies, Humans, Female, Prospective Studies, Aged
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).6 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Average influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Top 10% impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%
