Control and protection sequence for recovery and reconfiguration of an offshore integrated MMC multi-terminal HVDC system under DC faults

AbstractA comprehensive process of the control and protection against a DC fault in a voltage source converter (VSC) based high-voltage direct current (HVDC) system typically includes fault detection, fault isolation and system recovery. Regarding an offshore wind farm (OWF) integrated modular multilevel converter (MMC) based multi-terminal HVDC (MTDC) system with two control paradigms, i.e. master-slave control and droop control under DC faults, this paper presents the fault isolation, including the isolation of the faulted line section, with detailed control and protection sequence, which would be useful for practical engineering. The control and protection sequence at the system recovery/reconfiguration phase is comprehensively investigated, which includes: (1) when to start the recovery/reconfiguration control; (2) the sequence between deblocking the MMCs and reclosing the AC circuit breakers (AC CBs); and (3) the recovery sequence of each HVDC terminal. Based on the analysis of the system characteristics, a preferred recovery/reconfiguration scheme is proposed. Simulation results on the real-time digital simulator (RTDS) validate the proposed scheme and demonstrate the advantages through comparison with a different recovery sequence. The impact of transient and permanent DC faults on the system recovery/reconfiguration control is discussed. In addition, the recovery/reconfiguration control of the MTDC in radial and meshed topologies is compared and demonstrated. Based on the analytical and simulation studies, a general guideline on the recovery/reconfiguration control of MMC MTDC systems is proposed.
- Nanjing University of Science and Technology China (People's Republic of)
- National Grid (United States) United States
- National Grid (United Kingdom) United Kingdom
- Southeast University China (People's Republic of)
- Nanjing University of Science and Technology China (People's Republic of)
Control and protection sequence, Modular multilevel converter (MMC), Droop control, DC fault, Recovery and reconfiguration sequence, Multi-terminal HVDC (MTDC), Master-slave control, Energy Engineering and Power Technology, Electrical and Electronic Engineering, Offshore wind farm (OWF)
Control and protection sequence, Modular multilevel converter (MMC), Droop control, DC fault, Recovery and reconfiguration sequence, Multi-terminal HVDC (MTDC), Master-slave control, Energy Engineering and Power Technology, Electrical and Electronic Engineering, Offshore wind farm (OWF)
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).33 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Top 10% impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%