image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Renewable Energyarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Renewable Energy
Article . 2017 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
versions View all 1 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

A novel adsorption module with fiber heat exchangers: Performance analysis based on driving temperature differences

Authors: Ursula Wittstadt; Gerrit Füldner; Eric Laurenz; Alexander Warlo; André Große; Ralph Herrmann; Lena Schnabel; +1 Authors

A novel adsorption module with fiber heat exchangers: Performance analysis based on driving temperature differences

Abstract

Abstract A main focus of recent R&D on adsorption modules for thermally driven heat pumps and chillers has been to enhance the volume specific power output while maintaining a reasonable coefficient of performance (COP). An adsorption module using a new type of heat exchanger based on aluminum sintered metal fiber structures brazed on flat fluid channels has been developed. The heat exchangers for adsorber/desorber and evaporator/condenser are identically constructed. The adsorption heat exchanger is coated with a silico-alumino phosphate (SAPO-34) by a partial support transformation direct crystallization (PST) [1]. Both components are placed in a vacuum tight housing using a valve-free configuration. Water is used as adsorptive. The experimental characterization of the module shows a high volume specific power (up to 82 W/litre module for cooling, 320 W/litre for heating). Although no heat is recovered between ad- and desorption cycle, a COP of almost 0.4 is reached for cooling and 1.4 for heating. Driving temperature differences are defined for the analysis of the heat exchanger performance. The evaporator/condenser shows extremely good performance with about 240 W/K specific evaporation power per litre of heat exchanger, while the adsorber is limiting the module performance.