Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao RE.PUBLIC@POLIMI Res...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
https://doi.org/10.1049/cp.201...
Conference object . 2014 . Peer-reviewed
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Harmonic compensation with active front-end converters based only on grid voltage measurements

Authors: D'Arco, S.; PIEGARI, LUIGI; Tricoli, P.;

Harmonic compensation with active front-end converters based only on grid voltage measurements

Abstract

In the recent years, there has been a considerable increment of diffused generators connected to distribution grids by means of power converters. These converters operate frequently below their rated power due to the fluctuation of the power generated by the renewable sources. In this scenario, power electronics interfaces could be also used as active harmonic compensators for other converters or distorting loads. Typically, these converters do not have information on other loads or on the level of grid current distortion. For this reason, this paper presents a new control algorithm for the grid harmonics compensation that relies only on the measurement of the voltage at the point of connection of the power converter. The reference of the compensating current is calculated from the harmonic content of the voltage in a reference frame synchronous with the grid voltage. Simulation results carried out on a sample distribution network with linear and nonlinear loads show that the proposed method does not require the knowledge of the harmonic current either of the grid or of the load and it is suitable when the distorting loads are unknown.

Country
Italy
Keywords

Active filters; Distributed generation; Harmonic compensation; Electrical and Electronic Engineering, Elettrici

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    3
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
3
Average
Average
Average