Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ IEEE Accessarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
IEEE Access
Article . 2021 . Peer-reviewed
License: CC BY
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
IEEE Access
Article
License: CC BY NC ND
Data sources: UnpayWall
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
IEEE Access
Article . 2021
Data sources: DOAJ
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 3 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Framework to Develop Time- and Voltage-Dependent Building Load Profiles Using Polynomial Load Models

Authors: Andrew Parker; Mhd Anas Alkrch; Kevin James; Ahmad Almaghrebi; Mahmoud A. Alahmad;

Framework to Develop Time- and Voltage-Dependent Building Load Profiles Using Polynomial Load Models

Abstract

The power consumption of buildings over the course of each minute, hour, day and season plays a major role in how this load influences the Electric Power System voltage and frequency, and vice versa. This consumption is based on the building’s load component types, efficiencies, and how they consume power and react to changes in real time. Due to this complexity, standard full-building load models are typically voltage-invariant. This paper proposes a novel framework to transform these voltage-invariant building load models into fully time- and voltage-dependent load profiles using available data on the voltage sensitivity of individual load components. While a voltage-dependent building model could theoretically be generated from static load models of every component in a building, this approach faces two challenges: first, load models representing all load components are impractical to develop for all possible load component types; second, building energy consumption is never measured or modeled at the individual component level. The proposed framework compiles available component data in the form of static ZIP load model parameters, and maps them into the end use categories utilized by standard building modeling programs. The voltage sensitivity of each end use category is then bounded by the extrema of the component models within it. This framework is applied to a load profile case study representing the aggregate U.S. residential building stock. In addition to the minimum/maximum conditions, a load profile based on typical load composition and weighted ZIP parameters is generated for the same building stock. The results show that for a 10% drop in voltage, using the least sensitive ZIP parameters, active power is expected to be 3% to 14% lower than nominal, depending on the season and time of day. Using the most sensitive ZIP parameters, the active power is expected to be 9% to 20% lower than nominal, also depending on the season and time of day.

Country
United States
Keywords

330, Environmental Design, load profile, Architectural Engineering, ZIP parameters, 620, TK1-9971, energy consumption, load component, Electrical engineering. Electronics. Nuclear engineering, Construction Engineering, Other Engineering, Load model

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Top 10%
Average
Average
gold