Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao https://doi.org/10.1...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
https://doi.org/10.1109/icet48...
Conference object . 2019 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
versions View all 1 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Design and Investigation of FRT Schemes for Three-Phase Grid-Tied PV System

Authors: Saiful Islam; Muhammad Ishfaq; Kamran Zeb; Waqar Uddin; Imran Khan; Zahid Ullah; Hee-Je Kim;

Design and Investigation of FRT Schemes for Three-Phase Grid-Tied PV System

Abstract

This paper presents a newly designed fault-ride-through (FRT) scheme i.e. bridge-type fault-current limiter (BFCL) for Grid-Tied photovoltaic system (PVS) to optimize unbalance fault variables. A 100 kW three-phase Grid-Tied MATLAB/Simulink model is used to analyze the system response during unbalance conditions. The simulation results of designed FRT scheme are critically compared with conventionally adopted FRT scheme i.e. crowbar circuitry. However, for inverter control proportional integrator (PI) controller is used. Moreover, the analysis is carried out for faults at point of common-coupling (PCC) as well as 5-km away from PCC. The obtained simulated results of PI controller with well-designed FRT scheme authenticates stable, minimum oscillation, ripples free, robust and fast performance for unbalance fault variables as compared to previous work.

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Top 10%
Average
Average