Direct Lightning Strikes to Test Power Distribution Lines—Part II: Measured and Modeled Current Division Among Multiple Arresters and Grounds

The division of return stroke current among the arresters and groundings of two unenergized test distribution lines, one horizontally configured and the other vertically configured, was studied at the International Center for Lightning Research and Testing in Florida. The division of return stroke currents for the vertically configured line was initially similar to the division on the horizontally configured line: at the time the return stroke current reached peak value (after one microsecond, or so) the two closest arresters/grounds on both lines passed about 90% of the total current. However, the time during which the return stroke current flowed primarily through the closest arresters to the neutral conductor was significantly shorter on the vertically configured line. On that line, the arrester current was about equally divided among all four arresters after several tens of microseconds. The arrester current division as a function of time measured on the vertical line was successfully modeled using the published VI-characteristic, while the division on the horizontal line after some tens of microseconds was only successfully modeled if the residual voltage of the two arresters closest to the current injection point was reduced by 20%. Based on the triggered lightning current division observed on our line, the minimum energy absorbed in each of the two arresters closest to the strike point during a typical natural first stroke is estimated to be 40 kJ.
- University of Florida United States
- Florida Southern College United States
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).25 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Top 10% impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%