
You have already added 0 works in your ORCID record related to the merged Research product.
You have already added 0 works in your ORCID record related to the merged Research product.
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>
Retrofitting a Fifth Generation District Heating and Cooling Network for Heating and Cooling in a UK Hospital Campus

Retrofitting a Fifth Generation District Heating and Cooling Network for Heating and Cooling in a UK Hospital Campus
There is an increasingly rich literature on the decarbonisation of heat and the evolution of heat networks. This paper investigates whether a novel fifth Generation District Heating and Cooling Network (5GDHC) could be retrofitted to an existing National Health Service (NHS) hospital campus for the purpose of heating and cooling. The building load was simulated and input into a custom-written script to carry out a series of parametric studies and optimise design options. The model was calibrated against site data available from hospital facilities management. The research found that it is feasible to use a 5GDHC consisting of a large single mass of water to utilise inter-seasonal thermal storage. A natural water resource such as an aquifer was not required. The model tested sizing options and found that larger thermal storage, heat pumps and chillers reduce operating costs and improve flexibility. The paper closes with a discussion of the practical factors in retrofitting 5GDHC networks to a densely occupied and highly constrained campus environment. The findings are novel in further describing the circumstances for which 5GDHC networks are suitable.
- London South Bank University United Kingdom
- London South Bank University United Kingdom
Building construction, heat network, retrofit, decarbonisation of heat, 5GDHC, TH1-9745
Building construction, heat network, retrofit, decarbonisation of heat, 5GDHC, TH1-9745
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).0 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Average influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Average
