Analysis of Metal Oxide Varistor Arresters for Protection of Multiconductor Transmission Lines Using Unconditionally-Stable Crank–Nicolson FDTD

doi: 10.3390/en13082112
handle: 11588/867040 , 11573/1401719
Surge arresters may represent an efficient choice for limiting lightning surge effects, significantly reducing the outage rate of power lines. The present work firstly presents an efficient numerical approach suitable for insulation coordination studies based on an implicit Crank–Nicolson finite difference time domain method; then, the IEEE recommended surge arrester model is reviewed and implemented by means of a local implicit scheme, based on a set of non-linear equations, that are recast in a suitable form for efficient solution. The model is proven to ensure robustness and second-order accuracy. The implementation of the arrester model in the implicit Crank–Nicolson scheme represents the added value brought by the present study. Indeed, its preserved stability for larger time steps allows reducing running time by more than 60 % compared to the well-known finite difference time domain method based on the explicit leap-frog scheme. The reduced computation time allows faster repeated solutions, which need to be looked for on assessing the lightning performance (randomly changing, parameters such as peak current, rise time, tail time, location of the vertical leader channel, phase conductor voltages, footing resistance, insulator strength, etc. would need to be changed thousands of times).
- University of Lisbon Portugal
- University Federico II of Naples Italy
- Instituto de Telecomunicações Portugal
- Sapienza University of Rome Italy
- Instituto Superior de Espinho Portugal
Transmission lines, Technology, Protection, transmission lines, FDTD, T, FDTD; metal oxide varistors arresters; protection; transmission lines, protection, Metal Oxide Varistors Arresters, FDTD; Metal Oxide Varistors Arresters; Protection; Transmission lines, FDTD; Metal Oxide Varistors Arresters; transmission lines; protection
Transmission lines, Technology, Protection, transmission lines, FDTD, T, FDTD; metal oxide varistors arresters; protection; transmission lines, protection, Metal Oxide Varistors Arresters, FDTD; Metal Oxide Varistors Arresters; Protection; Transmission lines, FDTD; Metal Oxide Varistors Arresters; transmission lines; protection
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).10 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%