
You have already added 0 works in your ORCID record related to the merged Research product.
You have already added 0 works in your ORCID record related to the merged Research product.
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>
Evaluation of the Current Shunt Influence on the Determined Wideband Accuracy of Inductive Current Transformers

doi: 10.3390/en15186840
This manuscript presents performed laboratory studies and the analysis of the impact of current shunt values used in the differential connection on the wideband metrological performance of inductive current transformers. Moreover, a comparison of the accuracy of wideband and 50 Hz-type inductive current transformers in the specified frequency range from 50 Hz to 5 kHz is presented. The main factor which may influence the wideband accuracy of inductive current transformers is the phenomenon of self-generation. This causes rapid changes in the accuracy, and simultaneously causes the most positive and the most negative values of current error and phase displacement. To evaluate the metrological performance in the differential measurement setup for higher harmonics of the distorted current, a digital acquisition board was used. Obtained results show that if proper values of current shunt resistance are chosen, such devices may be used to evaluate the wideband accuracy of inductive current transformers. The results indicate that the typical units designed for the transformation of sinusoidal current with a frequency of 50 Hz can achieve a comparable metrological performance to that of the wideband inductive current transformer.
higher harmonics, Technology, current error, accuracy, current transformer, T, distorted current; current transformer; accuracy; higher harmonics; phase displacement; current error; differential circuit; wideband instrument transformer, phase displacement, distorted current
higher harmonics, Technology, current error, accuracy, current transformer, T, distorted current; current transformer; accuracy; higher harmonics; phase displacement; current error; differential circuit; wideband instrument transformer, phase displacement, distorted current
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).2 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Average
