Detection of Cavitation in a Centrifugal Pump-as-Turbine Using Time-Domain-Based Analysis of Vibration Signals

doi: 10.3390/en17112598
Pumps-as-Turbines (PATs) are increasingly used in micro-hydropower applications due to their cost competitiveness that is brought about by lower acquisition, design, operation, and maintenance costs. Despite these, limited research exists that investigates PAT failures. Notably, there is a literature gap concerning cavitation in PATs. As such, this study proposes an improvement to the deviation from the normal distribution (DND) technique to facilitate application in PAT cavitation detection. Probability density functions of vibration signals collected during operation at design speed and various cavitation states are developed and the DND computed using two approaches, i.e., the use of baseline data and the original method, for comparison purposes. Normal probability plots are presented to depict suitability of the two approaches in quantifying the DND. Results show higher deviation when using baseline data, hence, improved detection capabilities with amplification of the slope of the trend line under cavitating conditions when using the proposed DND approach. The proposed method also allows for establishing clear alarm limits for the condition monitoring of PATs in practice. Moreover, the proposed method is validated by application at various PAT operating speeds and cavitation states. The proposed method is found to be responsive, reliable, and independent from operating speed.
- Trinity College Dublin Ireland
Technology, cavitation detection, condition monitoring, T, time domain analysis, health monitoring, pumps-as-turbines, vibration analysis
Technology, cavitation detection, condition monitoring, T, time domain analysis, health monitoring, pumps-as-turbines, vibration analysis
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).0 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Average influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Average