Surface Environment and Energy Density Effects on the Detection and Disinfection of Microorganisms Using a Portable Instrument

Real-time detection and disinfection of foodborne pathogens are important for preventing foodborne outbreaks and for maintaining a safe environment for consumers. There are numerous methods for the disinfection of hazardous organisms, including heat treatment, chemical reaction, filtration, and irradiation. This report evaluated a portable instrument to validate its simultaneous detection and disinfection capability in typical laboratory situations. In this challenging study, three gram-negative and two gram-positive microorganisms were used. For the detection of contamination, inoculations of various concentrations were dispensed on three different surface types to estimate the performance for minimum-detectable cell concentration. Inoculations higher than 103~104 CFU/mm2 and 0.15 mm of detectable contaminant size were estimated to generate a sufficient level of fluorescence signal. The evaluation of disinfection efficacy was conducted on three distinct types of surfaces, with the energy density of UVC light (275-nm) ranging from 4.5 to 22.5 mJ/cm2 and the exposure time varying from 1 to 5 s. The study determined the optimal energy dose for each of the microorganisms species. In addition, surface characteristics may also be an important factor that results in different inactivation efficacy. These results demonstrate that the proposed portable device could serve as an in-field detection and disinfection unit in various environments, and provide a more efficient and user-friendly way of performing disinfection on large surface areas.
- Purdue University West Lafayette United States
- TRUSTEES OF PURDUE UNIVERSITY United States
- Purdue University West Lafayette United States
- School of Mechanical Engineering Purdue University United States
- TRUSTEES OF PURDUE UNIVERSITY United States
Chemical technology, TP1-1185, contamination detection, portable device, Article, Disease Outbreaks, Disinfection, Physical Phenomena, microorganisms, Drug Contamination, disinfection, energy density, Filtration
Chemical technology, TP1-1185, contamination detection, portable device, Article, Disease Outbreaks, Disinfection, Physical Phenomena, microorganisms, Drug Contamination, disinfection, energy density, Filtration
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).3 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Average influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Average