Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Recolector de Cienci...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Compensación de energía reactiva en un edificio con generación fotovoltaica

Authors: Souto Lázaro, Alejandro;

Compensación de energía reactiva en un edificio con generación fotovoltaica

Abstract

En un sistema de corriente alterna, típico en la mayoría de las instalaciones eléctricas, se consumen dos tipos de energía: la energía activa y la energía reactiva. La energía activa es la que realiza un trabajo útil, mientras que la energía reactiva no proporciona ninguno. De todos modos, la energía reactiva es esencial para el correcto funcionamiento de algunos equipos eléctricos como motores o transformadores, entre otros. No obstante, un exceso de energía reactiva en una instalación eléctrica puede desencadenar varios problemas importantes, entre ellos la disminución del factor de potencia. Un bajo factor de potencia puede resultar en pérdidas de capacidad en las líneas de distribución y, por lo tanto, en la necesidad de sobredimensionar algunos equipos o cableado. Por ello, las comercializadoras eléctricas imponen una penalización económica a aquellas instalaciones con un bajo factor de potencia. Los sistemas de generación solar fotovoltaica son conocidos por ser fuentes de energía limpia, pero su integración en las instalaciones eléctricas puede generar problemas relacionados con el factor de potencia. El objetivo de este proyecto es analizar la problemática del exceso de energía reactiva en las instalaciones eléctricas, evaluar el impacto que un sistema de generación solar fotovoltaica puede tener sobre el factor de potencia y cuantificar las penalizaciones económicas que se le pueden asociar. Finalmente, se realizan dos estudios en los que se compensa el exceso de energía reactiva en dos escenarios diferentes: uno sin sistema de generación fotovoltaica y otro con dicho sistema integrado.

En un sistema de corrent altern, típic a la majoria de les instal·lacions elèctriques, es consumeixen dos tipus d'energia: l'energia activa i l'energia reactiva. L'energia activa és la que fa un treball útil, mentre que l'energia reactiva no en proporciona cap. De tota manera, l'energia reactiva és essencial per al funcionament correcte d'alguns equips elèctrics com ara motors o transformadors, entre d'altres. No obstant això, un excés d'energia reactiva en una instal·lació elèctrica pot desencadenar diversos problemes importants, entre ells la disminució del factor de potència. Un baix factor de potència pot resultar en pèrdues de potència a les línies de distribució i, per tant, la necessitat de sobredimensionar alguns equips o cablejat. Per això, les comercialitzadores elèctriques imposen una penalització econòmica a les instal·lacions amb un baix factor de potència. Els sistemes de generació solar fotovoltaica són coneguts perquè són fonts d'energia neta, però la seva integració a les instal·lacions elèctriques pot generar problemes relacionats amb el factor de potència. L'objectiu d'aquest projecte és analitzar la problemàtica de l'excés d'energia reactiva a les instal·lacions elèctriques, avaluar l'impacte que pot tenir un sistema de generació solar fotovoltaica sobre el factor de potència i quantificar les penalitzacions econòmiques que se li poden associar. Finalment, es fan dos estudis en què es compensa l'excés d'energia reactiva en dos escenaris diferents: un sense sistema de generació fotovoltaica i un altre amb aquest sistema integrat.

In an alternating current system, typical in most electrical installations, two types of energy are consumed: active energy and reactive energy. Active energy is the one that performs useful work, while reactive energy does not provide any. However, reactive energy is essential for the proper functioning of certain electrical equipment such as motors or transformers, among others. Nevertheless, an excess of reactive energy in an electrical installation can lead to various significant issues, including a reduction in the power factor. A low power factor can result in power losses in distribution lines and, therefore, the need to oversize certain equipment or wiring. For this reason, electric utilities impose economic penalties on installations with a low power factor. Solar photovoltaic generation systems are known for being sources of clean energy, but their integration into electrical installations can create issues related to the power factor. The objective of this project is to analyze the problem of excess reactive energy in electrical installations, evaluate the impact that a solar photovoltaic generation system can have on the power factor, and quantify the associated economic penalties. Finally, two studies are conducted where the excess reactive energy is compensated in two different scenarios: one without a photovoltaic generation system and another with the system integrated.

Country
Spain
Keywords

generación solar fotovoltaica, Eficiencia energética, Electric wiring, Energy conservation, Photovoltaic power generation, 530, Electric batteries, batería de condensadores, 004, Estalvi d'energia, Àrees temàtiques de la UPC::Energies, Bateries elèctriques, Instal·lacions elèctriques, factor de potencia, compensación de energía reactiva, Energia solar fotovoltaica

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 41
    download downloads 16
  • 41
    views
    16
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
41
16
Green
Related to Research communities
Energy Research