- home
- Advanced Search
- Energy Research
- Open Access
- US
- EU
- Applied Energy
- Energy Research
- Open Access
- US
- EU
- Applied Energy
description Publicationkeyboard_double_arrow_right Article , Journal 2021 China (People's Republic of), China (People's Republic of), China (People's Republic of), United StatesPublisher:Elsevier BV Han Li; Zhe Wang; Tianzhen Hong; Andrew Parker; Monica Neukomm;The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. The commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116721&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 36 citations 36 popularity Top 10% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116721&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 United KingdomPublisher:Elsevier BV Funded by:UKRI | Heat supply through Solar..., EC | H-DisNetUKRI| Heat supply through Solar Thermochemical Residential Seasonal Storage (Heat-STRESS) ,EC| H-DisNetAuthors: Giampieri, Alessandro; Ma, Zhiwei; Smallbone, Andrew; Roskilly, Anthony Paul;Abstract In an effort to minimise electricity consumption and greenhouse gases emissions, the heating, ventilation and air-conditioning sector has focused its attention on developing alternative solutions to electrically-driven vapour-compression cooling. Liquid desiccant air-conditioning systems represent an energy-efficient and more environmentally friendly alternative technology for dehumidification and cooling, particularly in those cases with high latent loads to maintain indoor air quality and comfort conditions. This technology is considered particularly efficient in hot and humid climates. As a matter of fact, the choice of the desiccant solution influences the overall performance of the system. The current paper reviews the working principle of liquid desiccant systems, focusing on the thermodynamic properties of the desiccant solutions and describes an evaluation of the reference thermodynamic properties of different desiccant solutions to identify which thermodynamic, physical, transport property influences the liquid desiccant process and to what extent. The comparison of these thermodynamic properties for the commonly used desiccants is conducted to estimate which fluid could perform most favourably in the system. The economic factors and the effect of different applications and climatic conditions on the system performance are also described. The paper is intended to be the first step in the evaluation of alternative desiccant fluids able to overcome the problems related to the use of the common desiccant solutions, such as crystallization and corrosion to metals. Ionic liquids seem a promising alternative working fluid in liquid desiccant air-conditioning systems and their characteristics and cost are discussed.
Durham University: D... arrow_drop_down Durham University: Durham Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://dro.dur.ac.uk/29398/Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.03.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 92 citations 92 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Durham University: D... arrow_drop_down Durham University: Durham Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://dro.dur.ac.uk/29398/Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.03.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 CroatiaPublisher:Elsevier BV David Vuilleumier; Ivan Taritas; Benjamin Wolk; Darko Kozarac; Samveg Saxena; Robert W. Dibble;Abstract Advanced combustion engine (ACE) research is typically carried out on single-cylinder research engines. These engines are designed to tightly control fueling and conditions at intake valve closure (IVC) and to precisely measure in-cylinder conditions and emissions. However, to be able to measure and control engine operation so precisely, these research engines typically do not feature intake and exhaust tracts that resemble those in production engines, specifically in regards to turbomachinery, heat exchangers, and exhaust gas recirculation (EGR) systems. For this reason, these research engines are effective for understanding in-cylinder combustion parameters such as heat release rate, burn duration, combustion efficiency, pollutant formation, and exhaust valve opening (EVO) conditions. This paper applies high fidelity simulations to determine the feasibility of achieving a chosen single cylinder engine operating point on a production type homogeneous charge compression ignition (HCCI) engine, using a partial fuel stratification (PFS) strategy. To accomplish this, a Converge 3 dimensional (3D) – computational fluid dynamics (CFD) model of the experimental combustion chamber and intake and exhaust runners was created to simulate the experimental engine. This model was used to simulate an operating point achieved experimentally, as well as to determine the sensitivity of the operating point to variations in intake pressure, intake temperature, injection timing, injected mass, and EGR fraction. The results from these simulations were fed into a 1-dimensional engine simulation created in AVL Boost, featuring production-type intake and exhaust systems, including turbomachinery and heat exchangers necessary to create the required IVC conditions. This full engine simulation was used to assess the cycle efficiency of the engine at the experimental operating condition, and to assess whether changes to this operating point in intake temperature, intake pressure, direct injection timing, or fueling are beneficial to the cycle efficiency and engine-out emissions. In addition, the sensitivity of promising engine operating points to injection timing and injection mass are determined to evaluate the potential stability of these operating points.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.05.043&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 8 citations 8 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.05.043&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 BelgiumPublisher:Elsevier BV Funded by:EC | VADEMECOM, EC | CLEAN-GasEC| VADEMECOM ,EC| CLEAN-GasAlberto Cuoci; Zhiyi Li; Marco Ferrarotti; Marco Ferrarotti; Alessandro Parente;Abstract The present work focuses on the numerical simulation of Moderate or Intense Low oxygen Dilution combustion condition, using the Partially-Stirred Reactor model for turbulence-chemistry interactions. The Partially-Stirred Reactor model assumes that reactions are confined in a specific region of the computational cell, whose mass fraction depends both on the mixing and the chemical time scales. Therefore, the appropriate choice of mixing and chemical time scales becomes crucial to ensure the accuracy of the numerical simulation prediction. Results show that the most appropriate choice for mixing time scale in Moderate or Intense Low oxygen Dilution combustion regime is to use a dynamic evaluation, in which the ratio between the variance of mixture fraction and its dissipation rate is adopted, rather than global estimations based on Kolmogorov or integral mixing scales. This is supported by the validation of the numerical results against experimental profiles of temperature and species mass fractions, available from measurements on the Adelaide Jet in Hot Co-flow burner. Different approaches for chemical time scale evaluation are also compared, using the species formation rates, the reaction rates and the eigenvalues of the formation rate Jacobian matrix. Different co-flow oxygen dilution levels and Reynolds numbers are considered in the validation work, to evaluate the applicability of Partially-Stirred Reactor approach over a wide range of operating conditions. Moreover, the influence of specifying uniform and non-uniform boundary conditions for the chemical scalars is assessed. The present work sheds light on the key mechanisms of turbulence-chemistry interactions in advanced combustion regimes. At the same time, it provides essential information to advance the predictive nature of computational tools used by scientists and engineers, to support the development of new technologies.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.04.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 54 citations 54 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.04.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Funded by:EC | sEEnergiesEC| sEEnergiesAuthors: Meunier, Simon; Protopapadaki, Christina; Baetens, Ruben; Saelens, Dirk;Abstract Integrating low-carbon technologies (e.g. heat pumps, photovoltaic systems) in buildings influences the stability of the low-voltage grid, which therefore often requires to be reinforced. This article proposes a techno-economic methodology to identify the reinforcements needed to maintain grid stability at the lowest life-cycle cost. Novel contributions include the consideration of three-phase connection of low-carbon technologies as a reinforcement option and the fact that we study to what extent grid reinforcements can mitigate voltage unbalance issues. Additionally, to reduce computing time, a dummy island approach is used, whereby one feeder is modelled in detail and the remainder of the distribution island is represented by an aggregated load. Finally, random repetitions are proposed, to consider uncertainties related to building properties, occupants and the location of low-carbon technologies in the feeders. The methodology is applied to investigate the integration of heat pumps and photovoltaic systems in typical Belgian rural and urban grids. For the rural grid, heat pumps may lead to significant reinforcement costs (up to 1230 €/dwelling), mainly due to voltage stability problems. For the urban grid, heat pump and photovoltaic integration causes low reinforcement cost (
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.117057&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 15 citations 15 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.117057&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Publicly fundedFunded by:EC | ATBESTEC| ATBESTAuthors: Jerry D. Murphy; M.A. Voelklein; Davis Rusmanis;Abstract This study investigated in-situ and ex-situ biological methanation strategies for biogas upgrading potential. The addition and circulation of hydrogen with a ceramic gas diffuser unit revealed positive effects on the methanogenic process. A short-term maximum methane productivity of 2.5 L CH4 per L reactor volume per day (LVR−1 d−1) was obtained in-situ. Adverse effects of elevated dissolved hydrogen concentrations on acetogenesis became evident. Ex-situ methanation in a reactor subjected to gas recirculation for recurrent 24 h periods achieved methane formation rates of 3.7 L CH4 LVR−1 d−1. A biomethane with methane concentrations in excess of 96% successfully demonstrated the potential for gas grid injection. A theoretic model supplying gases continuously into a sequential ex-situ reactor system and steadily displacing the upgraded biogas confirmed similar methane formation performance and was advanced to a full-scale concept. Gas conversion efficiency of 95% producing biomethane at 85% methane content was attained. A hybrid model, where an in-situ grass digester is followed by an ex-situ reactor, is proposed as a novel upgrading strategy.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.11.006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 131 citations 131 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.11.006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 United StatesPublisher:Elsevier BV Zhenyuan Yin; Zhenyuan Yin; George J. Moridis; George J. Moridis; George J. Moridis; Zheng Rong Chong; Praveen Linga;Laboratory-created samples of methane hydrate (MH)-bearing media are a necessity because of the rarity and difficulty of obtaining naturally-occurring samples. The hypothesis that the inevitable heterogeneity in the phase saturations of the laboratory samples may lead to unreliable and non-repeatable results provided the impetus for this study, which aimed to determine the conditions under which maximum uniformity can be achieved. To that end, we designed four experiments involving different multi-stage cooling regimes (in terms of their duration and number of stages) to induce MH formation under excess-water conditions. In the absence of direct visualization capabilities, we analysed the experimental results by means of numerical simulation, which provided high-resolution predictions of the spatial distributions of the phase saturations in the cores and enabled the estimation of the parameters controlling the kinetic MH-formation behaviour through history-matching. Analysis of the numerical results indicated that, under the conditions of the experiments and with the design of the reactor, significant heterogeneities in phase saturation distributions were observed in all cases, leading to the conclusion that it is not possible to obtain cores with uniform phase saturation. Additionally, contrary to expectations, heterogeneities increased with the number of cooling stages and the duration of cooling, and this was attributed to imperfect insulation of the upper part of the reactor. A set of simulations involving perfect insulation of the reactor top confirmed the validity of this assumption: (a) predicting the formation of high-uniformity MH-bearing cores that became more homogeneous as the number of cooling stages and the length of the cooling period increased; and (b) providing important information for the improvement of the standard design of the experimental apparatus for the laboratory creation of MH-bearing cores using the excess water method.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2019.05.077&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 53 citations 53 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2019.05.077&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020 TurkeyPublisher:Elsevier BV Serhat Karyeyen; Serhat Karyeyen; Ashwani K. Gupta; Edward Jahoda; Joseph S. Feser;Abstract Colorless Distributed Combustion is a combustion technique to reduce pollutants emission, reduce noise, enhance flame stability, promote a uniform thermal field distribution in the flame, and mitigate combustion instability. To achieve these conditions, hot reactive gases must be entrained into the oxidizer to reduce the oxygen concentration, which slows down the reaction rate to broaden and homogenize the reaction front. This paper focuses on the development of a distributed combustion index that will predict transition to favorable distributed combustion conditions over a range of conditions. Distributed conditions were achieved by adding either N2 or CO2 dilution to the oxidizer stream to simulate hot gas entrainment. The index developed here is for either N2 or CO2 dilution and focuses on the effects of heat release intensity, equivalence ratio, and mixture preheat temperature. The results show heat release intensities in the range of 5.72–9.53 MW/m3-atm to have minimal effect on the oxygen concentration corresponding to transition to distributed combustion. In contrast, equivalence ratio and preheat temperature provided strong effects on this transition. Decrease in equivalence ratio from 0.9 to 0.6 required increased oxygen concentration for transition to distributed conditions by some 4% with N2 as the diluent and only 3% with CO2 as the diluent. Increase in mixture preheat temperature from 300 to 700 K decreased oxygen concentration transition requirements by some 3% with N2 and 2% for CO2. Emission levels obtained showed ultra-low NO and CO under favorable distributed combustion condition. The distributed combustion index development presented here is aimed to help guide in the design and development of novel next generation of advanced colorless distributed combustors with much reduced further experimentation.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2020.114967&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 22 citations 22 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2020.114967&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2012 SpainPublisher:Elsevier BV J.D. Marcos; E. Palacios; D.M. Admiraal; M. Izquierdo; M. Izquierdo;This paper investigates thermal mixing caused by the inflow from one or two round, horizontal, buoyant jets in a water storage tank, which is part of a thermal solar installation. A set of experiments was carried out in a rectangular tank with a capacity of 0.3 m3, with one or two constant temperature inflows. As a result, two correlations based on temperature measurements have been developed. One of the correlations predicts the size of a zone of homogenous temperature, referred to herein as the mixing zone, which develops when a single hot inflow impinges on the opposite wall of the tank. The other identifies the degree of mixing resulting from the interaction between a hot inflow and a cold inflow located below the hot one. The correlations are combined with energy balances to predict the amount of hot water available in a tank with open side inlets and the corresponding temperatures of the outflows. Outdoor measurements were also performed in a solar installation, in which a commercial water storage tank with a 1.5 m3 capacity, heated by a solar collector array with a useful surface area of 42.2 m2, drives a LiBr–H2O absorption chiller. Comparison of the predicted and measured outflow temperatures under a variety of weather conditions shows a maximum difference of 3 °C.
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2012 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2011.08.001&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2012 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2011.08.001&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022 SpainPublisher:Elsevier BV Funded by:EC | CUSTOM-ARTEC| CUSTOM-ARTAuthors: Resalati, Shahaboddin; Okoroafor, Tobechi; Maalouf, Amani; Saucedo Silva, Edgardo Ademar; +1 AuthorsResalati, Shahaboddin; Okoroafor, Tobechi; Maalouf, Amani; Saucedo Silva, Edgardo Ademar; Placidi, Marcel Jose;handle: 2117/370823
Thin-film photovoltaics (PV) cells offer several benefits over conventional first-generation PV technologies, including lighter weight, flexibility, and lower power generation cost. Among the competing thin-film technologies, chalcogenide solar cells offer promising performance on efficiency and technological maturity level. However, in order to appraise the performance of the technology thoroughly, issues such as raw materials scarcity, toxicity, and environmental impacts need to be investigated in detail. This paper therefore, for the first time, presents a cradle to gate life cycle assessment for four different emerging chalcogenide PV cells, and compares their results with copper zinc tin sulfide (CZTS) and the commercially available CIGS to examine their effectiveness in reducing the environmental impacts associated with PV technologies. To allow for a full range of indicators, life cycle assessment methods CML 2001, IMPACT 2002+, and ILCD 2011 were used to analyse the results. The results identify environmental hotspots associated with different materials and components and demonstrate that using current efficiencies, the environmental impact of copper indium gallium selenide (CIGS) for generating 1kWh electricity was lower than that of the other studied cells. However, at comparable efficiencies the antimony-based cells offered the lowest environmental impacts in all impact categories. The effect of materials used was also found to be lower than the impact of electricity consumed throughout the manufacturing process, with the absorber layer contributing the most to the majority of the impact categories examined. In terms of chemicals consumed, cadmium acetate contributed significantly to the majority of the environmental impacts. Stainless steel in the substrate/insulating layer and molybdenum in the back contact both contributed considerably to the toxicity and ozone depletion impact categories. This paper demonstrates considerable environmental benefits associated with non-toxic chalcogenide PV cells suggesting that the current environmental concerns can be addressed effectively using alternative materials and manufacturing techniques if current efficiencies are improved. Peer Reviewed
Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2022License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2022 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2022.118888&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 24 citations 24 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
visibility 40visibility views 40 download downloads 91 Powered bymore_vert Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2022License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2022 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2022.118888&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2021 China (People's Republic of), China (People's Republic of), China (People's Republic of), United StatesPublisher:Elsevier BV Han Li; Zhe Wang; Tianzhen Hong; Andrew Parker; Monica Neukomm;The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. The commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116721&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 36 citations 36 popularity Top 10% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.116721&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 United KingdomPublisher:Elsevier BV Funded by:UKRI | Heat supply through Solar..., EC | H-DisNetUKRI| Heat supply through Solar Thermochemical Residential Seasonal Storage (Heat-STRESS) ,EC| H-DisNetAuthors: Giampieri, Alessandro; Ma, Zhiwei; Smallbone, Andrew; Roskilly, Anthony Paul;Abstract In an effort to minimise electricity consumption and greenhouse gases emissions, the heating, ventilation and air-conditioning sector has focused its attention on developing alternative solutions to electrically-driven vapour-compression cooling. Liquid desiccant air-conditioning systems represent an energy-efficient and more environmentally friendly alternative technology for dehumidification and cooling, particularly in those cases with high latent loads to maintain indoor air quality and comfort conditions. This technology is considered particularly efficient in hot and humid climates. As a matter of fact, the choice of the desiccant solution influences the overall performance of the system. The current paper reviews the working principle of liquid desiccant systems, focusing on the thermodynamic properties of the desiccant solutions and describes an evaluation of the reference thermodynamic properties of different desiccant solutions to identify which thermodynamic, physical, transport property influences the liquid desiccant process and to what extent. The comparison of these thermodynamic properties for the commonly used desiccants is conducted to estimate which fluid could perform most favourably in the system. The economic factors and the effect of different applications and climatic conditions on the system performance are also described. The paper is intended to be the first step in the evaluation of alternative desiccant fluids able to overcome the problems related to the use of the common desiccant solutions, such as crystallization and corrosion to metals. Ionic liquids seem a promising alternative working fluid in liquid desiccant air-conditioning systems and their characteristics and cost are discussed.
Durham University: D... arrow_drop_down Durham University: Durham Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://dro.dur.ac.uk/29398/Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.03.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 92 citations 92 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Durham University: D... arrow_drop_down Durham University: Durham Research OnlineArticle . 2018License: CC BY NC NDFull-Text: http://dro.dur.ac.uk/29398/Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.03.112&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2016 CroatiaPublisher:Elsevier BV David Vuilleumier; Ivan Taritas; Benjamin Wolk; Darko Kozarac; Samveg Saxena; Robert W. Dibble;Abstract Advanced combustion engine (ACE) research is typically carried out on single-cylinder research engines. These engines are designed to tightly control fueling and conditions at intake valve closure (IVC) and to precisely measure in-cylinder conditions and emissions. However, to be able to measure and control engine operation so precisely, these research engines typically do not feature intake and exhaust tracts that resemble those in production engines, specifically in regards to turbomachinery, heat exchangers, and exhaust gas recirculation (EGR) systems. For this reason, these research engines are effective for understanding in-cylinder combustion parameters such as heat release rate, burn duration, combustion efficiency, pollutant formation, and exhaust valve opening (EVO) conditions. This paper applies high fidelity simulations to determine the feasibility of achieving a chosen single cylinder engine operating point on a production type homogeneous charge compression ignition (HCCI) engine, using a partial fuel stratification (PFS) strategy. To accomplish this, a Converge 3 dimensional (3D) – computational fluid dynamics (CFD) model of the experimental combustion chamber and intake and exhaust runners was created to simulate the experimental engine. This model was used to simulate an operating point achieved experimentally, as well as to determine the sensitivity of the operating point to variations in intake pressure, intake temperature, injection timing, injected mass, and EGR fraction. The results from these simulations were fed into a 1-dimensional engine simulation created in AVL Boost, featuring production-type intake and exhaust systems, including turbomachinery and heat exchangers necessary to create the required IVC conditions. This full engine simulation was used to assess the cycle efficiency of the engine at the experimental operating condition, and to assess whether changes to this operating point in intake temperature, intake pressure, direct injection timing, or fueling are beneficial to the cycle efficiency and engine-out emissions. In addition, the sensitivity of promising engine operating points to injection timing and injection mass are determined to evaluate the potential stability of these operating points.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.05.043&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 8 citations 8 popularity Average influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2016.05.043&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 BelgiumPublisher:Elsevier BV Funded by:EC | VADEMECOM, EC | CLEAN-GasEC| VADEMECOM ,EC| CLEAN-GasAlberto Cuoci; Zhiyi Li; Marco Ferrarotti; Marco Ferrarotti; Alessandro Parente;Abstract The present work focuses on the numerical simulation of Moderate or Intense Low oxygen Dilution combustion condition, using the Partially-Stirred Reactor model for turbulence-chemistry interactions. The Partially-Stirred Reactor model assumes that reactions are confined in a specific region of the computational cell, whose mass fraction depends both on the mixing and the chemical time scales. Therefore, the appropriate choice of mixing and chemical time scales becomes crucial to ensure the accuracy of the numerical simulation prediction. Results show that the most appropriate choice for mixing time scale in Moderate or Intense Low oxygen Dilution combustion regime is to use a dynamic evaluation, in which the ratio between the variance of mixture fraction and its dissipation rate is adopted, rather than global estimations based on Kolmogorov or integral mixing scales. This is supported by the validation of the numerical results against experimental profiles of temperature and species mass fractions, available from measurements on the Adelaide Jet in Hot Co-flow burner. Different approaches for chemical time scale evaluation are also compared, using the species formation rates, the reaction rates and the eigenvalues of the formation rate Jacobian matrix. Different co-flow oxygen dilution levels and Reynolds numbers are considered in the validation work, to evaluate the applicability of Partially-Stirred Reactor approach over a wide range of operating conditions. Moreover, the influence of specifying uniform and non-uniform boundary conditions for the chemical scalars is assessed. The present work sheds light on the key mechanisms of turbulence-chemistry interactions in advanced combustion regimes. At the same time, it provides essential information to advance the predictive nature of computational tools used by scientists and engineers, to support the development of new technologies.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.04.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 54 citations 54 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.04.085&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Elsevier BV Funded by:EC | sEEnergiesEC| sEEnergiesAuthors: Meunier, Simon; Protopapadaki, Christina; Baetens, Ruben; Saelens, Dirk;Abstract Integrating low-carbon technologies (e.g. heat pumps, photovoltaic systems) in buildings influences the stability of the low-voltage grid, which therefore often requires to be reinforced. This article proposes a techno-economic methodology to identify the reinforcements needed to maintain grid stability at the lowest life-cycle cost. Novel contributions include the consideration of three-phase connection of low-carbon technologies as a reinforcement option and the fact that we study to what extent grid reinforcements can mitigate voltage unbalance issues. Additionally, to reduce computing time, a dummy island approach is used, whereby one feeder is modelled in detail and the remainder of the distribution island is represented by an aggregated load. Finally, random repetitions are proposed, to consider uncertainties related to building properties, occupants and the location of low-carbon technologies in the feeders. The methodology is applied to investigate the integration of heat pumps and photovoltaic systems in typical Belgian rural and urban grids. For the rural grid, heat pumps may lead to significant reinforcement costs (up to 1230 €/dwelling), mainly due to voltage stability problems. For the urban grid, heat pump and photovoltaic integration causes low reinforcement cost (
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.117057&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 15 citations 15 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2021.117057&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Publicly fundedFunded by:EC | ATBESTEC| ATBESTAuthors: Jerry D. Murphy; M.A. Voelklein; Davis Rusmanis;Abstract This study investigated in-situ and ex-situ biological methanation strategies for biogas upgrading potential. The addition and circulation of hydrogen with a ceramic gas diffuser unit revealed positive effects on the methanogenic process. A short-term maximum methane productivity of 2.5 L CH4 per L reactor volume per day (LVR−1 d−1) was obtained in-situ. Adverse effects of elevated dissolved hydrogen concentrations on acetogenesis became evident. Ex-situ methanation in a reactor subjected to gas recirculation for recurrent 24 h periods achieved methane formation rates of 3.7 L CH4 LVR−1 d−1. A biomethane with methane concentrations in excess of 96% successfully demonstrated the potential for gas grid injection. A theoretic model supplying gases continuously into a sequential ex-situ reactor system and steadily displacing the upgraded biogas confirmed similar methane formation performance and was advanced to a full-scale concept. Gas conversion efficiency of 95% producing biomethane at 85% methane content was attained. A hybrid model, where an in-situ grass digester is followed by an ex-situ reactor, is proposed as a novel upgrading strategy.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.11.006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 131 citations 131 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2018.11.006&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 United StatesPublisher:Elsevier BV Zhenyuan Yin; Zhenyuan Yin; George J. Moridis; George J. Moridis; George J. Moridis; Zheng Rong Chong; Praveen Linga;Laboratory-created samples of methane hydrate (MH)-bearing media are a necessity because of the rarity and difficulty of obtaining naturally-occurring samples. The hypothesis that the inevitable heterogeneity in the phase saturations of the laboratory samples may lead to unreliable and non-repeatable results provided the impetus for this study, which aimed to determine the conditions under which maximum uniformity can be achieved. To that end, we designed four experiments involving different multi-stage cooling regimes (in terms of their duration and number of stages) to induce MH formation under excess-water conditions. In the absence of direct visualization capabilities, we analysed the experimental results by means of numerical simulation, which provided high-resolution predictions of the spatial distributions of the phase saturations in the cores and enabled the estimation of the parameters controlling the kinetic MH-formation behaviour through history-matching. Analysis of the numerical results indicated that, under the conditions of the experiments and with the design of the reactor, significant heterogeneities in phase saturation distributions were observed in all cases, leading to the conclusion that it is not possible to obtain cores with uniform phase saturation. Additionally, contrary to expectations, heterogeneities increased with the number of cooling stages and the duration of cooling, and this was attributed to imperfect insulation of the upper part of the reactor. A set of simulations involving perfect insulation of the reactor top confirmed the validity of this assumption: (a) predicting the formation of high-uniformity MH-bearing cores that became more homogeneous as the number of cooling stages and the length of the cooling period increased; and (b) providing important information for the improvement of the standard design of the experimental apparatus for the laboratory creation of MH-bearing cores using the excess water method.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2019.05.077&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 53 citations 53 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2019.05.077&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020 TurkeyPublisher:Elsevier BV Serhat Karyeyen; Serhat Karyeyen; Ashwani K. Gupta; Edward Jahoda; Joseph S. Feser;Abstract Colorless Distributed Combustion is a combustion technique to reduce pollutants emission, reduce noise, enhance flame stability, promote a uniform thermal field distribution in the flame, and mitigate combustion instability. To achieve these conditions, hot reactive gases must be entrained into the oxidizer to reduce the oxygen concentration, which slows down the reaction rate to broaden and homogenize the reaction front. This paper focuses on the development of a distributed combustion index that will predict transition to favorable distributed combustion conditions over a range of conditions. Distributed conditions were achieved by adding either N2 or CO2 dilution to the oxidizer stream to simulate hot gas entrainment. The index developed here is for either N2 or CO2 dilution and focuses on the effects of heat release intensity, equivalence ratio, and mixture preheat temperature. The results show heat release intensities in the range of 5.72–9.53 MW/m3-atm to have minimal effect on the oxygen concentration corresponding to transition to distributed combustion. In contrast, equivalence ratio and preheat temperature provided strong effects on this transition. Decrease in equivalence ratio from 0.9 to 0.6 required increased oxygen concentration for transition to distributed conditions by some 4% with N2 as the diluent and only 3% with CO2 as the diluent. Increase in mixture preheat temperature from 300 to 700 K decreased oxygen concentration transition requirements by some 3% with N2 and 2% for CO2. Emission levels obtained showed ultra-low NO and CO under favorable distributed combustion condition. The distributed combustion index development presented here is aimed to help guide in the design and development of novel next generation of advanced colorless distributed combustors with much reduced further experimentation.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2020.114967&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 22 citations 22 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2020.114967&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2012 SpainPublisher:Elsevier BV J.D. Marcos; E. Palacios; D.M. Admiraal; M. Izquierdo; M. Izquierdo;This paper investigates thermal mixing caused by the inflow from one or two round, horizontal, buoyant jets in a water storage tank, which is part of a thermal solar installation. A set of experiments was carried out in a rectangular tank with a capacity of 0.3 m3, with one or two constant temperature inflows. As a result, two correlations based on temperature measurements have been developed. One of the correlations predicts the size of a zone of homogenous temperature, referred to herein as the mixing zone, which develops when a single hot inflow impinges on the opposite wall of the tank. The other identifies the degree of mixing resulting from the interaction between a hot inflow and a cold inflow located below the hot one. The correlations are combined with energy balances to predict the amount of hot water available in a tank with open side inlets and the corresponding temperatures of the outflows. Outdoor measurements were also performed in a solar installation, in which a commercial water storage tank with a 1.5 m3 capacity, heated by a solar collector array with a useful surface area of 42.2 m2, drives a LiBr–H2O absorption chiller. Comparison of the predicted and measured outflow temperatures under a variety of weather conditions shows a maximum difference of 3 °C.
Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2012 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2011.08.001&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Recolector de Cienci... arrow_drop_down Recolector de Ciencia Abierta, RECOLECTAArticle . 2012 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2011.08.001&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022 SpainPublisher:Elsevier BV Funded by:EC | CUSTOM-ARTEC| CUSTOM-ARTAuthors: Resalati, Shahaboddin; Okoroafor, Tobechi; Maalouf, Amani; Saucedo Silva, Edgardo Ademar; +1 AuthorsResalati, Shahaboddin; Okoroafor, Tobechi; Maalouf, Amani; Saucedo Silva, Edgardo Ademar; Placidi, Marcel Jose;handle: 2117/370823
Thin-film photovoltaics (PV) cells offer several benefits over conventional first-generation PV technologies, including lighter weight, flexibility, and lower power generation cost. Among the competing thin-film technologies, chalcogenide solar cells offer promising performance on efficiency and technological maturity level. However, in order to appraise the performance of the technology thoroughly, issues such as raw materials scarcity, toxicity, and environmental impacts need to be investigated in detail. This paper therefore, for the first time, presents a cradle to gate life cycle assessment for four different emerging chalcogenide PV cells, and compares their results with copper zinc tin sulfide (CZTS) and the commercially available CIGS to examine their effectiveness in reducing the environmental impacts associated with PV technologies. To allow for a full range of indicators, life cycle assessment methods CML 2001, IMPACT 2002+, and ILCD 2011 were used to analyse the results. The results identify environmental hotspots associated with different materials and components and demonstrate that using current efficiencies, the environmental impact of copper indium gallium selenide (CIGS) for generating 1kWh electricity was lower than that of the other studied cells. However, at comparable efficiencies the antimony-based cells offered the lowest environmental impacts in all impact categories. The effect of materials used was also found to be lower than the impact of electricity consumed throughout the manufacturing process, with the absorber layer contributing the most to the majority of the impact categories examined. In terms of chemicals consumed, cadmium acetate contributed significantly to the majority of the environmental impacts. Stainless steel in the substrate/insulating layer and molybdenum in the back contact both contributed considerably to the toxicity and ozone depletion impact categories. This paper demonstrates considerable environmental benefits associated with non-toxic chalcogenide PV cells suggesting that the current environmental concerns can be addressed effectively using alternative materials and manufacturing techniques if current efficiencies are improved. Peer Reviewed
Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2022License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2022 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2022.118888&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 24 citations 24 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
visibility 40visibility views 40 download downloads 91 Powered bymore_vert Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2022License: CC BY NC NDData sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2022 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.apenergy.2022.118888&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu