- home
- Advanced Search
- Energy Research
- Open Access
- Closed Access
- IT
- FR
- Energy
- Energy Research
- Open Access
- Closed Access
- IT
- FR
- Energy
description Publicationkeyboard_double_arrow_right Article , Journal 2013 Netherlands, Netherlands, Netherlands, Netherlands, ItalyPublisher:Elsevier BV Lopes Ferreira, HM (Helder); Garde, R; Fulli, G (Gianluca); Kling, WL (Wil); Peças Lopes, JA (João);handle: 11583/2570345
In the current situation with the unprecedented deployment of clean technologies for electricity generation, it is natural to expect that storage will play an important role in electricity networks. This paper provides a qualitative methodology to select the appropriate technology or mix of technologies for different applications. The multiple comparisons according to different characteristics distinguish this paper from others about energy storage systems. Firstly, the different technologies available for energy storage, as discussed in the literature, are described and compared. The characteristics of the technologies are explained, including their current availability. In order to gain a better perspective, availability is cross-compared with maturity level. Moreover, information such as ratings, energy density, durability and costs is provided in table and graphic format for a straightforward comparison. Additionally, the different electric grid applications of energy storage technologies are described and categorised. For each of the categories, we describe the available technologies, both mature and potential. Finally, methods for connecting storage technologies are discussed.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 383 citations 383 popularity Top 0.1% influence Top 1% impulse Top 0.1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013 Netherlands, Netherlands, Netherlands, Netherlands, ItalyPublisher:Elsevier BV Lopes Ferreira, HM (Helder); Garde, R; Fulli, G (Gianluca); Kling, WL (Wil); Peças Lopes, JA (João);handle: 11583/2570345
In the current situation with the unprecedented deployment of clean technologies for electricity generation, it is natural to expect that storage will play an important role in electricity networks. This paper provides a qualitative methodology to select the appropriate technology or mix of technologies for different applications. The multiple comparisons according to different characteristics distinguish this paper from others about energy storage systems. Firstly, the different technologies available for energy storage, as discussed in the literature, are described and compared. The characteristics of the technologies are explained, including their current availability. In order to gain a better perspective, availability is cross-compared with maturity level. Moreover, information such as ratings, energy density, durability and costs is provided in table and graphic format for a straightforward comparison. Additionally, the different electric grid applications of energy storage technologies are described and categorised. For each of the categories, we describe the available technologies, both mature and potential. Finally, methods for connecting storage technologies are discussed.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 383 citations 383 popularity Top 0.1% influence Top 1% impulse Top 0.1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Canada, France, CanadaPublisher:Elsevier BV Boukenoui, Rachid; Ghanes, Malek; Barbot, Jean-Pierre; Bradai, Rafik; Mellit, Adel; Salhi, Hassen;This paper presents different Maximum Power Point Tracking (MPPT) methods belonging to different classes as well as two overviews. The first was about the procedures used in the test and evaluation of MPPTs. The second is an overview of Fuzzy Logic Controller (FLC) MPPTs and improved MPPTs. Conventional MPPTs such as Perturb and Observe (P&O), Hill Climbing (HC) and Incremental Conductance (InCond); Improved MPPTs (are the modified versions of conventional MPPTs) such as Improved Incremental Conductance (Improved-InCond) and intelligent MPPTs such as FLC have been implemented and tested under two different levels of irradiance and temperature. A detailed description about the hardware and software implementation platforms (designed and built in our laboratory) is provided. Based on measured data, the MPPTs under consideration have been evaluated and compared in terms of different criteria, showing the advantages and disadvantages of each one. The comparison results showed that Improved-InCond gives a fast convergence to the MPP(Maximum Power Point). Whereas, FLC is able to adapt to the variation of irradiance and temperature levels. Thereby, a good performance is obtained wherein the MPP is reached in a short time as well as the power ripples are very small.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu45 citations 45 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Canada, France, CanadaPublisher:Elsevier BV Boukenoui, Rachid; Ghanes, Malek; Barbot, Jean-Pierre; Bradai, Rafik; Mellit, Adel; Salhi, Hassen;This paper presents different Maximum Power Point Tracking (MPPT) methods belonging to different classes as well as two overviews. The first was about the procedures used in the test and evaluation of MPPTs. The second is an overview of Fuzzy Logic Controller (FLC) MPPTs and improved MPPTs. Conventional MPPTs such as Perturb and Observe (P&O), Hill Climbing (HC) and Incremental Conductance (InCond); Improved MPPTs (are the modified versions of conventional MPPTs) such as Improved Incremental Conductance (Improved-InCond) and intelligent MPPTs such as FLC have been implemented and tested under two different levels of irradiance and temperature. A detailed description about the hardware and software implementation platforms (designed and built in our laboratory) is provided. Based on measured data, the MPPTs under consideration have been evaluated and compared in terms of different criteria, showing the advantages and disadvantages of each one. The comparison results showed that Improved-InCond gives a fast convergence to the MPP(Maximum Power Point). Whereas, FLC is able to adapt to the variation of irradiance and temperature levels. Thereby, a good performance is obtained wherein the MPP is reached in a short time as well as the power ripples are very small.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu45 citations 45 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal , Other literature type 2019 FrancePublisher:Elsevier BV Funded by:ANR | FEMANR| FEMAuthors: Thiébaut, Maxime; Sentchev, Alexei; Bailly Du Bois, Pascal;Abstract Tidal circulation and tidal stream resource in Alderney Race (Raz Blanchard) were assessed by using a towed acoustic Doppler current profiler (ADCP) system and tidal modeling. Optimal Interpolation (OI) was applied to process the underway velocity measurements recorded at neap tide flood and ebb flow. The interpolation technique allows reconstructing space-time evolution of the velocity field within the domain during surveying periods. The method employs velocity covariances derived from numerical simulations by a 2D hydrodynamic model MARS. Model covariances are utilized by the OI algorithm to obtain the most likely evolution of the velocity field under the constraints provided by the ADCP observations and their error statistics. The resulting velocity fields were used for assessing the tidal stream resource at site. The largest overall difference between the kinetic power density derived from simulated and interpolated velocity fields was found for ebb tide. Model simulations constrained by velocity measurements demonstrated a significant (up to 30%) decrease of power available in the flow. A significant change in spatial pattern of power density distribution was also identified. It is demonstrated that by merging high resolution velocity measurements at tidal energy site with modeling the tidal stream potential estimation becomes more accurate.
Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 22 citations 22 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal , Other literature type 2019 FrancePublisher:Elsevier BV Funded by:ANR | FEMANR| FEMAuthors: Thiébaut, Maxime; Sentchev, Alexei; Bailly Du Bois, Pascal;Abstract Tidal circulation and tidal stream resource in Alderney Race (Raz Blanchard) were assessed by using a towed acoustic Doppler current profiler (ADCP) system and tidal modeling. Optimal Interpolation (OI) was applied to process the underway velocity measurements recorded at neap tide flood and ebb flow. The interpolation technique allows reconstructing space-time evolution of the velocity field within the domain during surveying periods. The method employs velocity covariances derived from numerical simulations by a 2D hydrodynamic model MARS. Model covariances are utilized by the OI algorithm to obtain the most likely evolution of the velocity field under the constraints provided by the ADCP observations and their error statistics. The resulting velocity fields were used for assessing the tidal stream resource at site. The largest overall difference between the kinetic power density derived from simulated and interpolated velocity fields was found for ebb tide. Model simulations constrained by velocity measurements demonstrated a significant (up to 30%) decrease of power available in the flow. A significant change in spatial pattern of power density distribution was also identified. It is demonstrated that by merging high resolution velocity measurements at tidal energy site with modeling the tidal stream potential estimation becomes more accurate.
Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 22 citations 22 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, ItalyPublisher:Elsevier BV Funded by:EC | INNOSTORAGE, EC | INPATH-TESEC| INNOSTORAGE ,EC| INPATH-TESDomenico Mazzeo; Giuseppe Oliveti; Alvaro de Gracia; Julià Coma; Aran Solé; Luisa F. Cabeza;handle: 10459.1/60248 , 20.500.11770/270333 , 2117/112028
Phase change materials (PCM) are used in many industrial and residential applications for their advantageous characteristic of high capacity of latent thermal storage by means of an isothermal process. In this context, it is very useful to have predictive mathematical models for the analysis of the thermal performance and for the thermal design of these layers. In this work, an experimental validation of an analytical model that resolves the steady periodic heat transfer problem in a finite layer of PCM is presented. The experimental investigation was conducted employing a PCM with thermophysical and thermochemical behavior very close to those hypothesized in the formulation of the analytical model. For the evaluation of the thermophysical properties of the PCM sample used, an experimental procedure created by the authors was employed. In all tests realized in a sinusoidal and non-sinusoidal periodic regime, the comparison between the measured and calculated trends of the temperature at different sample heights and of the surface heat fluxes show an excellent agreement. Moreover, also having verified the analytical total stored energy, the analytical model constitutes a valid instrument for the evaluation of the latent and sensible contribution and the trend in time of the position of the bi-phase interface. Peer Reviewed
Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 37 citations 37 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
visibility 42visibility views 42 download downloads 131 Powered bymore_vert Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, ItalyPublisher:Elsevier BV Funded by:EC | INNOSTORAGE, EC | INPATH-TESEC| INNOSTORAGE ,EC| INPATH-TESDomenico Mazzeo; Giuseppe Oliveti; Alvaro de Gracia; Julià Coma; Aran Solé; Luisa F. Cabeza;handle: 10459.1/60248 , 20.500.11770/270333 , 2117/112028
Phase change materials (PCM) are used in many industrial and residential applications for their advantageous characteristic of high capacity of latent thermal storage by means of an isothermal process. In this context, it is very useful to have predictive mathematical models for the analysis of the thermal performance and for the thermal design of these layers. In this work, an experimental validation of an analytical model that resolves the steady periodic heat transfer problem in a finite layer of PCM is presented. The experimental investigation was conducted employing a PCM with thermophysical and thermochemical behavior very close to those hypothesized in the formulation of the analytical model. For the evaluation of the thermophysical properties of the PCM sample used, an experimental procedure created by the authors was employed. In all tests realized in a sinusoidal and non-sinusoidal periodic regime, the comparison between the measured and calculated trends of the temperature at different sample heights and of the surface heat fluxes show an excellent agreement. Moreover, also having verified the analytical total stored energy, the analytical model constitutes a valid instrument for the evaluation of the latent and sensible contribution and the trend in time of the position of the bi-phase interface. Peer Reviewed
Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 37 citations 37 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
visibility 42visibility views 42 download downloads 131 Powered bymore_vert Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 ItalyPublisher:Elsevier BV Paweł Ocłon; Monika Rerak; Ravipudi Venkata Rao; Piotr Cisek; Andrea Vallati; Dariusz Jakubek; Bartosz Rozegnał;handle: 11573/1451232
Abstract This paper presents a modified Jaya algorithm (MJaya) for optimizing the material costs and electric-thermal performance of an Underground Power Cable System (UPCS). Three power cables arranged in flat formation are considered. Three XLPE high voltage cables are situated in the thermal backfill layer for ensuring the optimal thermal performance of the cable system. The cable backfill dimensions, cable backfill material, and cable conductor area are selected as design variables in the optimization problem. In the study, the Finite Element Method model is validated experimentally. The Particle Swarm Optimization (PSO), Jaya, and MJaya algorithms are used for multiobjective optimization in order to design a cable system in such a way to minimize the cable backfill costs and maximize the allowable electric current flowing through the cables. For the case study, calculations performed using the Jaya algorithm indicated 1.7 mln Euro cable system costs while cable ampacity is equal to I = 1460 A. The calculations are performed for the objective function values equal to w1 = 0.5 and w2 = 0.5. Such an optimization parameters set allow obtaining low costs of UPCS alongside with reasonable cable line ampacity. What is more, the results of the optimization obtained by Jaya, MJaya, and PSO algorithms are compared. Therefore, Coverage and Hypervolume metrics are incorporated. It is concluded that both the Jaya and MJaya algorithms performed better when compared to the PSO algorithm.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 30 citations 30 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 ItalyPublisher:Elsevier BV Paweł Ocłon; Monika Rerak; Ravipudi Venkata Rao; Piotr Cisek; Andrea Vallati; Dariusz Jakubek; Bartosz Rozegnał;handle: 11573/1451232
Abstract This paper presents a modified Jaya algorithm (MJaya) for optimizing the material costs and electric-thermal performance of an Underground Power Cable System (UPCS). Three power cables arranged in flat formation are considered. Three XLPE high voltage cables are situated in the thermal backfill layer for ensuring the optimal thermal performance of the cable system. The cable backfill dimensions, cable backfill material, and cable conductor area are selected as design variables in the optimization problem. In the study, the Finite Element Method model is validated experimentally. The Particle Swarm Optimization (PSO), Jaya, and MJaya algorithms are used for multiobjective optimization in order to design a cable system in such a way to minimize the cable backfill costs and maximize the allowable electric current flowing through the cables. For the case study, calculations performed using the Jaya algorithm indicated 1.7 mln Euro cable system costs while cable ampacity is equal to I = 1460 A. The calculations are performed for the objective function values equal to w1 = 0.5 and w2 = 0.5. Such an optimization parameters set allow obtaining low costs of UPCS alongside with reasonable cable line ampacity. What is more, the results of the optimization obtained by Jaya, MJaya, and PSO algorithms are compared. Therefore, Coverage and Hypervolume metrics are incorporated. It is concluded that both the Jaya and MJaya algorithms performed better when compared to the PSO algorithm.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 30 citations 30 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004Publisher:Elsevier BV A. Jamali; M. Kouhila; Ali Idlimam; Mostafa Mahrouz; Siham Lahsasni;Abstract This paper presents the thin layer convective solar drying and mathematical modeling of prickly pear peel. For these purposes, an indirect forced convection solar dryer consisting of a solar air collector, an auxiliary heater, a circulation fan and a drying cabinet is used for drying experiments. Moreover, the prickly pear peel is sufficiently dried in the ranges of 32 to 36 °C of ambient air temperature, 50 to 60 °C of drying air temperature, 23 to 34% of relative humidity, 0.0277 to 0.0833 m3/s of drying air flow rate and 200 to 950 W/m2 of daily solar radiation. The experimental drying curves show only a falling drying rate period. The main factor in controlling the drying rate was found to be the drying air temperature. The drying rate equation is determined empirically from the characteristic drying curve. Also, the experimental drying curves obtained were fitted to a number of mathematical models. The Midilli–Kucuk drying model was found to satisfactorily describe the solar drying curves of prickly pear peel with a correlation coefficient (r) of 0.9998 and chi-square (χ2) of 4.6572 10−5.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu111 citations 111 popularity Top 1% influence Top 1% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004Publisher:Elsevier BV A. Jamali; M. Kouhila; Ali Idlimam; Mostafa Mahrouz; Siham Lahsasni;Abstract This paper presents the thin layer convective solar drying and mathematical modeling of prickly pear peel. For these purposes, an indirect forced convection solar dryer consisting of a solar air collector, an auxiliary heater, a circulation fan and a drying cabinet is used for drying experiments. Moreover, the prickly pear peel is sufficiently dried in the ranges of 32 to 36 °C of ambient air temperature, 50 to 60 °C of drying air temperature, 23 to 34% of relative humidity, 0.0277 to 0.0833 m3/s of drying air flow rate and 200 to 950 W/m2 of daily solar radiation. The experimental drying curves show only a falling drying rate period. The main factor in controlling the drying rate was found to be the drying air temperature. The drying rate equation is determined empirically from the characteristic drying curve. Also, the experimental drying curves obtained were fitted to a number of mathematical models. The Midilli–Kucuk drying model was found to satisfactorily describe the solar drying curves of prickly pear peel with a correlation coefficient (r) of 0.9998 and chi-square (χ2) of 4.6572 10−5.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu111 citations 111 popularity Top 1% influence Top 1% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 France, France, France, France, ItalyPublisher:Elsevier BV Funded by:EC | ERANETMEDEC| ERANETMEDHout, Mohamad; Ghaddar, Nesreen; Ghali, Kamel; Ismail, Nagham; Simonetti, Marco; Fracastoro, Giovanni Vincenzo; Virgone, Joseph; Zoughaib, Assaad;handle: 11583/2704030
A novel transport model is developed for a space conditioned by a cooled liquid desiccant dehumidification membrane ceiling (LDMC-C) and displacement ventilation DV in which the space is divided into three zones: an occupied cool with fresh air zone; an upper recirculation zone; and a ceiling adjacent boundary layer zone where the air is drawn at the exhaust grill. The adjacent air boundary layer at the ceiling membrane predicted the latent and sensible heat transfer to the desiccant solution. The boundary model was validated experimentally in a climatic chamber. The developed model predicted of the LDMC-C/DV system operational parameters such as the supply flow rate and temperature and the liquid desiccant concentration, flow rate, and inlet temperature that meet thermal comfort and air quality requirements. Extensive simulations were performed on a typical office load of 75 W/m2 to generate design charts of the system for three DV supply air temperatures of 18, 20, and 22 °C to identify the appropriate DV flow rate and inlet desiccant (CaCl2) solution temperature that provide comfort and air quality and ensures that condensation is unlikely to occur. The LDMC sensible and latent load removal from the space load is directly read off the charts.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 France, France, France, France, ItalyPublisher:Elsevier BV Funded by:EC | ERANETMEDEC| ERANETMEDHout, Mohamad; Ghaddar, Nesreen; Ghali, Kamel; Ismail, Nagham; Simonetti, Marco; Fracastoro, Giovanni Vincenzo; Virgone, Joseph; Zoughaib, Assaad;handle: 11583/2704030
A novel transport model is developed for a space conditioned by a cooled liquid desiccant dehumidification membrane ceiling (LDMC-C) and displacement ventilation DV in which the space is divided into three zones: an occupied cool with fresh air zone; an upper recirculation zone; and a ceiling adjacent boundary layer zone where the air is drawn at the exhaust grill. The adjacent air boundary layer at the ceiling membrane predicted the latent and sensible heat transfer to the desiccant solution. The boundary model was validated experimentally in a climatic chamber. The developed model predicted of the LDMC-C/DV system operational parameters such as the supply flow rate and temperature and the liquid desiccant concentration, flow rate, and inlet temperature that meet thermal comfort and air quality requirements. Extensive simulations were performed on a typical office load of 75 W/m2 to generate design charts of the system for three DV supply air temperatures of 18, 20, and 22 °C to identify the appropriate DV flow rate and inlet desiccant (CaCl2) solution temperature that provide comfort and air quality and ensures that condensation is unlikely to occur. The LDMC sensible and latent load removal from the space load is directly read off the charts.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1999 ItalyPublisher:Elsevier BV Authors: SCHIBUOLA, LUIGI;handle: 11578/732
Abstract A total heat recovery system performances are analysed by monitoring building–plant system long term behaviour. Some of the installed chillers offer in fact the possibility of a total recovery of the heat rejected by condenser. The results are very satisfactory both in energy and economic–financial terms. The experimental test takes advantage of the supervisor just existing in the building. Therefore it is an example of how these control systems can be used not only for safety and management needs, but also for a detailed performance analysis able to permit an easy simulation of the effects of different design and control options.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu6 citations 6 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1999 ItalyPublisher:Elsevier BV Authors: SCHIBUOLA, LUIGI;handle: 11578/732
Abstract A total heat recovery system performances are analysed by monitoring building–plant system long term behaviour. Some of the installed chillers offer in fact the possibility of a total recovery of the heat rejected by condenser. The results are very satisfactory both in energy and economic–financial terms. The experimental test takes advantage of the supervisor just existing in the building. Therefore it is an example of how these control systems can be used not only for safety and management needs, but also for a detailed performance analysis able to permit an easy simulation of the effects of different design and control options.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu6 citations 6 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006 ItalyPublisher:Elsevier BV BIANCHI, MICHELE; Cherubini F.; DE PASCALE, ANDREA; PERETTO, ANTONIO; Elmegaard B.;handle: 11585/36216
The availability of wet biomass as waste from a lot of industrial processes, from agriculture and farms and the need to meet the environmental standards force to investigate all options in order to dispose this waste. The possible treatments usually strongly depend on biomass characteristics, namely water content, density, organic content, heating value, etc. In particular, some of these wastes can be burnt in special plants, using them as energy supply for different processes. The study carried out with this paper is concerned with the promising utilization of the organic wastes from an existing poultry industry as fuel. Different plant configurations have been considered in order to make use of the oil and of the meat and bone meal, which are the by-products of the chicken cooking process. In particular, the process plant can be integrated with an energy supply plant, which can consist of an indirectly fired gas turbine. Moreover, a steam turbine plant or a simplified system for the supply of the only technological steam are investigated and compared. Thermodynamic and economic analysis have been carried out for the examined configurations in order to outline the basic differences in terms of energy savings/production and of return of the investments.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu21 citations 21 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006 ItalyPublisher:Elsevier BV BIANCHI, MICHELE; Cherubini F.; DE PASCALE, ANDREA; PERETTO, ANTONIO; Elmegaard B.;handle: 11585/36216
The availability of wet biomass as waste from a lot of industrial processes, from agriculture and farms and the need to meet the environmental standards force to investigate all options in order to dispose this waste. The possible treatments usually strongly depend on biomass characteristics, namely water content, density, organic content, heating value, etc. In particular, some of these wastes can be burnt in special plants, using them as energy supply for different processes. The study carried out with this paper is concerned with the promising utilization of the organic wastes from an existing poultry industry as fuel. Different plant configurations have been considered in order to make use of the oil and of the meat and bone meal, which are the by-products of the chicken cooking process. In particular, the process plant can be integrated with an energy supply plant, which can consist of an indirectly fired gas turbine. Moreover, a steam turbine plant or a simplified system for the supply of the only technological steam are investigated and compared. Thermodynamic and economic analysis have been carried out for the examined configurations in order to outline the basic differences in terms of energy savings/production and of return of the investments.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu21 citations 21 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 MalaysiaPublisher:Elsevier BV Authors: Sakiru Adebola Solarin; Muhammad Shahbaz; Shawkat Hammoudeh;Abstract This paper examines the relationship between hydroelectricity consumption and economic growth in China, while controlling for fossil fuel consumption, financial development, capital, institutional quality and globalization and its components for the period, 1970–2014. We have employed the Bayer and Hanck, (2013) combined cointegration test to examine the long-run relationships between those variables as well as the autoregressive distributed lag method with structural breaks as a robustness check. The empirical findings demonstrate a long-run relationship between those variables. Hydroelectricity consumption, fossil fuel consumption, capital, financial development and globalization and its components have a positive influence on GDP in China. The findings also provide predominant evidence on the long-run feedback hypothesis between the variables. The findings suggest that policies should be implemented to increase the role hydropower in the energy mix for sustainable economic growth in the country.
Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu28 citations 28 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 MalaysiaPublisher:Elsevier BV Authors: Sakiru Adebola Solarin; Muhammad Shahbaz; Shawkat Hammoudeh;Abstract This paper examines the relationship between hydroelectricity consumption and economic growth in China, while controlling for fossil fuel consumption, financial development, capital, institutional quality and globalization and its components for the period, 1970–2014. We have employed the Bayer and Hanck, (2013) combined cointegration test to examine the long-run relationships between those variables as well as the autoregressive distributed lag method with structural breaks as a robustness check. The empirical findings demonstrate a long-run relationship between those variables. Hydroelectricity consumption, fossil fuel consumption, capital, financial development and globalization and its components have a positive influence on GDP in China. The findings also provide predominant evidence on the long-run feedback hypothesis between the variables. The findings suggest that policies should be implemented to increase the role hydropower in the energy mix for sustainable economic growth in the country.
Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu28 citations 28 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2013 Netherlands, Netherlands, Netherlands, Netherlands, ItalyPublisher:Elsevier BV Lopes Ferreira, HM (Helder); Garde, R; Fulli, G (Gianluca); Kling, WL (Wil); Peças Lopes, JA (João);handle: 11583/2570345
In the current situation with the unprecedented deployment of clean technologies for electricity generation, it is natural to expect that storage will play an important role in electricity networks. This paper provides a qualitative methodology to select the appropriate technology or mix of technologies for different applications. The multiple comparisons according to different characteristics distinguish this paper from others about energy storage systems. Firstly, the different technologies available for energy storage, as discussed in the literature, are described and compared. The characteristics of the technologies are explained, including their current availability. In order to gain a better perspective, availability is cross-compared with maturity level. Moreover, information such as ratings, energy density, durability and costs is provided in table and graphic format for a straightforward comparison. Additionally, the different electric grid applications of energy storage technologies are described and categorised. For each of the categories, we describe the available technologies, both mature and potential. Finally, methods for connecting storage technologies are discussed.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 383 citations 383 popularity Top 0.1% influence Top 1% impulse Top 0.1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2013 Netherlands, Netherlands, Netherlands, Netherlands, ItalyPublisher:Elsevier BV Lopes Ferreira, HM (Helder); Garde, R; Fulli, G (Gianluca); Kling, WL (Wil); Peças Lopes, JA (João);handle: 11583/2570345
In the current situation with the unprecedented deployment of clean technologies for electricity generation, it is natural to expect that storage will play an important role in electricity networks. This paper provides a qualitative methodology to select the appropriate technology or mix of technologies for different applications. The multiple comparisons according to different characteristics distinguish this paper from others about energy storage systems. Firstly, the different technologies available for energy storage, as discussed in the literature, are described and compared. The characteristics of the technologies are explained, including their current availability. In order to gain a better perspective, availability is cross-compared with maturity level. Moreover, information such as ratings, energy density, durability and costs is provided in table and graphic format for a straightforward comparison. Additionally, the different electric grid applications of energy storage technologies are described and categorised. For each of the categories, we describe the available technologies, both mature and potential. Finally, methods for connecting storage technologies are discussed.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 383 citations 383 popularity Top 0.1% influence Top 1% impulse Top 0.1% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2013.02.037&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Canada, France, CanadaPublisher:Elsevier BV Boukenoui, Rachid; Ghanes, Malek; Barbot, Jean-Pierre; Bradai, Rafik; Mellit, Adel; Salhi, Hassen;This paper presents different Maximum Power Point Tracking (MPPT) methods belonging to different classes as well as two overviews. The first was about the procedures used in the test and evaluation of MPPTs. The second is an overview of Fuzzy Logic Controller (FLC) MPPTs and improved MPPTs. Conventional MPPTs such as Perturb and Observe (P&O), Hill Climbing (HC) and Incremental Conductance (InCond); Improved MPPTs (are the modified versions of conventional MPPTs) such as Improved Incremental Conductance (Improved-InCond) and intelligent MPPTs such as FLC have been implemented and tested under two different levels of irradiance and temperature. A detailed description about the hardware and software implementation platforms (designed and built in our laboratory) is provided. Based on measured data, the MPPTs under consideration have been evaluated and compared in terms of different criteria, showing the advantages and disadvantages of each one. The comparison results showed that Improved-InCond gives a fast convergence to the MPP(Maximum Power Point). Whereas, FLC is able to adapt to the variation of irradiance and temperature levels. Thereby, a good performance is obtained wherein the MPP is reached in a short time as well as the power ripples are very small.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu45 citations 45 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Canada, France, CanadaPublisher:Elsevier BV Boukenoui, Rachid; Ghanes, Malek; Barbot, Jean-Pierre; Bradai, Rafik; Mellit, Adel; Salhi, Hassen;This paper presents different Maximum Power Point Tracking (MPPT) methods belonging to different classes as well as two overviews. The first was about the procedures used in the test and evaluation of MPPTs. The second is an overview of Fuzzy Logic Controller (FLC) MPPTs and improved MPPTs. Conventional MPPTs such as Perturb and Observe (P&O), Hill Climbing (HC) and Incremental Conductance (InCond); Improved MPPTs (are the modified versions of conventional MPPTs) such as Improved Incremental Conductance (Improved-InCond) and intelligent MPPTs such as FLC have been implemented and tested under two different levels of irradiance and temperature. A detailed description about the hardware and software implementation platforms (designed and built in our laboratory) is provided. Based on measured data, the MPPTs under consideration have been evaluated and compared in terms of different criteria, showing the advantages and disadvantages of each one. The comparison results showed that Improved-InCond gives a fast convergence to the MPP(Maximum Power Point). Whereas, FLC is able to adapt to the variation of irradiance and temperature levels. Thereby, a good performance is obtained wherein the MPP is reached in a short time as well as the power ripples are very small.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu45 citations 45 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverUniversité de Nantes: HAL-UNIV-NANTESArticle . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.05.087&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal , Other literature type 2019 FrancePublisher:Elsevier BV Funded by:ANR | FEMANR| FEMAuthors: Thiébaut, Maxime; Sentchev, Alexei; Bailly Du Bois, Pascal;Abstract Tidal circulation and tidal stream resource in Alderney Race (Raz Blanchard) were assessed by using a towed acoustic Doppler current profiler (ADCP) system and tidal modeling. Optimal Interpolation (OI) was applied to process the underway velocity measurements recorded at neap tide flood and ebb flow. The interpolation technique allows reconstructing space-time evolution of the velocity field within the domain during surveying periods. The method employs velocity covariances derived from numerical simulations by a 2D hydrodynamic model MARS. Model covariances are utilized by the OI algorithm to obtain the most likely evolution of the velocity field under the constraints provided by the ADCP observations and their error statistics. The resulting velocity fields were used for assessing the tidal stream resource at site. The largest overall difference between the kinetic power density derived from simulated and interpolated velocity fields was found for ebb tide. Model simulations constrained by velocity measurements demonstrated a significant (up to 30%) decrease of power available in the flow. A significant change in spatial pattern of power density distribution was also identified. It is demonstrated that by merging high resolution velocity measurements at tidal energy site with modeling the tidal stream potential estimation becomes more accurate.
Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 22 citations 22 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal , Other literature type 2019 FrancePublisher:Elsevier BV Funded by:ANR | FEMANR| FEMAuthors: Thiébaut, Maxime; Sentchev, Alexei; Bailly Du Bois, Pascal;Abstract Tidal circulation and tidal stream resource in Alderney Race (Raz Blanchard) were assessed by using a towed acoustic Doppler current profiler (ADCP) system and tidal modeling. Optimal Interpolation (OI) was applied to process the underway velocity measurements recorded at neap tide flood and ebb flow. The interpolation technique allows reconstructing space-time evolution of the velocity field within the domain during surveying periods. The method employs velocity covariances derived from numerical simulations by a 2D hydrodynamic model MARS. Model covariances are utilized by the OI algorithm to obtain the most likely evolution of the velocity field under the constraints provided by the ADCP observations and their error statistics. The resulting velocity fields were used for assessing the tidal stream resource at site. The largest overall difference between the kinetic power density derived from simulated and interpolated velocity fields was found for ebb tide. Model simulations constrained by velocity measurements demonstrated a significant (up to 30%) decrease of power available in the flow. A significant change in spatial pattern of power density distribution was also identified. It is demonstrated that by merging high resolution velocity measurements at tidal energy site with modeling the tidal stream potential estimation becomes more accurate.
Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 22 citations 22 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Hyper Article en Lig... arrow_drop_down Institut national des sciences de l'Univers: HAL-INSUArticle . 2019License: CC BY NC NDFull-Text: https://hal.science/hal-02336285Data sources: Bielefeld Academic Search Engine (BASE)HAL - Université de LilleArticle . 2019License: CC BY NC NDData sources: HAL - Université de LilleArchiMer - Institutional Archive of IfremerOther literature type . 2019Data sources: ArchiMer - Institutional Archive of IfremerAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2019.04.171&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, ItalyPublisher:Elsevier BV Funded by:EC | INNOSTORAGE, EC | INPATH-TESEC| INNOSTORAGE ,EC| INPATH-TESDomenico Mazzeo; Giuseppe Oliveti; Alvaro de Gracia; Julià Coma; Aran Solé; Luisa F. Cabeza;handle: 10459.1/60248 , 20.500.11770/270333 , 2117/112028
Phase change materials (PCM) are used in many industrial and residential applications for their advantageous characteristic of high capacity of latent thermal storage by means of an isothermal process. In this context, it is very useful to have predictive mathematical models for the analysis of the thermal performance and for the thermal design of these layers. In this work, an experimental validation of an analytical model that resolves the steady periodic heat transfer problem in a finite layer of PCM is presented. The experimental investigation was conducted employing a PCM with thermophysical and thermochemical behavior very close to those hypothesized in the formulation of the analytical model. For the evaluation of the thermophysical properties of the PCM sample used, an experimental procedure created by the authors was employed. In all tests realized in a sinusoidal and non-sinusoidal periodic regime, the comparison between the measured and calculated trends of the temperature at different sample heights and of the surface heat fluxes show an excellent agreement. Moreover, also having verified the analytical total stored energy, the analytical model constitutes a valid instrument for the evaluation of the latent and sensible contribution and the trend in time of the position of the bi-phase interface. Peer Reviewed
Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 37 citations 37 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
visibility 42visibility views 42 download downloads 131 Powered bymore_vert Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 Spain, ItalyPublisher:Elsevier BV Funded by:EC | INNOSTORAGE, EC | INPATH-TESEC| INNOSTORAGE ,EC| INPATH-TESDomenico Mazzeo; Giuseppe Oliveti; Alvaro de Gracia; Julià Coma; Aran Solé; Luisa F. Cabeza;handle: 10459.1/60248 , 20.500.11770/270333 , 2117/112028
Phase change materials (PCM) are used in many industrial and residential applications for their advantageous characteristic of high capacity of latent thermal storage by means of an isothermal process. In this context, it is very useful to have predictive mathematical models for the analysis of the thermal performance and for the thermal design of these layers. In this work, an experimental validation of an analytical model that resolves the steady periodic heat transfer problem in a finite layer of PCM is presented. The experimental investigation was conducted employing a PCM with thermophysical and thermochemical behavior very close to those hypothesized in the formulation of the analytical model. For the evaluation of the thermophysical properties of the PCM sample used, an experimental procedure created by the authors was employed. In all tests realized in a sinusoidal and non-sinusoidal periodic regime, the comparison between the measured and calculated trends of the temperature at different sample heights and of the surface heat fluxes show an excellent agreement. Moreover, also having verified the analytical total stored energy, the analytical model constitutes a valid instrument for the evaluation of the latent and sensible contribution and the trend in time of the position of the bi-phase interface. Peer Reviewed
Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 37 citations 37 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
visibility 42visibility views 42 download downloads 131 Powered bymore_vert Universitat Politècn... arrow_drop_down Universitat Politècnica de Catalunya, BarcelonaTech: UPCommons - Global access to UPC knowledgeArticle . 2017License: CC BY NC NDFull-Text: http://hdl.handle.net/2117/112028Data sources: Bielefeld Academic Search Engine (BASE)Recolector de Ciencia Abierta, RECOLECTAArticle . 2017 . Peer-reviewedLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleLicense: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticleData sources: Recolector de Ciencia Abierta, RECOLECTARecolector de Ciencia Abierta, RECOLECTAArticle . 2017License: CC BY NC NDData sources: Recolector de Ciencia Abierta, RECOLECTAUPCommons. Portal del coneixement obert de la UPCArticle . 2017License: CC BY NC NDData sources: UPCommons. Portal del coneixement obert de la UPCResearch Repository of CataloniaArticleLicense: CC BY NC NDData sources: Research Repository of CataloniaRepositori Institucional de la Universitat Jaume IArticle . 2017Data sources: Repositori Institucional de la Universitat Jaume IArchivio Istituzionale dell'Università della CalabriaArticle . 2017Data sources: Archivio Istituzionale dell'Università della CalabriaAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.045&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 ItalyPublisher:Elsevier BV Paweł Ocłon; Monika Rerak; Ravipudi Venkata Rao; Piotr Cisek; Andrea Vallati; Dariusz Jakubek; Bartosz Rozegnał;handle: 11573/1451232
Abstract This paper presents a modified Jaya algorithm (MJaya) for optimizing the material costs and electric-thermal performance of an Underground Power Cable System (UPCS). Three power cables arranged in flat formation are considered. Three XLPE high voltage cables are situated in the thermal backfill layer for ensuring the optimal thermal performance of the cable system. The cable backfill dimensions, cable backfill material, and cable conductor area are selected as design variables in the optimization problem. In the study, the Finite Element Method model is validated experimentally. The Particle Swarm Optimization (PSO), Jaya, and MJaya algorithms are used for multiobjective optimization in order to design a cable system in such a way to minimize the cable backfill costs and maximize the allowable electric current flowing through the cables. For the case study, calculations performed using the Jaya algorithm indicated 1.7 mln Euro cable system costs while cable ampacity is equal to I = 1460 A. The calculations are performed for the objective function values equal to w1 = 0.5 and w2 = 0.5. Such an optimization parameters set allow obtaining low costs of UPCS alongside with reasonable cable line ampacity. What is more, the results of the optimization obtained by Jaya, MJaya, and PSO algorithms are compared. Therefore, Coverage and Hypervolume metrics are incorporated. It is concluded that both the Jaya and MJaya algorithms performed better when compared to the PSO algorithm.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 30 citations 30 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021 ItalyPublisher:Elsevier BV Paweł Ocłon; Monika Rerak; Ravipudi Venkata Rao; Piotr Cisek; Andrea Vallati; Dariusz Jakubek; Bartosz Rozegnał;handle: 11573/1451232
Abstract This paper presents a modified Jaya algorithm (MJaya) for optimizing the material costs and electric-thermal performance of an Underground Power Cable System (UPCS). Three power cables arranged in flat formation are considered. Three XLPE high voltage cables are situated in the thermal backfill layer for ensuring the optimal thermal performance of the cable system. The cable backfill dimensions, cable backfill material, and cable conductor area are selected as design variables in the optimization problem. In the study, the Finite Element Method model is validated experimentally. The Particle Swarm Optimization (PSO), Jaya, and MJaya algorithms are used for multiobjective optimization in order to design a cable system in such a way to minimize the cable backfill costs and maximize the allowable electric current flowing through the cables. For the case study, calculations performed using the Jaya algorithm indicated 1.7 mln Euro cable system costs while cable ampacity is equal to I = 1460 A. The calculations are performed for the objective function values equal to w1 = 0.5 and w2 = 0.5. Such an optimization parameters set allow obtaining low costs of UPCS alongside with reasonable cable line ampacity. What is more, the results of the optimization obtained by Jaya, MJaya, and PSO algorithms are compared. Therefore, Coverage and Hypervolume metrics are incorporated. It is concluded that both the Jaya and MJaya algorithms performed better when compared to the PSO algorithm.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 30 citations 30 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2020.119089&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004Publisher:Elsevier BV A. Jamali; M. Kouhila; Ali Idlimam; Mostafa Mahrouz; Siham Lahsasni;Abstract This paper presents the thin layer convective solar drying and mathematical modeling of prickly pear peel. For these purposes, an indirect forced convection solar dryer consisting of a solar air collector, an auxiliary heater, a circulation fan and a drying cabinet is used for drying experiments. Moreover, the prickly pear peel is sufficiently dried in the ranges of 32 to 36 °C of ambient air temperature, 50 to 60 °C of drying air temperature, 23 to 34% of relative humidity, 0.0277 to 0.0833 m3/s of drying air flow rate and 200 to 950 W/m2 of daily solar radiation. The experimental drying curves show only a falling drying rate period. The main factor in controlling the drying rate was found to be the drying air temperature. The drying rate equation is determined empirically from the characteristic drying curve. Also, the experimental drying curves obtained were fitted to a number of mathematical models. The Midilli–Kucuk drying model was found to satisfactorily describe the solar drying curves of prickly pear peel with a correlation coefficient (r) of 0.9998 and chi-square (χ2) of 4.6572 10−5.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu111 citations 111 popularity Top 1% influence Top 1% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2004Publisher:Elsevier BV A. Jamali; M. Kouhila; Ali Idlimam; Mostafa Mahrouz; Siham Lahsasni;Abstract This paper presents the thin layer convective solar drying and mathematical modeling of prickly pear peel. For these purposes, an indirect forced convection solar dryer consisting of a solar air collector, an auxiliary heater, a circulation fan and a drying cabinet is used for drying experiments. Moreover, the prickly pear peel is sufficiently dried in the ranges of 32 to 36 °C of ambient air temperature, 50 to 60 °C of drying air temperature, 23 to 34% of relative humidity, 0.0277 to 0.0833 m3/s of drying air flow rate and 200 to 950 W/m2 of daily solar radiation. The experimental drying curves show only a falling drying rate period. The main factor in controlling the drying rate was found to be the drying air temperature. The drying rate equation is determined empirically from the characteristic drying curve. Also, the experimental drying curves obtained were fitted to a number of mathematical models. The Midilli–Kucuk drying model was found to satisfactorily describe the solar drying curves of prickly pear peel with a correlation coefficient (r) of 0.9998 and chi-square (χ2) of 4.6572 10−5.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu111 citations 111 popularity Top 1% influence Top 1% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2003.08.009&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 France, France, France, France, ItalyPublisher:Elsevier BV Funded by:EC | ERANETMEDEC| ERANETMEDHout, Mohamad; Ghaddar, Nesreen; Ghali, Kamel; Ismail, Nagham; Simonetti, Marco; Fracastoro, Giovanni Vincenzo; Virgone, Joseph; Zoughaib, Assaad;handle: 11583/2704030
A novel transport model is developed for a space conditioned by a cooled liquid desiccant dehumidification membrane ceiling (LDMC-C) and displacement ventilation DV in which the space is divided into three zones: an occupied cool with fresh air zone; an upper recirculation zone; and a ceiling adjacent boundary layer zone where the air is drawn at the exhaust grill. The adjacent air boundary layer at the ceiling membrane predicted the latent and sensible heat transfer to the desiccant solution. The boundary model was validated experimentally in a climatic chamber. The developed model predicted of the LDMC-C/DV system operational parameters such as the supply flow rate and temperature and the liquid desiccant concentration, flow rate, and inlet temperature that meet thermal comfort and air quality requirements. Extensive simulations were performed on a typical office load of 75 W/m2 to generate design charts of the system for three DV supply air temperatures of 18, 20, and 22 °C to identify the appropriate DV flow rate and inlet desiccant (CaCl2) solution temperature that provide comfort and air quality and ensures that condensation is unlikely to occur. The LDMC sensible and latent load removal from the space load is directly read off the charts.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017 France, France, France, France, ItalyPublisher:Elsevier BV Funded by:EC | ERANETMEDEC| ERANETMEDHout, Mohamad; Ghaddar, Nesreen; Ghali, Kamel; Ismail, Nagham; Simonetti, Marco; Fracastoro, Giovanni Vincenzo; Virgone, Joseph; Zoughaib, Assaad;handle: 11583/2704030
A novel transport model is developed for a space conditioned by a cooled liquid desiccant dehumidification membrane ceiling (LDMC-C) and displacement ventilation DV in which the space is divided into three zones: an occupied cool with fresh air zone; an upper recirculation zone; and a ceiling adjacent boundary layer zone where the air is drawn at the exhaust grill. The adjacent air boundary layer at the ceiling membrane predicted the latent and sensible heat transfer to the desiccant solution. The boundary model was validated experimentally in a climatic chamber. The developed model predicted of the LDMC-C/DV system operational parameters such as the supply flow rate and temperature and the liquid desiccant concentration, flow rate, and inlet temperature that meet thermal comfort and air quality requirements. Extensive simulations were performed on a typical office load of 75 W/m2 to generate design charts of the system for three DV supply air temperatures of 18, 20, and 22 °C to identify the appropriate DV flow rate and inlet desiccant (CaCl2) solution temperature that provide comfort and air quality and ensures that condensation is unlikely to occur. The LDMC sensible and latent load removal from the space load is directly read off the charts.
INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu24 citations 24 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert INRIA a CCSD electro... arrow_drop_down INRIA a CCSD electronic archive serverArticle . 2017Data sources: INRIA a CCSD electronic archive serverMINES ParisTech: Open Archive (HAL)Article . 2017Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2017.08.046&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1999 ItalyPublisher:Elsevier BV Authors: SCHIBUOLA, LUIGI;handle: 11578/732
Abstract A total heat recovery system performances are analysed by monitoring building–plant system long term behaviour. Some of the installed chillers offer in fact the possibility of a total recovery of the heat rejected by condenser. The results are very satisfactory both in energy and economic–financial terms. The experimental test takes advantage of the supervisor just existing in the building. Therefore it is an example of how these control systems can be used not only for safety and management needs, but also for a detailed performance analysis able to permit an easy simulation of the effects of different design and control options.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu6 citations 6 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 1999 ItalyPublisher:Elsevier BV Authors: SCHIBUOLA, LUIGI;handle: 11578/732
Abstract A total heat recovery system performances are analysed by monitoring building–plant system long term behaviour. Some of the installed chillers offer in fact the possibility of a total recovery of the heat rejected by condenser. The results are very satisfactory both in energy and economic–financial terms. The experimental test takes advantage of the supervisor just existing in the building. Therefore it is an example of how these control systems can be used not only for safety and management needs, but also for a detailed performance analysis able to permit an easy simulation of the effects of different design and control options.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu6 citations 6 popularity Average influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/s0360-5442(98)00100-5&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006 ItalyPublisher:Elsevier BV BIANCHI, MICHELE; Cherubini F.; DE PASCALE, ANDREA; PERETTO, ANTONIO; Elmegaard B.;handle: 11585/36216
The availability of wet biomass as waste from a lot of industrial processes, from agriculture and farms and the need to meet the environmental standards force to investigate all options in order to dispose this waste. The possible treatments usually strongly depend on biomass characteristics, namely water content, density, organic content, heating value, etc. In particular, some of these wastes can be burnt in special plants, using them as energy supply for different processes. The study carried out with this paper is concerned with the promising utilization of the organic wastes from an existing poultry industry as fuel. Different plant configurations have been considered in order to make use of the oil and of the meat and bone meal, which are the by-products of the chicken cooking process. In particular, the process plant can be integrated with an energy supply plant, which can consist of an indirectly fired gas turbine. Moreover, a steam turbine plant or a simplified system for the supply of the only technological steam are investigated and compared. Thermodynamic and economic analysis have been carried out for the examined configurations in order to outline the basic differences in terms of energy savings/production and of return of the investments.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu21 citations 21 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2006 ItalyPublisher:Elsevier BV BIANCHI, MICHELE; Cherubini F.; DE PASCALE, ANDREA; PERETTO, ANTONIO; Elmegaard B.;handle: 11585/36216
The availability of wet biomass as waste from a lot of industrial processes, from agriculture and farms and the need to meet the environmental standards force to investigate all options in order to dispose this waste. The possible treatments usually strongly depend on biomass characteristics, namely water content, density, organic content, heating value, etc. In particular, some of these wastes can be burnt in special plants, using them as energy supply for different processes. The study carried out with this paper is concerned with the promising utilization of the organic wastes from an existing poultry industry as fuel. Different plant configurations have been considered in order to make use of the oil and of the meat and bone meal, which are the by-products of the chicken cooking process. In particular, the process plant can be integrated with an energy supply plant, which can consist of an indirectly fired gas turbine. Moreover, a steam turbine plant or a simplified system for the supply of the only technological steam are investigated and compared. Thermodynamic and economic analysis have been carried out for the examined configurations in order to outline the basic differences in terms of energy savings/production and of return of the investments.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu21 citations 21 popularity Top 10% influence Top 10% impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2005.05.028&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 MalaysiaPublisher:Elsevier BV Authors: Sakiru Adebola Solarin; Muhammad Shahbaz; Shawkat Hammoudeh;Abstract This paper examines the relationship between hydroelectricity consumption and economic growth in China, while controlling for fossil fuel consumption, financial development, capital, institutional quality and globalization and its components for the period, 1970–2014. We have employed the Bayer and Hanck, (2013) combined cointegration test to examine the long-run relationships between those variables as well as the autoregressive distributed lag method with structural breaks as a robustness check. The empirical findings demonstrate a long-run relationship between those variables. Hydroelectricity consumption, fossil fuel consumption, capital, financial development and globalization and its components have a positive influence on GDP in China. The findings also provide predominant evidence on the long-run feedback hypothesis between the variables. The findings suggest that policies should be implemented to increase the role hydropower in the energy mix for sustainable economic growth in the country.
Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu28 citations 28 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019 MalaysiaPublisher:Elsevier BV Authors: Sakiru Adebola Solarin; Muhammad Shahbaz; Shawkat Hammoudeh;Abstract This paper examines the relationship between hydroelectricity consumption and economic growth in China, while controlling for fossil fuel consumption, financial development, capital, institutional quality and globalization and its components for the period, 1970–2014. We have employed the Bayer and Hanck, (2013) combined cointegration test to examine the long-run relationships between those variables as well as the autoregressive distributed lag method with structural breaks as a robustness check. The empirical findings demonstrate a long-run relationship between those variables. Hydroelectricity consumption, fossil fuel consumption, capital, financial development and globalization and its components have a positive influence on GDP in China. The findings also provide predominant evidence on the long-run feedback hypothesis between the variables. The findings suggest that policies should be implemented to increase the role hydropower in the energy mix for sustainable economic growth in the country.
Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu28 citations 28 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert Energy arrow_drop_down Multimedia University, Malaysia: SHDL@MMU Digital RepositoryArticle . 2019Data sources: Bielefeld Academic Search Engine (BASE)All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2018.11.061&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu