- home
- Search
- Energy Research
- 2016-2025
- other engineering and technologies
- US
- IN
- GB
- Energy Research
- 2016-2025
- other engineering and technologies
- US
- IN
- GB
description Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Springer Science and Business Media LLC Authors: Vikram Kumar Kamboj; Ashutosh Bhadoria;In order to achieve paramount economy, hybrid renewable energy sources are gaining importance, as renewable sources are costless. Over the past few years wind energy incorporation drew more consideration in the electricity market, as wind power took an affirmative role in energy saving as well as sinking emission pollutants. Recently developed Grey wolf optimizer (GWO) algorithm has conspicuous behavior for verdicting global optima, without getting ensnared in premature convergence. In the proposed research the exploitation phase of the grey wolf optimizer has been further improved using random exploratory search algorithm, which uses perturbed solutions vectors along with previously generated solution vectors. The paper presents a hybrid version of Grey Wolf Optimizer algorithm combined with random exploratory search algorithm (hGWO-RES) for the solution of combinatorial scheduling and dispatch problem of electric power systems. To validate the feasibility of the algorithm, the proposed algorithm has been tested on 23 benchmark problems. To verify the feasibility and efficacy of operation of proposed algorithm on generation scheduling and dispatch of electric power systems, small and medium scale power systems consisting of 7-, 10-, 19-, 20- and 40-generating units systems taken into consideration. Commitment and scheduling pattern has been evaluated with and without wind integration and it has been experimentally founded that proposed hybrid algorithm provides superior solution as compared to other recently reported meta-heuristics search algorithms.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10489-018-1325-9&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 32 citations 32 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10489-018-1325-9&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Science Publishing Corporation Authors: H Sreepathy; C V S Chaitanya; S Nandish;With the extensive growth in technology, healthcare sector has benefitted a lot recently. Looking into the academic research and validation in the area of medical image processing and visualization, many platforms and the open-source resources are available. Insight toolkit (ITK) and visualization toolkit (VTK) are extensively used for medical image processing and 3D visualization respectively. Resources used to develop an application using ITK-VTK and same resources be used to deliver it to the users such as, clinicians, doctors etc. This can be achieved by using respective hardware and the infrastructure. In the proposed article, the infrastructure and resource used to build and deploy the application and remote access given to the users are elucidated.
International Journa... arrow_drop_down International Journal of Engineering & TechnologyArticle . 2018 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.14419/ijet.v7i3.1.17080&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Engineering & TechnologyArticle . 2018 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.14419/ijet.v7i3.1.17080&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Other literature type 2021Publisher:IEEE Yicheng Zhang; Xinyi Jiang; Da Lin; Zhifeng Du; Jian Chen;The path congestion and communication risks of electric power communication network have emerged as the carried businesses are becoming more and more heavy. In this paper, a multi-objective optimization method for power communication network routing considering the importance of the carried businesses is proposed to reduce load imbalance and transmission risk. Firstly, information entropy is introduced as the objective of communication network load balancing optimization. And a risk assessment model for power communication network nodes and links is established. Then fuzzy membership functions are adopted to singularize the two objectives to jointly optimize path congestion and communication risks. The device nodes are dynamically divided according to the carried businesses to pursue the global optimization of the power communication network in which the Yen's algorithm is adopted. Finally, this paper uses the IEEE 30-bus communication network to carry out case simulations and analyzes the proposed method to verify the effectiveness and feasibility.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/aeees51875.2021.9403042&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/aeees51875.2021.9403042&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:MDPI AG Lixiao Li; Yizhuo Zhou; Haifeng Wang; Haijun Zhou; Xuhui He; Teng Wu;doi: 10.3390/app9245385
Wind characteristics (e.g., mean wind speed, gust factor, turbulence intensity and integral scale, etc.) are quite scattered in different measurement conditions, especially during typhoon and/or hurricane processes, which results in the structural engineer ambiguously determining the wind parameters in wind-resistant design of buildings and structures in cyclone-prone regions. In tropical cyclones (including typhoons and hurricanes), the inconsistent wind characteristics may be in part ascribed to the complex flow structure with the coexistence of both mechanical and convective turbulence in the boundary layer of tropical cyclones. Another significant contribution to the scattered wind characteristics is due to various measurement conditions (e.g., terrain exposure and height) and data processing schemes (e.g., averaging time). The removal of the inconsistency in the field-measurement system may offer a more rational comparison of measured wind data from various observation platforms, and hence facilitates a better identification scheme of the wind characteristics to guide the urban planning design and wind-resistant design of buildings and structures. In this study, an analytical framework was firstly proposed to eliminate the potential observation-related effects in wind characteristics and then the wind characteristics of seven field measured tropical cyclones (four typhoons and three hurricanes) were comparatively investigated. Specifically, field measurements of wind characteristics were converted to a standard reference station with a roughness length of 0.03 m, observation duration of 10 min for mean wind and averaging time of 3 s for gusty wind at a 10 m height. The differences of the measured wind characteristics between the typhoons and hurricanes were highlighted. The standardized turbulent wind characteristics under the analytical framework for typhoons and hurricanes were compared with the corresponding recommendations in standard of American Society of Civil Engineers (ASCE 7-10) and Architectural Institute of Japan Recommendations for Loads on Buildings (AIJ-RLB-2004).
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/app9245385&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 11 citations 11 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/app9245385&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:TIB Open Publishing Luis F. González-Portillo; Victor Soria-Alcaide; Rubén Abbas; Kevin Albrecht; Clifford Ho; Brantley Mills;Particle receivers are gaining importance in the field of Concentrating Solar Power (CSP) due to the high temperature that particles can achieve without degradation. Several researchers are studying the potential of this technology by means of system analyses, which need simple and light models of the system. This study presents two simple models for the particle receiver. The simplest model is a correlation obtained by fitting the results calculated with a more complex receiver model simulated in CFD. The other model is a 1D model, which is benchmarked against the same CFD results. Although both models achieve high coefficient of determination, R2, when compared to CFD results, the 1D model seems to provide more accurate results (especially during sunsets and sunrises). Both models are integrated into a tecno-economic model developed in previous work. The LCOE obtained with the 1D model is between 7% and 10% greater than the one obtained with the correlation.
SolarPACES Conferenc... arrow_drop_down SolarPACES Conference ProceedingsArticle . 2024 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.52825/solarpaces.v1i.720&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert SolarPACES Conferenc... arrow_drop_down SolarPACES Conference ProceedingsArticle . 2024 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.52825/solarpaces.v1i.720&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:EDP Sciences Authors: Aman Mittal; G. Karuna;The study explores the enhancement of wind-solar hybrid microgrids via the use of Swarm Intelligence Algorithms (SIAs). It assesses the efficacy of these algorithms in efficiently managing renewable energy sources, load demands, and battery storage inside the microgrid system. An examination of actual data highlights the influence of environmental elements on the production of electricity, as seen by the diverse wind speeds resulting in power outputs that range from 15 kW at 4 m/s to 30 kW at 7 m/s. This underscores the clear and direct relationship between wind speed and the amount of power created. Likewise, solar irradiance levels demonstrate oscillations ranging from 500 W/m² to 800 W/m², therefore yielding power outputs that include a range of 15 kW to 24 kW, so illuminating the profound impact of solar irradiance on energy capture. The dynamic energy consumption patterns are exposed by the varying load demands, whereby the demand levels oscillate between 20 kW and 28 kW. This highlights the crucial significance of demand variability in determining energy needs. In addition, the data on battery storage reveals a range of charge levels, ranging from 25 kWh to 40 kWh, which underscores its pivotal function in the equilibrium of energy supply and consumption. When evaluating SIAs, it becomes evident that Particle Swarm Optimization (PSO) surpasses both Ant Colony Optimization (ACO) and Genetic Algorithms (GA) in obtaining an impressive 80% renewable energy penetration rate. PSO effectively reduces operating costs by 15%, demonstrating its exceptional proficiency in optimizing microgrid operations. This study provides valuable insights into the intricate interplay among environmental conditions, load demands, battery storage, and algorithmic optimization in wind-solar hybrid microgrids.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1051/matecconf/202439201187&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1051/matecconf/202439201187&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV A. Yerrayya; A. Nikunj; P. Francis Prashanth; S.R. Chakravarthy; Upendra Natarajan; R. Vinu;All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2022.123192&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu21 citations 21 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2022.123192&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:American Institute of Mathematical Sciences (AIMS) Dipak R. Swain; Sunita S. Biswal; Pravat Kumar Rout; P. K. Ray; R. K. Jena;<abstract> <p>The rising proportion of inverter-based renewable energy sources in current power systems has reduced the rotational inertia of overall microgrid systems. This may cause high-frequency fluctuations in the system leading to system instability. Several initiatives have been suggested concerning inertia emulation based on other integrated external energy sources, such as energy storage systems, to combat the ever-declining issue of inertia. Hence, to deal with the aforementioned issue, we suggest the development of an optimal fractional sliding mode control (FSMC)-based frequency stabilization strategy for an industrial hybrid microgrid. An explicit state-space industrial microgrids model comprised of several coordinated energy sources along with loads, storage systems, photovoltaic and wind farms, is considered. In addition to this, the impact of electric vehicles and batteries with adequate control of the state of charge was investigated due to their short regulation times and this helps to balance the power supply and demand that in turn brings the minimization of the frequency deviations. The performance of the FSMC controller is enhanced by setting optimal parameters by employing the tuning strategy based on an iterative teaching-learning-based optimizer (ITLBO). To justify the efficacy of the proposed controller, the simulated results were obtained under several system conditions by using a vehicle simulator in a MATLAB/Simulink environment. The results reveal the enhanced performance of the ITLBO optimized fractional sliding mode control to effectively damp the frequency oscillations and retain the frequency stability with robustness, quick damping, and reliability under different system conditions.</p> </abstract>
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3934/electreng.2023002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 3 citations 3 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3934/electreng.2023002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Article , Journal 2019Publisher:IEEE Jose Cordova-Garcia; Xin Wang; Dongliang Xie; Yue Zhao; Lei Zuo;The most severe failures in power grids are often characterized as cascading failures where an initial event triggers consequent failures all along the grid often leading to blackouts. Upon identifying a failure and its cascade potential, timely control actions should be performed by the grid operators to mitigate the effect of the cascade. These actions have to be delivered to one or more control devices, creating a dependency between the power grid and its control network. This paper examines the dependency of the operation of the power grid on the control network. Different from literature studies on failure control, our dependency model captures the impact of networking parameters. We formulate an algorithmic model that describes the impact of this dependency on cascade control. Based on this model, we propose an efficient cascade control algorithm using load shedding with consideration of delays in the communication network for power grids. Finally, we evaluate the impact of the power-communication network dependency with uncontrolled grids, ideal/simple control grids and our proposed control scheme. The results demonstrate that the proposed algorithm can significantly reduce the failure of power lines while sustaining larger power demand for users.
IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallhttps://doi.org/10.1109/pesgm4...Conference object . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefIEEE Transactions on Smart GridArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/pesgm40551.2019.8973695&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 28 citations 28 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallhttps://doi.org/10.1109/pesgm4...Conference object . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefIEEE Transactions on Smart GridArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/pesgm40551.2019.8973695&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2024Publisher:Institute of Electrical and Electronics Engineers (IEEE) Authors: Nilanjan Senroy; Abdul Saleem Mir;The use of superconducting magnetic energy storage (SMES) has been widely reported in the literature to mitigate various load frequency control (LFC) issues in a multi-area power system. Most of these are thyristor based SMES, employing proportional type controllers. In this paper, a supervisory adaptive model predictive control scheme (AMPC) is proposed for a voltage source converter based relatively small rating SMES for LFC application. The reference power command for the SMES is derived from the AMPC in such a manner that it effectively handles the operational constraints of the SMES system. A representative first-order system emulating the inner loop dynamics of the SMES chopper system, is tuned offline via genetic algorithm (GA) and is used to derive dynamic constraints for the cost function in AMPC. The effectiveness of the scheme is demonstrated through simulations.
IEEE Transactions on... arrow_drop_down IEEE Transactions on Power SystemsArticle . 2024 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2017.2720751&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 20 citations 20 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert IEEE Transactions on... arrow_drop_down IEEE Transactions on Power SystemsArticle . 2024 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2017.2720751&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Springer Science and Business Media LLC Authors: Vikram Kumar Kamboj; Ashutosh Bhadoria;In order to achieve paramount economy, hybrid renewable energy sources are gaining importance, as renewable sources are costless. Over the past few years wind energy incorporation drew more consideration in the electricity market, as wind power took an affirmative role in energy saving as well as sinking emission pollutants. Recently developed Grey wolf optimizer (GWO) algorithm has conspicuous behavior for verdicting global optima, without getting ensnared in premature convergence. In the proposed research the exploitation phase of the grey wolf optimizer has been further improved using random exploratory search algorithm, which uses perturbed solutions vectors along with previously generated solution vectors. The paper presents a hybrid version of Grey Wolf Optimizer algorithm combined with random exploratory search algorithm (hGWO-RES) for the solution of combinatorial scheduling and dispatch problem of electric power systems. To validate the feasibility of the algorithm, the proposed algorithm has been tested on 23 benchmark problems. To verify the feasibility and efficacy of operation of proposed algorithm on generation scheduling and dispatch of electric power systems, small and medium scale power systems consisting of 7-, 10-, 19-, 20- and 40-generating units systems taken into consideration. Commitment and scheduling pattern has been evaluated with and without wind integration and it has been experimentally founded that proposed hybrid algorithm provides superior solution as compared to other recently reported meta-heuristics search algorithms.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10489-018-1325-9&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 32 citations 32 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1007/s10489-018-1325-9&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Science Publishing Corporation Authors: H Sreepathy; C V S Chaitanya; S Nandish;With the extensive growth in technology, healthcare sector has benefitted a lot recently. Looking into the academic research and validation in the area of medical image processing and visualization, many platforms and the open-source resources are available. Insight toolkit (ITK) and visualization toolkit (VTK) are extensively used for medical image processing and 3D visualization respectively. Resources used to develop an application using ITK-VTK and same resources be used to deliver it to the users such as, clinicians, doctors etc. This can be achieved by using respective hardware and the infrastructure. In the proposed article, the infrastructure and resource used to build and deploy the application and remote access given to the users are elucidated.
International Journa... arrow_drop_down International Journal of Engineering & TechnologyArticle . 2018 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.14419/ijet.v7i3.1.17080&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 1 citations 1 popularity Average influence Average impulse Average Powered by BIP!
more_vert International Journa... arrow_drop_down International Journal of Engineering & TechnologyArticle . 2018 . Peer-reviewedData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.14419/ijet.v7i3.1.17080&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Other literature type 2021Publisher:IEEE Yicheng Zhang; Xinyi Jiang; Da Lin; Zhifeng Du; Jian Chen;The path congestion and communication risks of electric power communication network have emerged as the carried businesses are becoming more and more heavy. In this paper, a multi-objective optimization method for power communication network routing considering the importance of the carried businesses is proposed to reduce load imbalance and transmission risk. Firstly, information entropy is introduced as the objective of communication network load balancing optimization. And a risk assessment model for power communication network nodes and links is established. Then fuzzy membership functions are adopted to singularize the two objectives to jointly optimize path congestion and communication risks. The device nodes are dynamically divided according to the carried businesses to pursue the global optimization of the power communication network in which the Yen's algorithm is adopted. Finally, this paper uses the IEEE 30-bus communication network to carry out case simulations and analyzes the proposed method to verify the effectiveness and feasibility.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/aeees51875.2021.9403042&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/aeees51875.2021.9403042&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:MDPI AG Lixiao Li; Yizhuo Zhou; Haifeng Wang; Haijun Zhou; Xuhui He; Teng Wu;doi: 10.3390/app9245385
Wind characteristics (e.g., mean wind speed, gust factor, turbulence intensity and integral scale, etc.) are quite scattered in different measurement conditions, especially during typhoon and/or hurricane processes, which results in the structural engineer ambiguously determining the wind parameters in wind-resistant design of buildings and structures in cyclone-prone regions. In tropical cyclones (including typhoons and hurricanes), the inconsistent wind characteristics may be in part ascribed to the complex flow structure with the coexistence of both mechanical and convective turbulence in the boundary layer of tropical cyclones. Another significant contribution to the scattered wind characteristics is due to various measurement conditions (e.g., terrain exposure and height) and data processing schemes (e.g., averaging time). The removal of the inconsistency in the field-measurement system may offer a more rational comparison of measured wind data from various observation platforms, and hence facilitates a better identification scheme of the wind characteristics to guide the urban planning design and wind-resistant design of buildings and structures. In this study, an analytical framework was firstly proposed to eliminate the potential observation-related effects in wind characteristics and then the wind characteristics of seven field measured tropical cyclones (four typhoons and three hurricanes) were comparatively investigated. Specifically, field measurements of wind characteristics were converted to a standard reference station with a roughness length of 0.03 m, observation duration of 10 min for mean wind and averaging time of 3 s for gusty wind at a 10 m height. The differences of the measured wind characteristics between the typhoons and hurricanes were highlighted. The standardized turbulent wind characteristics under the analytical framework for typhoons and hurricanes were compared with the corresponding recommendations in standard of American Society of Civil Engineers (ASCE 7-10) and Architectural Institute of Japan Recommendations for Loads on Buildings (AIJ-RLB-2004).
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/app9245385&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 11 citations 11 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/app9245385&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:TIB Open Publishing Luis F. González-Portillo; Victor Soria-Alcaide; Rubén Abbas; Kevin Albrecht; Clifford Ho; Brantley Mills;Particle receivers are gaining importance in the field of Concentrating Solar Power (CSP) due to the high temperature that particles can achieve without degradation. Several researchers are studying the potential of this technology by means of system analyses, which need simple and light models of the system. This study presents two simple models for the particle receiver. The simplest model is a correlation obtained by fitting the results calculated with a more complex receiver model simulated in CFD. The other model is a 1D model, which is benchmarked against the same CFD results. Although both models achieve high coefficient of determination, R2, when compared to CFD results, the 1D model seems to provide more accurate results (especially during sunsets and sunrises). Both models are integrated into a tecno-economic model developed in previous work. The LCOE obtained with the 1D model is between 7% and 10% greater than the one obtained with the correlation.
SolarPACES Conferenc... arrow_drop_down SolarPACES Conference ProceedingsArticle . 2024 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.52825/solarpaces.v1i.720&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert SolarPACES Conferenc... arrow_drop_down SolarPACES Conference ProceedingsArticle . 2024 . Peer-reviewedLicense: CC BYData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.52825/solarpaces.v1i.720&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2024Publisher:EDP Sciences Authors: Aman Mittal; G. Karuna;The study explores the enhancement of wind-solar hybrid microgrids via the use of Swarm Intelligence Algorithms (SIAs). It assesses the efficacy of these algorithms in efficiently managing renewable energy sources, load demands, and battery storage inside the microgrid system. An examination of actual data highlights the influence of environmental elements on the production of electricity, as seen by the diverse wind speeds resulting in power outputs that range from 15 kW at 4 m/s to 30 kW at 7 m/s. This underscores the clear and direct relationship between wind speed and the amount of power created. Likewise, solar irradiance levels demonstrate oscillations ranging from 500 W/m² to 800 W/m², therefore yielding power outputs that include a range of 15 kW to 24 kW, so illuminating the profound impact of solar irradiance on energy capture. The dynamic energy consumption patterns are exposed by the varying load demands, whereby the demand levels oscillate between 20 kW and 28 kW. This highlights the crucial significance of demand variability in determining energy needs. In addition, the data on battery storage reveals a range of charge levels, ranging from 25 kWh to 40 kWh, which underscores its pivotal function in the equilibrium of energy supply and consumption. When evaluating SIAs, it becomes evident that Particle Swarm Optimization (PSO) surpasses both Ant Colony Optimization (ACO) and Genetic Algorithms (GA) in obtaining an impressive 80% renewable energy penetration rate. PSO effectively reduces operating costs by 15%, demonstrating its exceptional proficiency in optimizing microgrid operations. This study provides valuable insights into the intricate interplay among environmental conditions, load demands, battery storage, and algorithmic optimization in wind-solar hybrid microgrids.
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1051/matecconf/202439201187&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu0 citations 0 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1051/matecconf/202439201187&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:Elsevier BV A. Yerrayya; A. Nikunj; P. Francis Prashanth; S.R. Chakravarthy; Upendra Natarajan; R. Vinu;All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2022.123192&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu21 citations 21 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.energy.2022.123192&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article 2022Publisher:American Institute of Mathematical Sciences (AIMS) Dipak R. Swain; Sunita S. Biswal; Pravat Kumar Rout; P. K. Ray; R. K. Jena;<abstract> <p>The rising proportion of inverter-based renewable energy sources in current power systems has reduced the rotational inertia of overall microgrid systems. This may cause high-frequency fluctuations in the system leading to system instability. Several initiatives have been suggested concerning inertia emulation based on other integrated external energy sources, such as energy storage systems, to combat the ever-declining issue of inertia. Hence, to deal with the aforementioned issue, we suggest the development of an optimal fractional sliding mode control (FSMC)-based frequency stabilization strategy for an industrial hybrid microgrid. An explicit state-space industrial microgrids model comprised of several coordinated energy sources along with loads, storage systems, photovoltaic and wind farms, is considered. In addition to this, the impact of electric vehicles and batteries with adequate control of the state of charge was investigated due to their short regulation times and this helps to balance the power supply and demand that in turn brings the minimization of the frequency deviations. The performance of the FSMC controller is enhanced by setting optimal parameters by employing the tuning strategy based on an iterative teaching-learning-based optimizer (ITLBO). To justify the efficacy of the proposed controller, the simulated results were obtained under several system conditions by using a vehicle simulator in a MATLAB/Simulink environment. The results reveal the enhanced performance of the ITLBO optimized fractional sliding mode control to effectively damp the frequency oscillations and retain the frequency stability with robustness, quick damping, and reliability under different system conditions.</p> </abstract>
All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3934/electreng.2023002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 3 citations 3 popularity Average influence Average impulse Average Powered by BIP!
more_vert All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3934/electreng.2023002&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Conference object , Article , Journal 2019Publisher:IEEE Jose Cordova-Garcia; Xin Wang; Dongliang Xie; Yue Zhao; Lei Zuo;The most severe failures in power grids are often characterized as cascading failures where an initial event triggers consequent failures all along the grid often leading to blackouts. Upon identifying a failure and its cascade potential, timely control actions should be performed by the grid operators to mitigate the effect of the cascade. These actions have to be delivered to one or more control devices, creating a dependency between the power grid and its control network. This paper examines the dependency of the operation of the power grid on the control network. Different from literature studies on failure control, our dependency model captures the impact of networking parameters. We formulate an algorithmic model that describes the impact of this dependency on cascade control. Based on this model, we propose an efficient cascade control algorithm using load shedding with consideration of delays in the communication network for power grids. Finally, we evaluate the impact of the power-communication network dependency with uncontrolled grids, ideal/simple control grids and our proposed control scheme. The results demonstrate that the proposed algorithm can significantly reduce the failure of power lines while sustaining larger power demand for users.
IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallhttps://doi.org/10.1109/pesgm4...Conference object . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefIEEE Transactions on Smart GridArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/pesgm40551.2019.8973695&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routeshybrid 28 citations 28 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallhttps://doi.org/10.1109/pesgm4...Conference object . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefIEEE Transactions on Smart GridArticle . 2019 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/pesgm40551.2019.8973695&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2024Publisher:Institute of Electrical and Electronics Engineers (IEEE) Authors: Nilanjan Senroy; Abdul Saleem Mir;The use of superconducting magnetic energy storage (SMES) has been widely reported in the literature to mitigate various load frequency control (LFC) issues in a multi-area power system. Most of these are thyristor based SMES, employing proportional type controllers. In this paper, a supervisory adaptive model predictive control scheme (AMPC) is proposed for a voltage source converter based relatively small rating SMES for LFC application. The reference power command for the SMES is derived from the AMPC in such a manner that it effectively handles the operational constraints of the SMES system. A representative first-order system emulating the inner loop dynamics of the SMES chopper system, is tuned offline via genetic algorithm (GA) and is used to derive dynamic constraints for the cost function in AMPC. The effectiveness of the scheme is demonstrated through simulations.
IEEE Transactions on... arrow_drop_down IEEE Transactions on Power SystemsArticle . 2024 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2017.2720751&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 20 citations 20 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert IEEE Transactions on... arrow_drop_down IEEE Transactions on Power SystemsArticle . 2024 . Peer-reviewedLicense: IEEE CopyrightData sources: CrossrefAll Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tpwrs.2017.2720751&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu