- home
- Search
- Energy Research
- 2016-2025
- engineering and technology
- AU
- CA
- JP
- Energy Research
- 2016-2025
- engineering and technology
- AU
- CA
- JP
description Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Funded by:NSERCNSERCAuthors: Aashish Gaurav; Chau T.Q. Mai; Flora T. T. Ng; Stéphane Dumas;Production of biodiesel from yellow grease (waste cooking oil and waste animal fats) is fast emerging as a promising alternative to address the twin challenges before the biodiesel industry today-fluctuation in prices of vegetable oil and the food versus fuel debate. Yellow grease has a high percentage of free fatty acids (FFA) and proves to be an unsuitable feedstock for biodiesel production from commercially viable alkali-catalyzed production systems due to saponification problems.“Green” methodologies based on heterogeneous solid acid catalyzed reactions have the potential to simultaneously promote esterification and transesterification reactions of yellow grease to produce biodiesel without soap formation and offer easy catalyst separation without generation of toxic streams. This paper presents kinetic studies for the conversion of model yellow grease feeds to biodiesel using a heteropolyacid supported on alumina (HSiW/Al2O3) using a batch autoclave. Three model yellow grease feeds were prepared using canola oil with added FFA such as palmitic, oleic and linoleic acid. A pseudo homogeneous kinetic model for the parallel esterification and transesterification was developed. The rate constants and activation parameters for esterification and transesterification reactions for the model yellow grease feeds were determined. The rate constants for esterification are higher than the transesterification rate constants. The kinetic model was validated using the experimental biodiesel data obtained from processing a commercial yellow grease feed. The kinetic model could be used to design novel processes to convert various low-value waste oils, fats and non-food grade oils to sustainable biodiesel. Keywords: Yellow grease, Canola oil, Free fatty acids, Heteropolyacid, Kinetics for esterification and transesterification
Green Energy & E... arrow_drop_down Green Energy & EnvironmentArticle . 2019 . Peer-reviewedLicense: CC BY NC NDData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.gee.2019.03.004&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 72 citations 72 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Green Energy & E... arrow_drop_down Green Energy & EnvironmentArticle . 2019 . Peer-reviewedLicense: CC BY NC NDData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.gee.2019.03.004&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Elsevier BV Funded by:NSERCNSERCChunbao (Charles) Xu; Chunbao (Charles) Xu; Shanghuan Feng; Gang Chen; An Li; Zhongshun Yuan; Takashi Kuboki; Tao Shui; Hengfu Shui;Abstract In this study, crude cellulose derived from cornstalk, after bleaching, was used as raw material for the synthesis of sodium carboxymethyl cellulose (CMC) by reacting with the cellulose with NaOH and chloroacetic acid at 75 °C for 1.5 h. Effects of alkali dosage, concentration of chloroacetic acid on the physical and chemical properties of the CMC products were investigated. It was revealed that the reactants alkali reagent/chloroacetic acid/cellulose at the molar ratio of 4.6:2.8:1and 4:2.5:1, or at the molar ratio of NaOH/ClCH 2 COOH ≈1.6–1.64, resulted in CMC products of relatively high water solubility. The viscosity-average molecular weight M v of these two CMC products obtained at molar ratios of 4.0:2.5:1 and 4.6:2.8:1 is in the range of 1.94 × 10 4 –2.48 × 10 4 g mol −1 , and the average DS of the two products are 0.57 and 0.85, respectively. As the solute concentration is above 2 wt%, the viscosity of the CMC-water solution exhibits nonlinear (exponential) increasing with increasing the solute concentration (typical of non-Newton fluids).
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2017.06.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 74 citations 74 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2017.06.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Wiley Miyuki Sakakura; Yasuhiro Suzuki; Takayuki Yamamoto; Yuta Yamamoto; Munekazu Motoyama; Yasutoshi Iriyama;Interfacial resistance at electrode‐high Li+ conductive solid electrolytes must be reduced well to develop high‐power all‐solid‐state batteries using oxide‐based solid electrolytes (Ox‐SSBs). Herein, crystalline electrode films of LiCoO2 (LCO) are formed on a high Li+ conductive crystalline‐glass solid electrolyte sheet, Li1.3Al0.3Ti2(PO4)3 (LATP) (σ25 °C = 1 × 10−4 S cm−1), at room temperature by aerosol deposition (AD), and the effects of the annealing temperature on the interfacial resistivities (Rint) at the LCO/LATP are investigated. The Rint visibly increases by annealing over 500 °C with the growth of Co3O4 as a reactant. In contrast, Rint is reduced to ≈100 Ω cm2 by low‐temperature annealing at 250–350 °C due to superior contact through the structural rearrangement of an artificial metastable interface formed by the AD. These results are applied to bulk‐type Ox‐SSB, Li/Li7La3Zr2O12(LLZ)/LCO–LATP, and our best Ox‐SSB delivers a discharge capacity of 100 mA cm−2 at 100 °C.
Energy Technology arrow_drop_down Energy TechnologyArticle . 2021 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/ente.202001059&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 12 citations 12 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Energy Technology arrow_drop_down Energy TechnologyArticle . 2021 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/ente.202001059&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:MDPI AG Xingbo Yao; Bart J. Dewancker; Yuang Guo; Shuo Han; Juan Xu;doi: 10.3390/su12208687
China’s research on and specific implementation of energy saving for buildings are mainly concentrated in urban areas, but according to 2016 statistics, the rural population accounts for 42.65% of the total population, so rural housing has considerable energy-saving potential. However, the degree of attention to the energy consumption of rural houses needs to be improved. Regarding the research on and implementation of passive energy-saving strategies for residences, compared with centralized urban high-rise residences, rural residences mainly have independent courtyards, with a flexible layout and easier transformation. In this study, a system that uses the common cold lanes in traditional villages and buildings’ exterior walls was constructed, and the indoor spaces of courtyard buildings in southern Shaanxi were completely passively cooled in summer. This system can be completely separated from the supply of artificial energy by relying on the accumulation and buoyancy effects of air in patios and cold lanes and the hot-pressure ventilation in buildings to cool the buildings and greatly improve indoor ventilation efficiency. As the building is ventilated and cooled, the air wall formed in the system can effectively prevent direct contact between the outdoor and indoor temperatures and reduce the impact of thermal wall radiation on the interior. In previous studies on the passive design of courtyard houses, scholars considered the effect of thermal wall radiation on indoor temperature in simulations. Therefore, in this study, we also separately calculated whether to consider the difference between the situation with and without wall heat radiation (WHR) when simulating thermal conversion. The final results show that when the cooling system was adopted, the annual cooling load of the whole building was 4786.494 kW·h without WHR. However, with WHR, the cooling load reduction was 2989.128 kW·h, a difference of 1797.336 kW·h.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su12208687&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 13 citations 13 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su12208687&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Elsevier BV Funded by:NSERCNSERCZhongshun Yuan; Hongwei Li; Hongwei Li; Chunbao (Charles) Xu; Qin Wei;Abstract Bio-based polyurethane (BPU) foams were successfully prepared using hydrothermally liquefied wheat straw (WS) to substitute a mass fraction of up to 50% of polyols. Response surface methodology (RSM) based on central composite design (CCD) was employed to optimize four process parameters: NCO/OH molar ratio, loading of crosslinking agent (glycerol), loading of catalyst (a mixture of triethylene diamine, stannous octoate, and triethanolamine), and loading of blowing agent (water) for the maximum compression strength of the rigid BPU foams. With the quadratic orthogonal regression model, verified by experimentation, the maximum compression strength of approximately 180 kPa was obtained at the following optimal conditions: NCO/OH molar ratio of 1.24:1, glycerol addition of 12.11%, catalyst loading of 0.76%, and blowing agent addition of 1.31% in relation to the total mass of polyols. The BPU foam prepared at the optimal conditions exhibits good thermal conductivity (0.045 Wm−1K−1) and thermal stability, comparable to those of a reference foam prepared with 100% PPG400.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2018.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 41 citations 41 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2018.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint , Journal , Other literature type 2016Embargo end date: 01 Jan 2016Publisher:Institute of Electrical and Electronics Engineers (IEEE) Funded by:NSF | CPS: Medium: Collaborativ..., NSERCNSF| CPS: Medium: Collaborative Research: The Cyber-Physical Challenges of Transient Stability and Security in Power Grids ,NSERCAuthors: John W. Simpson-Porco; Francesco Bullo;arXiv: 1602.05632
The assessment of voltage stability margins is a promising direction for wide-area monitoring systems. Accurate monitoring architectures for long-term voltage instability are typically centralized and lack scalability, while completely decentralized approaches relying on local measurements tend towards inaccuracy. Here we present distributed linear algorithms for the online computation of voltage collapse sensitivity indices. The computations are collectively performed by processors embedded at each bus in the smart grid, using synchronized phasor measurements and communication of voltage phasors between neighboring buses. Our algorithms provably converge to the proper index values, as would be calculated using centralized information, but but do not require any central decision maker for coordination. Modifications of the algorithms to account for generator reactive power limits are discussed. We illustrate the effectiveness of our designs with a case study of the New England 39 bus system. 10 pages, submitted for publication
IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallIEEE Transactions on Smart GridArticle . 2016 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefhttps://dx.doi.org/10.48550/ar...Article . 2016License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tsg.2016.2533319&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 41 citations 41 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallIEEE Transactions on Smart GridArticle . 2016 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefhttps://dx.doi.org/10.48550/ar...Article . 2016License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tsg.2016.2533319&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV El-Bidairi, Kutaiba S; Duc Nguyen, Hung; Jayasinghe, S.D.G; Mahmoud, Thair S; Penesis, Irene;Microgrids are increasingly being used as a platform to integrate distributed generation such as renewable energy sources and (RESs) conventional sources in both grid-connected and isolated power systems. Due to the inherent intermittent nature of RESs, energy storage systems (ESSs) that can absorb fluctuations have become inevitable. Nevertheless, large capacities of ESSs increase the initial cost while small capacities lead to instabilities and increase in the cost of conventional fuels. Therefore, finding the optimal size of the ESS for a given application is essential for the reliable, efficient and economical operation of a microgrid. Once the battery size is decided, maintaining its energy at appropriate levels is essential to ensure stable and safe operation of the microgrid. This paper presents a novel expert fuzzy system - grey wolf optimization (FL-GWO) based intelligent meta-heuristic method for battery sizing and energy management. The proposed energy management operation is carried out by a Grey Wolf Optimiser (GWO) that is helped to set the membership functions and rules of the fuzzy logic expert system. The unit commitment (UC) issue, which is essential for the proper operation of the isolated microgrid, has been additionally considered in this paper. To verify the performance of the proposed method, results are compared with the rules-based method and traditional GWO algorithm. It has been proven from the results that the FL-GWO has a significant convergence property and capability to minimize the Levelized Cost Of Electricity (LCOE) by 14.13% and 24.15% compared with conventional GWO algorithm and rules-based method, respectively. The weather conditions for different climates is used to verify the performance of the intelligent energy management method under different operating scenarios. The results show that the intelligent online multi-objective energy management strategy is capable of managing a smooth power flow with the same optimal configuration in the isolated microgrid, minimising the fossil fuel utilisation and reducing the CO2 emission level.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversity of Tasmania: UTas ePrintsArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)Edith Cowan University (ECU, Australia): Research OnlineArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 115 citations 115 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversity of Tasmania: UTas ePrintsArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)Edith Cowan University (ECU, Australia): Research OnlineArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Elsevier BV Beibei Xu; Pengcheng Guo; Diyi Chen; Diyi Chen; Xingqi Luo; Paul Behrens; Wei Ye;Abstract Global hydropower growth continues to accelerate with 25% of total capacity installed in just the last 10 years. This accelerating expansion and the important storage facility hydropower means it is increasingly important to understand the reasons for operational failures. This is a challenge because the major reason for failures involves the complex interaction of hydraulic, mechanical and electric subsystems. Historically, reliability modelling has been split in two directions, focusing on different sub-systems, and has not yet been unified. Here these approaches are unified with a novel expression of unbalanced forces. This model with operational data are validated and the important modes of oscillation in the shaft are identified. Finally, the mechanism of the first-order oscillation mode exciting a second-order mode is presented. This integrated and accurate mathematical model is a major advance in the diagnosis and prediction of failures in hydropower operation.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.034&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 52 citations 52 popularity Top 10% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.034&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Ismail Adal Guiamel; Han Soo Lee;This study aims to identify potential hydropower sites and calculate the theoretical potential hydropower capacity based on watershed modelling of the Mindanao River Basin (MRB) in the Philippines for the sustainable development of a previously unstudied region. The Soil and Water Assessment Tool (SWAT) was applied to delineate the watershed of the MRB and simulate the river discharges with inputs from observed precipitation and global gridded precipitation datasets. Observed weather data, such as temperature, humidity, and solar radiation, from four meteorological stations in the Philippines were also used as inputs for SWAT modelling. Simulated discharges were calibrated at three river gauges on the Nituan, Libungan and Pulangi Rivers. However, due to limited river discharge records, model validations were conducted in proxy basins: the calibrated model parameters in river A were used in the watershed modelling of proxy river B. Of the delineated 107 sub-basins in the MRB watershed, only 33 were identified as having potential sites for hydropower development. These potential sub-basins hosted a total of 154 potential sites with an estimated monthly average power capacity of 5,551.35 MW for all 33 sub-basins. The estimated theoretical power capacity of 15,266.22 MW for all sites in the MRB is approximately equivalent to the Philippines’ total available power capacity in 2017 of 15,393 MW. These sites were classified into 16 mini-scale hydropower sites, 114 small-scale hydropower sites and 24 medium-scale hydropower sites based on the simulated river discharges and potential power capacities. Based on these results, hydropower development could be an alternative to strengthen the exploration of renewable energy resources and improve the energy situation in Mindanao; hydropower development could also have mitigation effects on frequent floods in flat, low-lying downstream areas.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.egyr.2020.04.025&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.egyr.2020.04.025&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Royal Society of Chemistry (RSC) Jia Li; Lixun Cheng; Fei Wang; Li Li; Yanming Wang; Song Dai; Yongxing Zhang; Xin-Yao Yu; Xin-Yao Yu;doi: 10.1039/c9se00770a
Mixed transition metal oxides with high theoretical capacity show great potential to replace carbonaceous anode materials in lithium-ion batteries.
Sustainable Energy &... arrow_drop_down Sustainable Energy & FuelsArticle . 2019 . Peer-reviewedLicense: Royal Society of Chemistry Licence to PublishData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1039/c9se00770a&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 9 citations 9 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Sustainable Energy &... arrow_drop_down Sustainable Energy & FuelsArticle . 2019 . Peer-reviewedLicense: Royal Society of Chemistry Licence to PublishData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1039/c9se00770a&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu
description Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Elsevier BV Funded by:NSERCNSERCAuthors: Aashish Gaurav; Chau T.Q. Mai; Flora T. T. Ng; Stéphane Dumas;Production of biodiesel from yellow grease (waste cooking oil and waste animal fats) is fast emerging as a promising alternative to address the twin challenges before the biodiesel industry today-fluctuation in prices of vegetable oil and the food versus fuel debate. Yellow grease has a high percentage of free fatty acids (FFA) and proves to be an unsuitable feedstock for biodiesel production from commercially viable alkali-catalyzed production systems due to saponification problems.“Green” methodologies based on heterogeneous solid acid catalyzed reactions have the potential to simultaneously promote esterification and transesterification reactions of yellow grease to produce biodiesel without soap formation and offer easy catalyst separation without generation of toxic streams. This paper presents kinetic studies for the conversion of model yellow grease feeds to biodiesel using a heteropolyacid supported on alumina (HSiW/Al2O3) using a batch autoclave. Three model yellow grease feeds were prepared using canola oil with added FFA such as palmitic, oleic and linoleic acid. A pseudo homogeneous kinetic model for the parallel esterification and transesterification was developed. The rate constants and activation parameters for esterification and transesterification reactions for the model yellow grease feeds were determined. The rate constants for esterification are higher than the transesterification rate constants. The kinetic model was validated using the experimental biodiesel data obtained from processing a commercial yellow grease feed. The kinetic model could be used to design novel processes to convert various low-value waste oils, fats and non-food grade oils to sustainable biodiesel. Keywords: Yellow grease, Canola oil, Free fatty acids, Heteropolyacid, Kinetics for esterification and transesterification
Green Energy & E... arrow_drop_down Green Energy & EnvironmentArticle . 2019 . Peer-reviewedLicense: CC BY NC NDData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.gee.2019.03.004&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 72 citations 72 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Green Energy & E... arrow_drop_down Green Energy & EnvironmentArticle . 2019 . Peer-reviewedLicense: CC BY NC NDData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.gee.2019.03.004&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2017Publisher:Elsevier BV Funded by:NSERCNSERCChunbao (Charles) Xu; Chunbao (Charles) Xu; Shanghuan Feng; Gang Chen; An Li; Zhongshun Yuan; Takashi Kuboki; Tao Shui; Hengfu Shui;Abstract In this study, crude cellulose derived from cornstalk, after bleaching, was used as raw material for the synthesis of sodium carboxymethyl cellulose (CMC) by reacting with the cellulose with NaOH and chloroacetic acid at 75 °C for 1.5 h. Effects of alkali dosage, concentration of chloroacetic acid on the physical and chemical properties of the CMC products were investigated. It was revealed that the reactants alkali reagent/chloroacetic acid/cellulose at the molar ratio of 4.6:2.8:1and 4:2.5:1, or at the molar ratio of NaOH/ClCH 2 COOH ≈1.6–1.64, resulted in CMC products of relatively high water solubility. The viscosity-average molecular weight M v of these two CMC products obtained at molar ratios of 4.0:2.5:1 and 4.6:2.8:1 is in the range of 1.94 × 10 4 –2.48 × 10 4 g mol −1 , and the average DS of the two products are 0.57 and 0.85, respectively. As the solute concentration is above 2 wt%, the viscosity of the CMC-water solution exhibits nonlinear (exponential) increasing with increasing the solute concentration (typical of non-Newton fluids).
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2017.06.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 74 citations 74 popularity Top 1% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2017.06.016&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2021Publisher:Wiley Miyuki Sakakura; Yasuhiro Suzuki; Takayuki Yamamoto; Yuta Yamamoto; Munekazu Motoyama; Yasutoshi Iriyama;Interfacial resistance at electrode‐high Li+ conductive solid electrolytes must be reduced well to develop high‐power all‐solid‐state batteries using oxide‐based solid electrolytes (Ox‐SSBs). Herein, crystalline electrode films of LiCoO2 (LCO) are formed on a high Li+ conductive crystalline‐glass solid electrolyte sheet, Li1.3Al0.3Ti2(PO4)3 (LATP) (σ25 °C = 1 × 10−4 S cm−1), at room temperature by aerosol deposition (AD), and the effects of the annealing temperature on the interfacial resistivities (Rint) at the LCO/LATP are investigated. The Rint visibly increases by annealing over 500 °C with the growth of Co3O4 as a reactant. In contrast, Rint is reduced to ≈100 Ω cm2 by low‐temperature annealing at 250–350 °C due to superior contact through the structural rearrangement of an artificial metastable interface formed by the AD. These results are applied to bulk‐type Ox‐SSB, Li/Li7La3Zr2O12(LLZ)/LCO–LATP, and our best Ox‐SSB delivers a discharge capacity of 100 mA cm−2 at 100 °C.
Energy Technology arrow_drop_down Energy TechnologyArticle . 2021 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/ente.202001059&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 12 citations 12 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Energy Technology arrow_drop_down Energy TechnologyArticle . 2021 . Peer-reviewedLicense: Wiley Online Library User AgreementData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1002/ente.202001059&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:MDPI AG Xingbo Yao; Bart J. Dewancker; Yuang Guo; Shuo Han; Juan Xu;doi: 10.3390/su12208687
China’s research on and specific implementation of energy saving for buildings are mainly concentrated in urban areas, but according to 2016 statistics, the rural population accounts for 42.65% of the total population, so rural housing has considerable energy-saving potential. However, the degree of attention to the energy consumption of rural houses needs to be improved. Regarding the research on and implementation of passive energy-saving strategies for residences, compared with centralized urban high-rise residences, rural residences mainly have independent courtyards, with a flexible layout and easier transformation. In this study, a system that uses the common cold lanes in traditional villages and buildings’ exterior walls was constructed, and the indoor spaces of courtyard buildings in southern Shaanxi were completely passively cooled in summer. This system can be completely separated from the supply of artificial energy by relying on the accumulation and buoyancy effects of air in patios and cold lanes and the hot-pressure ventilation in buildings to cool the buildings and greatly improve indoor ventilation efficiency. As the building is ventilated and cooled, the air wall formed in the system can effectively prevent direct contact between the outdoor and indoor temperatures and reduce the impact of thermal wall radiation on the interior. In previous studies on the passive design of courtyard houses, scholars considered the effect of thermal wall radiation on indoor temperature in simulations. Therefore, in this study, we also separately calculated whether to consider the difference between the situation with and without wall heat radiation (WHR) when simulating thermal conversion. The final results show that when the cooling system was adopted, the annual cooling load of the whole building was 4786.494 kW·h without WHR. However, with WHR, the cooling load reduction was 2989.128 kW·h, a difference of 1797.336 kW·h.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su12208687&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesgold 13 citations 13 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.3390/su12208687&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Elsevier BV Funded by:NSERCNSERCZhongshun Yuan; Hongwei Li; Hongwei Li; Chunbao (Charles) Xu; Qin Wei;Abstract Bio-based polyurethane (BPU) foams were successfully prepared using hydrothermally liquefied wheat straw (WS) to substitute a mass fraction of up to 50% of polyols. Response surface methodology (RSM) based on central composite design (CCD) was employed to optimize four process parameters: NCO/OH molar ratio, loading of crosslinking agent (glycerol), loading of catalyst (a mixture of triethylene diamine, stannous octoate, and triethanolamine), and loading of blowing agent (water) for the maximum compression strength of the rigid BPU foams. With the quadratic orthogonal regression model, verified by experimentation, the maximum compression strength of approximately 180 kPa was obtained at the following optimal conditions: NCO/OH molar ratio of 1.24:1, glycerol addition of 12.11%, catalyst loading of 0.76%, and blowing agent addition of 1.31% in relation to the total mass of polyols. The BPU foam prepared at the optimal conditions exhibits good thermal conductivity (0.045 Wm−1K−1) and thermal stability, comparable to those of a reference foam prepared with 100% PPG400.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2018.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 41 citations 41 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.biombioe.2018.02.011&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Preprint , Journal , Other literature type 2016Embargo end date: 01 Jan 2016Publisher:Institute of Electrical and Electronics Engineers (IEEE) Funded by:NSF | CPS: Medium: Collaborativ..., NSERCNSF| CPS: Medium: Collaborative Research: The Cyber-Physical Challenges of Transient Stability and Security in Power Grids ,NSERCAuthors: John W. Simpson-Porco; Francesco Bullo;arXiv: 1602.05632
The assessment of voltage stability margins is a promising direction for wide-area monitoring systems. Accurate monitoring architectures for long-term voltage instability are typically centralized and lack scalability, while completely decentralized approaches relying on local measurements tend towards inaccuracy. Here we present distributed linear algorithms for the online computation of voltage collapse sensitivity indices. The computations are collectively performed by processors embedded at each bus in the smart grid, using synchronized phasor measurements and communication of voltage phasors between neighboring buses. Our algorithms provably converge to the proper index values, as would be calculated using centralized information, but but do not require any central decision maker for coordination. Modifications of the algorithms to account for generator reactive power limits are discussed. We illustrate the effectiveness of our designs with a case study of the New England 39 bus system. 10 pages, submitted for publication
IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallIEEE Transactions on Smart GridArticle . 2016 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefhttps://dx.doi.org/10.48550/ar...Article . 2016License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tsg.2016.2533319&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen hybrid 41 citations 41 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert IEEE Transactions on... arrow_drop_down IEEE Transactions on Smart GridArticleLicense: publisher-specific, author manuscriptData sources: UnpayWallIEEE Transactions on Smart GridArticle . 2016 . Peer-reviewedLicense: IEEE CopyrightData sources: Crossrefhttps://dx.doi.org/10.48550/ar...Article . 2016License: arXiv Non-Exclusive DistributionData sources: Dataciteadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1109/tsg.2016.2533319&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018 AustraliaPublisher:Elsevier BV El-Bidairi, Kutaiba S; Duc Nguyen, Hung; Jayasinghe, S.D.G; Mahmoud, Thair S; Penesis, Irene;Microgrids are increasingly being used as a platform to integrate distributed generation such as renewable energy sources and (RESs) conventional sources in both grid-connected and isolated power systems. Due to the inherent intermittent nature of RESs, energy storage systems (ESSs) that can absorb fluctuations have become inevitable. Nevertheless, large capacities of ESSs increase the initial cost while small capacities lead to instabilities and increase in the cost of conventional fuels. Therefore, finding the optimal size of the ESS for a given application is essential for the reliable, efficient and economical operation of a microgrid. Once the battery size is decided, maintaining its energy at appropriate levels is essential to ensure stable and safe operation of the microgrid. This paper presents a novel expert fuzzy system - grey wolf optimization (FL-GWO) based intelligent meta-heuristic method for battery sizing and energy management. The proposed energy management operation is carried out by a Grey Wolf Optimiser (GWO) that is helped to set the membership functions and rules of the fuzzy logic expert system. The unit commitment (UC) issue, which is essential for the proper operation of the isolated microgrid, has been additionally considered in this paper. To verify the performance of the proposed method, results are compared with the rules-based method and traditional GWO algorithm. It has been proven from the results that the FL-GWO has a significant convergence property and capability to minimize the Levelized Cost Of Electricity (LCOE) by 14.13% and 24.15% compared with conventional GWO algorithm and rules-based method, respectively. The weather conditions for different climates is used to verify the performance of the intelligent energy management method under different operating scenarios. The results show that the intelligent online multi-objective energy management strategy is capable of managing a smooth power flow with the same optimal configuration in the isolated microgrid, minimising the fossil fuel utilisation and reducing the CO2 emission level.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversity of Tasmania: UTas ePrintsArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)Edith Cowan University (ECU, Australia): Research OnlineArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 115 citations 115 popularity Top 1% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: CrossrefUniversity of Tasmania: UTas ePrintsArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)Edith Cowan University (ECU, Australia): Research OnlineArticle . 2018Data sources: Bielefeld Academic Search Engine (BASE)add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.076&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2018Publisher:Elsevier BV Beibei Xu; Pengcheng Guo; Diyi Chen; Diyi Chen; Xingqi Luo; Paul Behrens; Wei Ye;Abstract Global hydropower growth continues to accelerate with 25% of total capacity installed in just the last 10 years. This accelerating expansion and the important storage facility hydropower means it is increasingly important to understand the reasons for operational failures. This is a challenge because the major reason for failures involves the complex interaction of hydraulic, mechanical and electric subsystems. Historically, reliability modelling has been split in two directions, focusing on different sub-systems, and has not yet been unified. Here these approaches are unified with a novel expression of unbalanced forces. This model with operational data are validated and the important modes of oscillation in the shaft are identified. Finally, the mechanism of the first-order oscillation mode exciting a second-order mode is presented. This integrated and accurate mathematical model is a major advance in the diagnosis and prediction of failures in hydropower operation.
Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.034&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen bronze 52 citations 52 popularity Top 10% influence Top 10% impulse Top 1% Powered by BIP!
more_vert Energy Conversion an... arrow_drop_down Energy Conversion and ManagementArticle . 2018 . Peer-reviewedLicense: Elsevier TDMData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.enconman.2018.08.034&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2020Publisher:Elsevier BV Authors: Ismail Adal Guiamel; Han Soo Lee;This study aims to identify potential hydropower sites and calculate the theoretical potential hydropower capacity based on watershed modelling of the Mindanao River Basin (MRB) in the Philippines for the sustainable development of a previously unstudied region. The Soil and Water Assessment Tool (SWAT) was applied to delineate the watershed of the MRB and simulate the river discharges with inputs from observed precipitation and global gridded precipitation datasets. Observed weather data, such as temperature, humidity, and solar radiation, from four meteorological stations in the Philippines were also used as inputs for SWAT modelling. Simulated discharges were calibrated at three river gauges on the Nituan, Libungan and Pulangi Rivers. However, due to limited river discharge records, model validations were conducted in proxy basins: the calibrated model parameters in river A were used in the watershed modelling of proxy river B. Of the delineated 107 sub-basins in the MRB watershed, only 33 were identified as having potential sites for hydropower development. These potential sub-basins hosted a total of 154 potential sites with an estimated monthly average power capacity of 5,551.35 MW for all 33 sub-basins. The estimated theoretical power capacity of 15,266.22 MW for all sites in the MRB is approximately equivalent to the Philippines’ total available power capacity in 2017 of 15,393 MW. These sites were classified into 16 mini-scale hydropower sites, 114 small-scale hydropower sites and 24 medium-scale hydropower sites based on the simulated river discharges and potential power capacities. Based on these results, hydropower development could be an alternative to strengthen the exploration of renewable energy resources and improve the energy situation in Mindanao; hydropower development could also have mitigation effects on frequent floods in flat, low-lying downstream areas.
add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.egyr.2020.04.025&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess RoutesGreen gold 18 citations 18 popularity Top 10% influence Top 10% impulse Top 10% Powered by BIP!
more_vert add ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1016/j.egyr.2020.04.025&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eudescription Publicationkeyboard_double_arrow_right Article , Journal 2019Publisher:Royal Society of Chemistry (RSC) Jia Li; Lixun Cheng; Fei Wang; Li Li; Yanming Wang; Song Dai; Yongxing Zhang; Xin-Yao Yu; Xin-Yao Yu;doi: 10.1039/c9se00770a
Mixed transition metal oxides with high theoretical capacity show great potential to replace carbonaceous anode materials in lithium-ion batteries.
Sustainable Energy &... arrow_drop_down Sustainable Energy & FuelsArticle . 2019 . Peer-reviewedLicense: Royal Society of Chemistry Licence to PublishData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1039/c9se00770a&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.euAccess Routesbronze 9 citations 9 popularity Top 10% influence Average impulse Top 10% Powered by BIP!
more_vert Sustainable Energy &... arrow_drop_down Sustainable Energy & FuelsArticle . 2019 . Peer-reviewedLicense: Royal Society of Chemistry Licence to PublishData sources: Crossrefadd ClaimPlease grant OpenAIRE to access and update your ORCID works.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.This Research product is the result of merged Research products in OpenAIRE.
You have already added works in your ORCID record related to the merged Research product.All Research productsarrow_drop_down <script type="text/javascript"> <!-- document.write('<div id="oa_widget"></div>'); document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=10.1039/c9se00770a&type=result"></script>'); --> </script>
For further information contact us at helpdesk@openaire.eu