Performance Analysis on Hybrid System of Thermosyphon free Cooling and Vapor Compression Refrigeration for Data Centers in Different Climate Zones of China

AbstractFree cooling is one of the most potential ways of reducing the energy consumption of data centers. Thermosyphon has superior heat transferability thus it is suitable for application in free cooling. However, a separate thermosyphon free cooling system usually cannot provide sufficient cooling capacity in warm seasons. In order to overcome this weakness and avoid two sets of equipment, hybrid system of thermosyphon free cooling and vapor compression refrigeration for data centers has been developed by researchers. The cooling performance of this kind of system depends greatly on the climate outside therefore its applicability in different time and zones needs to be studied. In this paper, the climate data from five cities of different climate zones in China is collected. The performance model of the hybrid system is built up. Based on the climate data and performance model, the annual energy consumption is then calculated and compared with traditional air conditioner. The result shows that the energy-saving potential of the hybrid system varies in different climate zones, and when the mode switching temperature is relatively high, it is distinct in most climate zones of China.
- Chinese Academy of Sciences China (People's Republic of)
- Technical Institute of Physics and Chemistry China (People's Republic of)
- Chinese Academy of Sciences China (People's Republic of)
- University of Chinese Academy of Sciences China (People's Republic of)
Thermosyphon, Free cooling, Energy consumption, Energy(all), Climate zone, Data center
Thermosyphon, Free cooling, Energy consumption, Energy(all), Climate zone, Data center
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).9 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Average