You have already added 0 works in your ORCID record related to the merged Research product.
You have already added 0 works in your ORCID record related to the merged Research product.
<script type="text/javascript">
<!--
document.write('<div id="oa_widget"></div>');
document.write('<script type="text/javascript" src="https://beta.openaire.eu/index.php?option=com_openaire&view=widget&format=raw&projectId=undefined&type=result"></script>');
-->
</script>
A spatiotemporal indirect evaporative cooler enabled by transiently interceding water mist

handle: 10754/666362
The building sector consumes around half of the global energy produced and air-conditioning processes guzzle over 55% of building sector energy. The conventional refrigerant-based chillers, covering over 90% of the current cooling market, are not only energy-intensive but also have high ozone depletion and global warming potentials. Indirect evaporative coolers were introduced but they were difficult to commercialize due to their practical lower achievable temperature limits. All existing indirect evaporative coolers use hydrophilic interface to provide wet surfaces for evaporative potential. These hydrophilic surfaces not only increase heat transfer resistance but also provide excellent conditions, wet and damp surface, for mold formation. The treatment of mold is almost impossible as the height of the channel is only 3-5mm and the fungus can be dangerous to health. Therefore, we proposed an innovative indirect evaporative cooling cycle in which there are no hydrophilic surfaces inside the system. The humidification of the working air is carried out before it is introduced into the wet channel. Also, the interface between dry and wet channel is only a thin aluminium foil that boosts heat transfer from supply air to working air in the transverse direction. A generic cell of 1800mm long and 280mm wide can produce 182.5watt cooling capacity. The measured coefficient of performance and effectiveness are 45 and 80% respectively for sensible cooling. This basic information of the proposed innovative indirect evaporative cooling system can be used to design a commercial unit as the total capacity is based on number of generic cells.
- Northumbria University United Kingdom
- King Abdullah University of Science and Technology Saudi Arabia
- Texas A&M University – Kingsville United States
- The University of Texas System United States
- Bahauddin Zakariya University Pakistan
H800
H800
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).54 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 1% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Top 10% impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 1%