Improving Energy Efficiency by Utilizing Wetted Cellulose Pads in Passive Cooling Systems
doi: 10.3390/en15010369
The effectiveness of using wetted cellulose pads on improving the performance of two conventional passive cooling systems has been evaluated. First, an experimental design was developed to determine the impact of using a wetted cellulose pad on the temperature and velocity of the airflow. A cellulose pad (7090 model) with a cross-sectional area of 0.5 × 0.5 m2 and three different thicknesses of 10, 15, and 30 cm were selected and tested. The results indicated that using wetted cellulose pads with thicknesses ranging from 10–30 cm decreased the outlet airflow temperature from 11.3 to 13.7 °C on average. For free airflow at velocity 3.5 m/s, the outlet airflow velocity from the wetted cellulose pad decreased to 0.9, 0.7 and 0.6 m/s, respectively, for cellulose pads with thicknesses of 10, 15, and 30 cm. By applying experimental results on a psychrometric chart, the humidity ratio of outlet airflow was obtained between 40–70%. The study established airflow velocity as the critical parameter in passive cooling systems. With the novel concept of combining wetted cellulose pads for passive cooling systems (i.e., wind catchers and induced ventilation), there is good potential to reduce the energy requirements for thermal comfort in buildings in regions with a hot and arid climate.
- University of Waterloo Canada
- K.N.Toosi University of Technology Iran (Islamic Republic of)
Technology, T, natural ventilation; passive cooling system; cellulose pad; wind energy; wind catcher; induced ventilation, natural ventilation, induced ventilation, wind energy, passive cooling system, wind catcher, cellulose pad
Technology, T, natural ventilation; passive cooling system; cellulose pad; wind energy; wind catcher; induced ventilation, natural ventilation, induced ventilation, wind energy, passive cooling system, wind catcher, cellulose pad
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).6 popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.Top 10% influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).Average impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.Top 10%